959 Terry Street
Eugene, Oregon 97402
Telephone: (541) 683-5700
Fax: (541) 345-7140
An Unpublished Work - All rights reserved. No part of the contents of this documentation or the procedures
described therein may be reproduced or transmitted in any form or by any means without prior written permission of
Datalogic Scanning, Inc. or its subsidiaries or affiliates ("Datalogic" or “Datalogic Scanning”). Owners of Datalogic
products are hereby granted a non-exclusive, revocable license to reproduce and transmit this documentation for the
purchaser's own internal business purposes. Purchaser shall not remove or alter any proprietary notices, including
copyright notices, contained in this documentation and shall ensure that all notices appear on any reproductions of
the documentation.
Should future revisions of this manual be published, you can acquire printed versions by contacting your Datalogic
representative. Electronic versions may either be downloadable from the Datalogic website (www.scanning.datalogic.com) or provided on appropriate media. If you visit our website and would like to make comments or suggestions about this or other Datalogic publications, please let us know via the "Contact Datalogic" page.
Disclaimer
Datalogic has taken reasonable measures to provide information in this manual that is complete and accurate, however, Datalogic reserves the right to change any specification at any time without prior notice.
Datalogic is a registered trademark of Datalogic S.p.A. and the Datalogic logo is a trademark of Datalogic S.p.A. all
licensed to Datalogic Scanning, Inc. All other trademarks and trade names referred to herein are property of their
respective owners.
This product may be covered by one or more of the following patents: 4603262 • 4639606 • 4652750 • 4672215 • 4699447 •
4709369 • 4749879 • 4786798 • 4792666 • 4794240 • 4798943 • 4799164 • 4820911 • 4845349 • 4861972 • 4861973 • 4866257
The Magellan®1000i Omni-Directional Imaging Scanner offers hands-free scanning for small,
easily handled items and handheld scanning for bulkier items. Its aggressive imaging performance and intuitive operation reduces user training and speeds checkout for better customer
service.
About This Manual
This manual presents advanced user information which includes connection, programming,
product and cable specifications, and other useful references. For additional information, such
as installation, maintenance, troubleshooting and warranty information, see the Quick Reference Guide (QRG). Copies of other publications for this product are downloadable free of
charge from the website listed on the back cover of this manual.
On leaving the factory, units are programmed for the most common terminal and communications settings. If you need to change these settings, custom programming can be accomplished
by scanning the bar codes in this guide.
Chapter 1
Getting Started
Bold text and a yellow-highlighted background indicates the most common default setting for a
feature/option.
Manual Conventions
The symbols listed below are used in this manual to notify the reader of key issues or procedures
that must be observed when using the scanner:
NOTE
CAUTION
Notes contain information necessary for properly diagnosing, repairing and operating the
scanner.
The CAUTION symbol advises you of actions
that could damage equipment or property.
Product Reference Guide
1-1
Getting Started
Connecting the Scanner
The scanner kit you ordered to match your interface should provide a compatible cable for your
installation. Use the appropriate instructions below to connect the scanner to the terminal, PC
or other host device.
Upon completing the connection via the appropriate interface instructions below, proceed to
Interface Related Features section of this manual and scan the bar code to select the correct
the
interface type.
RS-232 Serial Connection —
to the terminal/PC serial port via the RS-232 cable as shown in
Turn off power to the terminal/PC and connect the scanner
Figure 1. If the terminal will not
support POT (Power Off the Terminal) to supply scanner power, use the approved power supply
(AC Adapter). Plug the AC Adapter barrel connector into the socket on the RS-232 cable connector and the AC Adapter plug into a standard power outlet.
Figure 1
USB Connection —
USB cable for the interface type you ordered. Reference
. RS-232 Serial or USB Connection using A/C Adapter
I/F Cable
To Host/Terminal
Connect
Here
A/C Adapter
(if needed)
Connect the scanner to a USB port on the terminal/PC using the correct
Figure 1 and Figure 2.
USB installations may require a power connection via
NOTE
an approved A/C Adapter as shown in
example, this would be the case if the scanner is connected along with a number of other devices to a nonpowered USB hub.
Figure 1. For
For 220-230 VAC
adapters, the
cord must be
facing down as
shown in the
illustration. If
installed upwards,
it will pose an
undue strain on the
socket outlet.
Figure 2. Other Connection Types
1-2Magellan
or...
or...
B
S
K
U
e
y
W
b
o
e
a
d
r
or...
d
g
e
®
1000i
d
n
a
W
M
B
I
Programming
Wand Emulation Connection —
Connect the scanner to the appropriated port on the ter-
minal/PC using the correct cable for the interface type you ordered. Reference
IBM Connection —
rect IBM cable. Reference
Keyboard Wedge Connection —
Connect the scanner to the IBM port on the terminal/PC using the cor-
Figure 2.
Before connection, turn off power to the terminal/PC.
The Keyboard Wedge cable has a ‘Y’ connection from the scanner. Connect the female to the
male end from the keyboard and the remaining end at the keyboard port at the terminal/PC.
Reference
Figure 2.
Programming
The scanner is typically factory-configured with a set of default features standard to the interface
type you ordered. After scanning the interface bar code from the
tion, you can select other options and customize your scanner through use of the instructions
and programming bar codes available in that section and also the
chapters of this manual.
Using the Programming Bar Codes
This manual contains feature descriptions and bar codes which allow you to reconfigure your
scanner. Some programming bar code labels, like the label below for resetting defaults, require
only the scan of that single label to enact the change. Most of the programming labels in this
manual, however, require the scanner to be placed in Programming Mode prior to scanning
them. Scan a START/END bar code once to enterProgramming Mode. Once the scanner is in
Programming Mode, you can scan a number of parameter settings before scanning the START/
END bar code a second time, which will then accept your changes, exit Programming Mode
and return the scanner to normal operation.
Figure 2.
Interface Related Features sec-
Data Editing and Symbologies
Resetting the Standard Product Defaults
If you are unsure of what programming options are in your scanner, or you’ve changed some
options and want the factory settings restored, scan the Standard Product Default Settings bar
code below. This will copy the factory configuration for the currently active interface to the current configuration.
Standard Product Default Settings
The programming section lists the factory default settings for each of the menu commands for
the standard RS-232 interface in
tings for the other interfaces can be found in
Product Reference Guide
BOLD text on the following pages. Exceptions to default set-
Appendix D, Default Settings.
1-3
Getting Started
LED and Beeper Indicators
The scanner’s beeper sounds and its green LED illuminates to indicate various functions
or errors on the scanner. The tables below list these indications. One exception to the
behaviors listed in the tables is that the scanner’s functions are programmable, and may
or may not be turned on. For example, certain indications, such as the power-up beep
can be disabled using programming bar code labels.
Green LED Indications
LED
INDICATION
Power-on
indication
Good Read
Indication
Scanner ReadyConstant dim greenThe scanner is ready for operation.
Sleep Mode
Host Disable
Diagnostics
BEEPER FUNCTIONS
BEEPER
INDICATION
Bright green flash
Bright green flashIndicates a bar code has been read and decoded.
Constant green flash
(100mS on, 1900mS off)
Constant green flash at 1 Hz
(100mS on, 900mS off)
Varies (see "Error Codes" on
page 1-5 for more information)
INDICATIONCOMMENT
Indicates the scanner has finished all its power up tests and is
now ready for ooperation.
The scanner is in Sleep Mode. To wake the scanner up, move
an object in front of its window or press the button atop the
unit.
The scanner is disabled due to receiving a disble command
from the POS terminal.
The LED can provide diagnostic feedback if the scanner discovers a problem during SelfTest.
INDICATIONCOMMENT
The Power-On LED indication is a configurable feature which
Power On BeepSingle beep
Good Read
Indication
Diagnostics
Programming
Mode
Indications
1-4Magellan
Single beep
Varies (see "Error Codes" on
page 1-5 for more information)
Varies (see the Product Reference
Guide for more information about
scanner programming)
can be enabled or disabled. When enabled, this beep Indicates the scanner has finished all its power up tests and is
now ready for operation.
The good read beep indication is configurable. Options
include: Enable/disable, frequency, duration and volume. See
the Product Reference Guide (PRG) for more information.
The Beeper can provide diagnostic feedback if the scanner
discovers a problem during SelfTest.
The Beeper will sound as programming bar code labels are
scanned, indicating progress during scanner configuration.
®
1000i
Error Codes
Upon startup, if the scanner flashes its indicator LED or sounds an unexpected series of beep
tones (other than normal power-up indications), this means the scanner has not passed its automatic Selftest and has entered FRU
pulled, the sequence will be repeated. The following table describes the LED flashes/beep codes
associated with an error found.
NUMBER OF
LED FLASHES/
ERRORCORRECTIVE ACTION
BEEPS
1Configuration
2Interface PCB
6Main PCB
10Button Error
12Imager Module
Error Codes
1
isolation mode. If the scanner is reset or the trigger is
Contact Helpdesk for assistance
13
14
Software ID
Failure
CPLD/Code
Mismatch
1. Field Replaceable Unit (FRU)
Product Reference Guide
1-5
Getting Started
NOTES
1-6Magellan
®
1000i
Double Read Timeout
The Double Read Timeout feature sets a time limit that determines how much time must pass
before reading the same label again (e.g. two identical items in succession).
0.1 Second
Chapter 2
General Features
START / END
PROGRAMMING BARCODES
0.3 Second
0.5 Second
0.2 Second
0.4 Second
DEFAULT
0.6 Second
Product Reference Guide
2-1
General Features
Double Read Timeout — cont.
PROGRAMMING BARCODES
0.7 Second
0.9 Second
START / END
0.8 Second
1 Second
2-2Magellan
®
1000i
Label Gone Timeout
Label Gone Timeout
This feature sets the time after the last label segment is seen before the scanner prepares for a
new label.
START / END
PROGRAMMING BARCODES
Sets the label gone timeout duration using hex values from 000 to 255 in increments of ten milliseconds (10ms or 0.01 seconds). To
configure this feature, scan the “START/END” bar code above to place the unit in Programming Mode, then the “Set Label Gone Tim-
eout,” followed by the three digits (zero padded) from the Alphanumeric table in
desired time value. Exit programming mode by scanning the “START/END” bar code again.
DEFAULT SETTING FOR THIS FEATURE: 320 milliseconds (032)
Appendix C, Alpha-Numeric Pad representing the
Set Label Gone Timeout
Productivity Index Reporting (PIR)
When PIR is enabled, label quality data is appended to decoded data before being presented to
the POS. The PIR feature allows the scanner to provide information to an external computer,
indicating how easy the label was to read.
This value-added feature is a factory-programmed
option. Contact your dealer for information about
upgrading your system to include this advanced
NOTE
Disable
DEFAULT
capability.
PROGRAMMING BARCODES
START / END
Product Reference Guide
Enable
2-3
General Features
Sleep Mode
This feature specifies the amount of time with no bar code reads before the scanner enters sleep mode.
START / END
PROGRAMMING BARCODES
15 Seconds
30 Seconds
1 Minute
3 Minutes
5 Minutes
2 Minutes
4 Minutes
2-4Magellan
®
1000i
Sleep Mode — cont.
START / END
7 Minutes
Sleep Mode
PROGRAMMING BARCODES
6 Minutes
8 Minutes
9 Minutes
12 Minutes
30 Minutes
10 Minutes
DEFAULT
15 Minutes
1 Hour
Product Reference Guide
2-5
General Features
LED and Beeper Indicators
Power On Alert
Disables or enables the indication (a single beep) that the scanner has finished all its power up
tests and is now ready for operation.
PROGRAMMING BARCODES
Disable
START / END
Enable
DEFAULT
2-6Magellan
®
1000i
Good Read: When to Indicate
This feature specifies when the scanner will provide indication (beep and/or flash its green LED)
upon successfully reading a bar code. Choices are:
•Good Read = Indicate after decode
•Good Read = Indicate after transmit
•Good Read = Indicate after CTS goes inactive, then active
This option (Indicate after CTS goes inactive, then
active), which uses CTS, is only valid for RS-232 interfaces.
NOTE
PROGRAMMING BARCODES
LED and Beeper Indicators
START / END
After Decode
DEFAULT
After CTS goes inactive, then active
After Transmit
Product Reference Guide
2-7
General Features
Good Read Beep Control
This feature enables/disables the scanner’s ability to beep upon a successful decode of a bar code.
Disable
START / END
PROGRAMMING BARCODES
Enable
DEFAULT
Good Read Beep Frequency
Adjusts the good read beep to sound at a selectable low, medium or high frequency, selectable
from the list below. (Controls the beeper’s pitch/tone.)
PROGRAMMING BARCODES
Low
High
START / END
Medium
DEFAULT
2-8Magellan
®
1000i
Good Read Beep Length
Specifies the duration of a good read beep.
60msec
100msec
LED and Beeper Indicators
START / END
PROGRAMMING BARCODES
80msec
DEFAULT
140msec
180msec
120msec
160msec
200msec
Product Reference Guide
2-9
General Features
Good Read Beep Volume
Selects the beeper volume (loudness) upon a good read beep. There are three selectable volume
levels.
Low
High
DEFAULT
START / END
PROGRAMMING BARCODES
Medium
2-10Magellan
®
1000i
Scanning Features
Targeted Scanning Mode
Upon pressing the button, the scanner will project an aiming pattern to assist in centering over
the bar code. Scanning then takes place as soon as the button is released.
NOTE
Configuration options for Targeted Scanning Mode are:
•Target Mode Active Time
When add-ons are enabled and a bar code is being
read while in Targeted Mode, position the pointer
at or near the end of the base label to ensure the
scanner will read both the base and add-on label.
Targeted Scanning Mode will read bar codes in any
orientation.
The scanner will return to full pattern Omni-directional Mode after
elapsed.
Target Mode Active Time has
Scanning Features
•Target Mode Linger Time
Target Mode Active Time
Specifies the time duration the scanner attempts to decode labels while in the targeted mode of
operation.
PROGRAMMING BARCODES
Extra Short Duration
Medium Duration
DEFAULT
START / END
Short Duration
Product Reference Guide
Long Duration
2-11
General Features
Target Mode Linger Time
Specifies the time duration the scanner remains in the targeted mode of operation after reading
a bar code before reverting to Omni-directional Mode.
START / END
PROGRAMMING BARCODES
Medium Duration
DEFAULT
Short Duration
Long Duration
2-12Magellan
®
1000i
Wake Up Intensity
This feature indicates the percentage of ambient light change which will trigger the scanner to
wake up from Sleep Mode. Lower settings provide greater sensitivity. The seelectable range for
this setting is 5% to 15%.
5%
Scanning Features
START / END
PROGRAMMING BARCODES
6%
7%
9%
11%
8%
10%
DEFAULT
Product Reference Guide
12%
2-13
General Features
Wake Up Intensity — cont.
PROGRAMMING BARCODES
13%
15%
START / END
14%
2-14Magellan
®
1000i
Chapter 3
Interface Related Features
At the time of this writing, the Scanner supports the interfaces listed in Ta b le 3 - 1. Select the
desired interface type from the table, then reference the page number given for the customizable
features section associated with each interface. See
Wedge interface type (A through Y as listed).
Table 3-1. Interfaces Supported
RS-232PageKeyboard WedgePage
RS-232 Standard
RS-232 Wincor-Nixdorf
IBM
IBM 4683 Port 5B
IBM 4683 Port 9B
IBM 4683 Port 17
USB
IBM USB
USB Keyboard
Wand Emulation
Wand Emulation3-26
Keyboard Wedge3-30
Keyboard Wedge A
Keyboard Wedge B
Keyboard Wedge C
Keyboard Wedge D
Keyboard Wedge E
Keyboard Wedge F
Keyboard Wedge G
a. Consult Ta bl e for more information regarding keyboard interface types.
a
a
a
a
a
a
a
3-9
3-9
3-24
3-24
3-24
3-24
3-24
3-30
3-30
3-30
3-30
3-30
3-30
3-30
Keyboard Wedge H
Keyboard Wedge I
Keyboard Wedge J
Keyboard Wedge K
Keyboard Wedge L
Keyboard Wedge M
Keyboard Wedge N
Keyboard Wedge N
Keyboard Wedge O
Keyboard Wedge P
Keyboard Wedge Q
Keyboard Wedge R
Keyboard Wedge S
Keyboard Wedge T
Keyboard Wedge U
Keyboard Wedge V
Keyboard Wedge W
Keyboard Wedge X
Keyboard Wedge Y
Ta bl e 3 -2 for a description of each Keyboard
a
a
3-30
a
3-30
a
3-30
a
3-30
a
3-30
a
3-30
a
3-30
a
3-30
a
3-30
a
3-30
a
3-30
a
3-30
a
3-30
a
3-30
a
3-30
a
3-30
a
3-30
a
3-30
NOTE
Product Reference Guide
The correct interface cable is included for the scanner
interface type you ordered.
IBM 316X, 3179/3180/319X/3270
RIBM 3151/3152-010, 347X/348X
SDIGITAL VT 220/320/330/340/350/382
TDIGITAL VT420
UDIGITAL VT 510/520 IBM ANSI Style Keyboard
VDIGITAL VT 510/520 IBM PC Style Keyboard
WSUN SPARC 5/10
XSUN 420/440, ITX
YWYSE 370/355 Style Enhanced IBM PC
NOTE
3-2Magellan
Reference
pings for more information about keyboards.
Appendix E, Keyboard Function Key Map-
®
1000i
Interface Selection
START / END
RS-232 Wincor-Nixdorf
Interface Selection
PROGRAMMING BARCODES
RS-232 Standard
IBM 4683 Port 5B
IBM 4683 Port 9B
IBM USB
Wand Emulation
IBM 4683 Port 17
USB Keyboard
Product Reference Guide
Keyboard Wedge A
3-3
Interface Related Features
Interface Selection — cont.
START / END
PROGRAMMING BARCODES
Keyboard Wedge C
Keyboard Wedge B
Keyboard Wedge D
Keyboard Wedge E
Keyboard Wedge G
Keyboard Wedge I
Keyboard Wedge F
Keyboard Wedge H
3-4Magellan
Keyboard Wedge J
®
1000i
Interface Selection — cont.
PROGRAMMING BARCODES
Keyboard Wedge K
Keyboard Wedge M
Interface Selection
START / END
Keyboard Wedge L
Keyboard Wedge O
Keyboard Wedge Q
Keyboard Wedge S
Keyboard Wedge N
Keyboard Wedge P
Keyboard Wedge R
Product Reference Guide
3-5
Interface Related Features
Interface Selection — cont.
PROGRAMMING BARCODES
Keyboard Wedge T
Keyboard Wedge V
START / END
Keyboard Wedge U
Keyboard Wedge X
Keyboard Wedge W
Keyboard Wedge Y
3-6Magellan
®
1000i
Interface Features
Obey/Ignore Host Commands
When set to ignore host commands, the scanner will ignore all host commands except for the
minimum set necessary to keep the interface active and transmit labels For normal operation of
the interface, select Obey Host Commands.
START / END
Interface Features
PROGRAMMING BARCODES
Obey Host Commands
DEFAULT
Ignore Host Commands
Product Reference Guide
3-7
Interface Related Features
Interface Features — cont.
Host Transmission Buffers
Specifies the number of host transmission(s) that may be buffered. By buffering data from a bar
code, the scanner can continue to read a new bar code while the old one is being transmitted to
the host. Selecting BUFFERS = 1 means that the first bar code must be transmitted before a
new one can be read. A selection of BUFFERS = 2 means that a new bar code can be read while
data from the first bar code is transmitted.
When a DISABLE SCANNER command is received from the host, the scanner will continue to
transmit all data that is buffered.
START / END
PROGRAMMING BARCODES
Host Transmission Buffers = 1
Host Transmission Buffers = 2
DEFAULT
3-8Magellan
®
1000i
RS-232 Interface Features
START / END
PROGRAMMING BARCODES
2400 Baud
9600 Baud
DEFAULT
Interface Features
1200 Baud
4800 Baud
38400 Baud
115200 Baud
19200 Baud
57600 Baud
Product Reference Guide
3-9
Interface Related Features
RS-232 Interface Features — cont.
START / END
PROGRAMMING BARCODES
8 Data Bits
DEFAULT
7 Data Bits
1 Stop Bit
DEFAULT
2 Stop Bits
Parity = Even
Parity = None
DEFAULT
Parity = Odd
3-10Magellan
®
1000i
RS-232 Interface Features — cont.
Hardware Flow Control
Interface Features
Disable Hardware Control—
The scanner transmits to the host regardless of any activity on
the CTS line.
Enable CTS Flow Control—
Enable CTS Scan Control—
The CTS signal controls transmission of data to the host.
The CTS line must be active for the scanner to read and transmit data. While the CTS line is inactive, the scanner remains in a host-disabled state; following
a successful label transmission, the CTS signal must transition to inactive and then to active to
enable scanning for the next label.
START / END
PROGRAMMING BARCODES
Disable Hardware Control
DEFAULT
Enable CTS Flow Control
Enable CTS Scan Control
Product Reference Guide
3-11
Interface Related Features
RS-232 Interface Features — cont.
Intercharacter Delay
This delay is inserted after each data character transmitted. If the transmission speed is too high,
the system may not be able to receive all characters. You may need to adjust the delay to make
the system work properly.
START / END
PROGRAMMING BARCODES
Interchar Delay = 10 msec
Inter-Char Delay = No Delay
DEFAULT
Interchar Delay = 30 msec
Interchar Delay = 50 msec
Interchar Delay = 20 msec
Interchar Delay = 40 msec
Interchar Delay = 60 msec
Interchar Delay = 70 msec
3-12Magellan
®
1000i
Intercharacter Delay — cont.
START / END
PROGRAMMING BARCODES
Interchar Delay = 80 msec
Interchar Delay = 90 msec
Software Flow Control
Disables/Enables software control using XON/XOFF characters.
START / END
Interface Features
Enable Software Flow Control
PROGRAMMING BARCODES
Disable Software Flow Control
DEFAULT
Product Reference Guide
3-13
Interface Related Features
RS-232 Interface Features — cont.
Host Echo
When enabled, this feature passes all data through the scanner to the host as it comes in. This
feature is used for applications where “daisy chaining” of RS-232 devices onto the same cable is
necessary. If, for example, one of the devices in the chain is a terminal where someone is entering
data while another person is simultaneously scanning a bar code requiring transmission to the
host, the scanner will wait for the RS-232 channel to be quiet for a specified period of time (set
RS-232 Host Echo Quiet Interval). The scanner can be set to observe this delay before sending its
via
data in order to avoid RS-232 transmission conflicts.
START / END
PROGRAMMING BARCODES
Disable Host Echo
DEFAULT
Enable Host Echo
3-14Magellan
®
1000i
RS-232 Interface Features — cont.
Host Echo Quiet Interval
This setting specifies the time interval of RS-232 channel inactivity which must transpire before
the scanner will break the host echo loop to transmit the bar code data that has just been
scanned to the host.
START / END
PROGRAMMING BARCODES
Host Echo Quiet Interval = 10msec
DEFAULT
Interface Features
Host Echo Quiet Interval = 0msec
Host Echo Quiet Interval = 30msec
Host Echo Quiet Interval = 50msec
Host Echo Quiet Interval = 70msec
Host Echo Quiet Interval = 20msec
Host Echo Quiet Interval = 40msec
Host Echo Quiet Interval = 60msec
Product Reference Guide
3-15
Interface Related Features
Host Echo Quiet Interval — cont.
START / END
Host Echo Quiet Interval = 90msec
PROGRAMMING BARCODES
Host Echo Quiet Interval = 80msec
Host Echo Quiet Interval = 100msec
Signal Voltage: Normal/TTL
Specifies whether the RS-232 interface provides TTL levels on the output pins TxD and RTS.
START / END
PROGRAMMING BARCODES
Signal Voltage: Normal RS-232
DEFAULT
Signal Voltage: TTL
3-16Magellan
®
1000i
RS-232 Invert
Enables/disables inversion of RS-232 TXD and RXD signals.
START / END
PROGRAMMING BARCODES
Disable RS-232 Invert
Enable RS-232 Invert
Interface Features
DEFAULT
Beep on ASCII BEL
Enables/disables ability of scanner to beep (sound a good read tone) on receiving an ASCII BEL
(07 hex).
START / END
PROGRAMMING BARCODES
Enable Beep on ASCII BEL
DEFAULT
Disable Beep on ASCII BEL
Product Reference Guide
3-17
Interface Related Features
Beep on Not on File
Select for the host to beep (or not) when a not-on-file (host command) condition is detected by
the host.
START / END
Enable Beep on Not On File
DEFAULT
PROGRAMMING BARCODES
Disable Beep on Not On File
3-18Magellan
®
1000i
Interface Features
ACK NAK Options
This enables/disables the ability of the scanner to support the RS-232 ACK/NAK protocol.
When configured, the scanner and/or host sends an “ACK” when it receives data properly, and
sends “NAK” when the data is in error. Selections for this option are:
•Disable
•Enable for label transmission — the scanner expects an ACK/NAK response from the host
when a label is sent
•Enable for host-command acknowledge — the scanner will respond with ACK/NAK
when the host sends a command
•Enable for label transmission and host-command acknowledge
START / END
PROGRAMMING BARCODES
Enable ACK NAK for Transmission
Enable ACK NAK for transmission and host command
Disable ACK NAK
DEFAULT
Enable ACK NAK for host command acknowledge
Product Reference Guide
3-19
Interface Related Features
RS-232 Interface Features — cont. — cont.
ACK Character
START / END
PROGRAMMING BARCODES
Sets the ACK character from the set of ASCII characters or any decimal value from 000 to 255. Pad entries of less than three digits
with zeros, as in “005”. To configure this feature, scan the “START/END” bar code above to place the unit in Programming Mode,
then the “Set ACK Character,” followed by the digits from the Alphanumeric table in
your desired character. Exit programming mode by again scanning the “START/END” barcode above.
DEFAULT SETTING FOR THIS FEATURE: 006
Appendix C, Alpha-Numeric Pad representing
Set ACK Character
NAK Character
START / END
PROGRAMMING BARCODES
Sets the NAK character from the set of ASCII characters or any decimal value from 000 to 255. Pad entries of less than three digits
with zeros, as in “005”. To configure this feature, scan the “START/END” bar code above to place the unit in Programming Mode,
then the “Set NAK Character,” followed by the digits from the Alphanumeric table in
your desired character. Exit programming mode by again scanning the “START/END” barcode above.
DEFAULT SETTING FOR THIS FEATURE: 021
Appendix C, Alpha-Numeric Pad representing
Set NAK Character
3-20Magellan
®
1000i
RS-232 Interface Features — cont.
Retry on ACK NAK Timeout
Enables/disables retry after the configurable ACK NAK Timeout Value (set in the following feature) has expired.
START / END
PROGRAMMING BARCODES
Enable Retry on ACK NAK Timeout
DEFAULT
Interface Features
Disable Retry on ACK NAK Timeout
ACK NAK Timeout Value
START / END
PROGRAMMING BARCODES
This item specifies the time the scanner will wait for an ACK character from the host following a label transmission.
000 = Infinite timeout
001 - 075 = Timeout in 200-millisecond increments
To configure this feature, scan the “START/END” bar code above to place the unit in Programming Mode, then the “Set ACK NAK
Timeout Value,” followed by the three digits (zero padded) from the Alphanumeric table in
senting your desired value. Exit programming mode by again scanning the “START/END” barcode above.
DEFAULT SETTING FOR THIS FEATURE: 001 (200 msec)
Appendix C, Alpha-Numeric Pad repre-
Set ACK NAK Timeout Value
Product Reference Guide
3-21
Interface Related Features
RS-232 Interface Features — cont.
ACK NAK Retry Count
START / END
PROGRAMMING BARCODES
This feature sets the number of times for the scanner to retry a label transmission under a retry condition.
000 = No retry
001 - 254 = Retry for the specified number of times
255 = Retry forever
To configure this feature, scan the “START/END” bar code above to place the unit in Programming Mode, then the “Set ACK NAK
Retry Count,” followed by the three digits (zero padded) from the Alphanumeric table in
senting your desired retry count. Exit programming mode by again scanning the “START/END” barcode above
DEFAULT SETTING FOR THIS FEATURE: 003
Appendix C, Alpha-Numeric Pad repre-
Set ACK NAK Timeout Value
3-22Magellan
®
1000i
ACK NAK Error Handling
This item specifies the method the scanner will use to handle errors detected while waiting to
receive the ACK character from the host. Errors include unrecognized host commands and communication errors such as parity or framing errors. Choices are:
00 = Ignore errors detected (recommended setting)
01 = Process error as valid ACK character (risk of lost label data)
02 = Process error as valid NAK character (risk of duplicate label data)
START / END
Interface Features
PROGRAMMING BARCODES
Ignore Errors Detected
DEFAULT
Process error as valid ACK character
Process error as valid NAK character
Product Reference Guide
3-23
Interface Related Features
RS-232 Interface Features — cont.
Transmission Failure Indication
Enables/disables bad-label indication upon transmission failure.
START / END
PROGRAMMING BARCODES
Enable Transmission Error Indication
DEFAULT
Disable Transmission Error Indication
IBM-USB Interface Features
IBM-USB Device usage
The IBM-USB protocol allows for the scanner to be identified as one of two different types of
bar code scanners. Depending on what other scanners you may already have connected to a
IBM-USB POS, you may need to change this setting to enable all devices to communicate.
Options are:
•Table Top Scanner
•Handheld Scanner
START / END
PROGRAMMING BARCODES
Configure as Handheld Scanner
DEFAULT
Configure as Table Top Scanner
3-24Magellan
®
1000i
IBM
Interface Features
IBM Transmit Labels in Code 39 Format
This feature enables/disables scanner's ability to set a symbology identifier for a specified label to
Code 39 before transmitting that label data to an IBM host. This applies to: Code 128, Codabar and Code 93 for IBM USB; Code 128, Codabar and Code 93 for IBM Port 5B; and Codabar and Code 93 for IBM Port 9B.
START / END
PROGRAMMING BARCODES
Disable Convert to Code 39
DEFAULT
Enable Convert to Code 39
Product Reference Guide
3-25
Interface Related Features
Wand Emulation
Supported Symbologies
The Wand Emulation interface will transmit bar code data as a wand device would. This interface will transmit the following bar code symbologies:
•UPC/EAN
•UPC/EAN with addons
•Code 39
•Full ASCII Code 39
•Interleaved 2 of 5
•Codabar
•Code 128
Pharmacode 39 is transmitted as Code 39. All other bar code symbology types read by the scanner will be transmitted as Code 128.
Wand Emulation Bar Code Format
The following format settings are required for the wand emulation interface. These settings have
been pre-configured at the factory for Wand Emulation scanners.
•UPC-A bar codes must include all 12 digits.
•UPC-E bar codes must contain 8 digits, including a system digit, 6 data digits, and the
check digit.
•EAN-13 bar codes must have all 13 digits.
•EAN-8 bar codes must include all 8 digits.
•Code 39, Code 39 Full ASCII, and Pharmacode 39 bar codes must NOT contain start /
stop characters.
•Codabar bar codes must include the start / stop characters, presented in the ABCD format.
•Interleaved 2 of 5 bar codes must have an even number of digits.
3-26Magellan
®
1000i
Wand Emulation — cont.
Bar/Space Polarity
Low/High — Black will be transmitted as a low voltage level (0 to +0.7V) and space as high
level (+2.4 to +5.25V).
High/Low — Black will be transmitted as a high voltage level (+2.4 to +5.25V) and space as
low level (0 to +0.7V).
START / END
Interface Features
PROGRAMMING BARCODES
Bar/Space = Low/High
Bar/Space = High/Low
DEFAULT
Wand Idle State
This feature specifies the level of the wand output signal when idle. TTL logic levels:
High voltage level (+2.4 to +5.25V)
Low voltage level (0 to +0.7V).
START / END
PROGRAMMING BARCODES
Wand Idle State = Low
DEFAULT
Wand Idle State = High
Product Reference Guide
3-27
Interface Related Features
Wand Emulation — cont.
Signal Speed
The speed of the transmission can be set. This selects the width of the minimum narrow bar.
330 microseconds
660 microseconds
START / END
Signal Speed = 660mS
DEFAULT
PROGRAMMING BARCODES
Signal Speed = 330mS
Transmit Trailing Noise
The transmission of noise pulses after the label may be enabled or disabled.
START / END
PROGRAMMING BARCODES
Disable Trailing Noise
Enable Trailing Noise
DEFAULT
3-28Magellan
®
1000i
Wand Emulation — cont.
Transmit Leading Noise
The transmission of noise pulses before the bar code may be enabled or disabled.
START / END
Enable Leading Noise
DEFAULT
Interface Features
PROGRAMMING BARCODES
Disable Leading Noise
Symbology Conversion
Wand Emulation can convert all bar codes to a single symbology. Choices are:
No Conversion
Convert to Code 39
Convert to Code 128
START / END
PROGRAMMING BARCODES
No Symbology Conversion
DEFAULT
Convert to C39
Product Reference Guide
Convert to C128
3-29
Interface Related Features
Keyboard Wedge
and
USB Keyboard
As a keyboard interface, the scanner supports most popular PCs and IBM terminals. The installation of the wedge is a fairly simple process that doesn’t require any changes of software or hardware.
NOTE
Keyboard Layout
The Keyboard Layout option supports many countries. For details about Keyboard Layout,
please refer to your operating system manual.
START / END
All of the options in this section apply to the Keyboard Wedge, however, only some apply to USB Keyboard.
PROGRAMMING BARCODES
Belgium
Denmark
USA
DEFAULT
Britain
France
Germany
3-30Magellan
®
1000i
Keyboard Wedge — cont.
START / END
PROGRAMMING BARCODES
Norway
Interface Features
Italy
Portugal
Spain
Switzerland
Hungary
Sweden
Japan 106 Key
Product Reference Guide
Czech
3-31
Interface Related Features
Keyboard Wedge — cont.
START / END
PROGRAMMING BARCODES
Romania
Slovakia
Croatia
Poland
Caps Lock State
Specifies the format in which the scanner sends character data.
START / END
PROGRAMMING BARCODES
Disable Caps Lock
Caps Lock “ON”
DEFAULT
3-32Magellan
Shift Lock “ON”
®
1000i
Keyboard Wedge — cont.
Power-On Simulation
This feature does not apply to the USB Keyboard
interface.
NOTE
All PCs check the keyboard status during the power-on Selftest. It is recommended that you
enable this function if you are working without a keyboard installation. It simulates keyboard
timing and passes the keyboard status to the PC during power-on.
START / END
PROGRAMMING BARCODES
Interface Features
Disable Power-on Simulation
DEFAULT
Enable Power-on Simulation
Product Reference Guide
3-33
Interface Related Features
Control Characters
Specifies how the scanner transmits ASCII control characters to the host. Choices are:
•Disable Control Characters
•Enable transmission of control characters to host
•Send characters between 00H and 1FH according to a special function-key mapping
table. (This is used to send keys that are not in the normal ASCII set; a unique set is provided for each available scancode set. Reference
pings.)
START / END
Appendix E, Keyboard Function Key Map-
PROGRAMMING BARCODES
Disable Control Characters
DEFAULT
Enable Transmission of Control Characters
Enable Function Key Mapping
3-34Magellan
®
1000i
Interface Features
Keyboard Wedge — cont.
Wedge Quiet Interval
This feature does not apply to the USB Keyboard
interface.
NOTE
Quiet Interval is the amount of time to look for keyboard activity before the scanner breaks the
keyboard connection in order to transmit data to the host.
START / END
PROGRAMMING BARCODES
Selectable from 000 (no interval) to 255 in 10 msec increments. To configure this feature, scan the “START/END” bar code above to
place the unit in Programming Mode, then the Set Wedge Quiet Interval bar code followed by the three digits (zero padded) from
the Alphanumeric table in
scanning the “START/END” barcode above.
Appendix C, Alpha-Numeric Pad representing your desired length. Exit programming mode by again
DEFAULT SETTING FOR THIS FEATURE:
010 (100 msec)
Set Wedge Quiet Interval
Product Reference Guide
3-35
Interface Related Features
Keyboard Wedge — cont.
Intercharacter Delay
This feature does not apply to the USB Keyboard interface.
NOTE
START / END
PROGRAMMING BARCODES
One-half of the delay specified below is inserted between scancodes within each character. If the transmission speed is too high, the
system may not be able to receive all characters. You may need to adjust the delay to make the system work properly. Selectable
from 000 to 255 in 10msec increments.
To configure this feature, scan the “START/END” bar code above to place the unit in Programming Mode, then the “Set Intercharacter Delay,” followed by the three digits (zero padded) from the Alphanumeric table in
ing your desired length. Exit programming mode by again scanning the “START/END” barcode above/
DEFAULT SETTING FOR THIS FEATURE:
000 (No Delay)
Appendix C, Alpha-Numeric Pad represent-
Set Intercharacter Delay
3-36Magellan
®
1000i
Data Editing Overview
It is not recommended to use these features with IBM
or Wand Emulation interfaces.
CAUTION
When a bar code is scanned, additional information can be sent to the host computer along
with the bar code data. This combination of bar code data and supplementary user-defined
data is called a “message string.” The features in this chapter can be used to build specific
user-defined data into a message string.
There are several types of selectable data characters that can be sent before and after scanned
data. You can specify if they should be sent with all symbologies, or only with specific symbolo-
Figure 4-1 shows the available elements you can add to a message string:
gies.
Chapter 4
Data Editing
Figure 4-1. Breakdown of a Message String
Label ID Transmission:
Enable this option to
transmit the Label ID you
configure for the scanned
PrefixSuffixAIM IDLabel IDLabel IDBar Code Data
Please Keep In Mind...
•Modifying a message string is not a mandatory requirement. Data editing is sophisticated
feature allowing highly customizable output for advanced users. Factory default settings
for data editing is typically set to NONE.
•A prefix or suffix may be applied (reference the
across all symbologies (set via the Global features in this chapter).
symbology.
OR...
AIM ID: This function is used to identify and display the
common label identifier for its symbology. When enabled,
this ID code will be transmitted before the scanned bar
code data.
00 - 20 Characters (ASCII)
Symbologies chapter for these settings)
•You can add any character from the ASCII Chart (from 00-FF) on the inside back cover of
this manual as a prefix, suffix or Label ID.
Product Reference Guide
4-1
Data Editing
•Enter prefixes and suffixes in the order in which you want them to appear on the output.
Global Prefix/Suffix
Up to 20 ASCII characters may be added as a prefix (in a position before the bar code data) and/
or as a suffix (in a position following the bar code data) as indicated in
Figure 4-2. Prefix and Suffix Positions
PrefixSuffixAIM IDLabel IDLabel IDBar Code Data
Example: Setting a Prefix
In this example, we’ll set a prefix for all symbologies.
Figure 4-2.
OR...
00 - 20 Characters (ASCII)
AND
OR
1. Determine which ASCII character(s) are to be added to scanned bar code data. In this
example, we’ll add a dollar sign (‘$’) as a prefix.
2. Scan the START bar code.
3. Scan the SET PREFIX bar code.
4. Reference the
ASCII Chart on the inside back cover of this manual, to find the hex value
assigned to the desired character. The corresponding hex number for the ‘$’ character is
24. To enter this selection code, scan the ‘2’ and ‘4’ bar codes from
Numeric Pad.
Appendix C, Alpha-
5. Scan the END bar code to exit Programming Mode.
If less than the expected string of 20 characters are
selected, scan the END bar code twice to accept the
selections and exit Programming Mode.
NOTE
6. The resulting message string would appear as follows:
Scanned bar code data:12345
Resulting message string output: $12345
4-2Magellan
®
1000i
Global Prefix/Suffix
Global Prefix/Suffix — cont.
START / END
PROGRAMMING BARCODES
Sets up to 20 characters each from the set of ASCII characters or any hex value from 0 to FF. To configure this feature, scan the
“START/END” bar code above to place the unit in Programming Mode, then the “Set Prefix” or “Set Suffix,” followed by the digits from
the Alphanumeric table in
"Example: Setting a Prefix", for more information. Exit programming mode by scanning the “START/END” barcode again (scan
“START/END” twice if less than 20 characters have been selected).
Appendix C, Alpha-Numeric Pad representing your desired character(s). Reference the section,
DEFAULT SETTING PREFIX: 00 (None)
DEFAULT SETTING SUFFIX: 0D (CR)
Set Prefix
Set Suffix
Product Reference Guide
4-3
Data Editing
AIM ID
AIM (Automatic Identification Manufacturers) label identifiers are assigned from a globally
standardized list — as opposed to custom label ID characters you select yourself — and can be
included with scanned bar code data. AIM label identifiers consist of three characters as follows:
•A close brace character (ASCII ‘]’), followed by...
•A code character (see the table below), followed by...
•A modifier character (the modifier character is symbol dependent)
SYMBOLOGYCHARSYMBOLOGYCHAR
UPC/EANECode 128/EAN 128C
Code 39AMSI/PlesseyM
CodabarF
RSS (RSS-14, RSS
Expanded)
Interleaved 2 of 5IStandard 2 of 5S
Code 93
a. ISBN (X with a 0 modifier character)
GISBN
Figure 4-3. AIM ID
PrefixSuffixLabel IDLabel IDBar Code DataAIM ID
START / END
e
a
X
Enable AIM ID
4-4Magellan
PROGRAMMING BARCODES
Disable AIM ID
DEFAULT
®
1000i
Label ID
Label ID
A Label ID is a customizable code of up to two ASCII characters (00-FF), used to identify a bar
code (symbology) type. See
Appendix D, Default Settings, for a listing for common symbologies. It
can be appended previous to or following the transmitted bar code data depending upon how
this option is enabled. This feature provides options for configuring custom Label IDs individually per symbology. If you wish to program the scanner to always include an industry standard
label identifier for ALL symbology types, see the previous feature,
AIM ID.
To configure a Label ID:
1. Scan the START bar code.
2. Select Label ID position as either BEFORE or AFTER by scanning the appropriate bar
code.
3. Scan a bar code to select the symbology for which you wish to configure a custom Label
ID.
4. Determine the desired character(s) (you may choose either one or two) which will represent the Label ID for the selected symbology. Next, turn to the
ASCII Chart on the inside
back cover of this manual and find the equivalent hex digits associated with your choice of
Label ID. For example, if you wish to select an equal sign (=) as a Label ID, the chart indicates its associated hex characters as 3D.
5. Turn to
Appendix C, Alpha-Numeric Pad and scan the bar codes representing the hex charac-
ters determined in the previous step. For the example given, the characters ‘3’ and ‘D’
would be scanned.
6. Scan the END bar code to exit programming mode.
Figure 4-4. Label ID Position Options
PrefixSuffixLabel IDLabel IDBar Code DataAim ID
OR
Product Reference Guide
4-5
Data Editing
Label ID — cont.
START / END
Label ID Position: Before Bar Code Data
DEFAULT
PROGRAMMING BARCODES
Label ID Transmission: Disable
Label ID Position: After Bar Code Data
Set UPC-A Label ID Character(s)
DEFAULT SETTING FOR THIS FEATURE: A (41 hex)
Set UPC-A w/P5 Addon Label ID Character(s)
DEFAULT SETTING FOR THIS FEATURE: A (41 hex)
Set UPC-E Label ID Character(s)
DEFAULT SETTING FOR THIS FEATURE: A (41 hex)
Set UPC-A w/P2 Addon Label ID Character(s)
DEFAULT SETTING FOR THIS FEATURE: A (41 hex)
Set UPC-A w/C128 Addon Label ID Character(s)
DEFAULT SETTING FOR THIS FEATURE: E (45 hex)
4-6Magellan
®
1000i
Label ID — cont.
START / END
DEFAULT SETTING FOR THIS FEATURE: E (45 hex)
Set UPC-E w/P5 Addon Label ID Character(s)
DEFAULT SETTING FOR THIS FEATURE: E (45 hex)
Label ID
PROGRAMMING BARCODES
Set UPC-E w/P2 Addon Label ID Character(s)
DEFAULT SETTING FOR THIS FEATURE: E (45 hex)
Set UPC-E w/C128 Addon Label ID Character(s)
Set EAN-8 Label ID Character(s)
DEFAULT SETTING FOR THIS FEATURE: FF (4646 hex)
Set EAN-8 w/P5 Addon Label ID Character(s)
DEFAULT SETTING FOR THIS FEATURE: FF (4646 hex)
Set EAN-13 Label ID Character(s)
DEFAULT SETTING FOR THIS FEATURE: FF (4646 hex)
Set EAN-8 w/P2 Addon Label ID Character(s)
DEFAULT SETTING FOR THIS FEATURE: FF (4646 hex)
Set EAN-8 w/C128 Addon Label ID Character(s)
DEFAULT SETTING FOR THIS FEATURE: F (46 hex)
Product Reference Guide
4-7
Data Editing
Label ID — cont.
START / END
DEFAULT SETTING FOR THIS FEATURE: F (46 hex)
Set EAN-13 w/P5 Addon Label ID Character(s)
DEFAULT SETTING FOR THIS FEATURE: F (46 hex)
PROGRAMMING BARCODES
Set EAN-13 w/P2 Addon Label ID Character(s)
DEFAULT SETTING FOR THIS FEATURE: F (46 hex)
Set EAN-13 w/C128 Addon Label ID Character(s)
Set ISBN Label ID Character(s)
DEFAULT SETTING FOR THIS FEATURE: IA (4941 hex)
Set GTIN Label ID Character(s)
DEFAULT SETTING FOR THIS FEATURE: G2 (4732 hex)
Set GTIN w/P5 addon Label ID Character(s)
DEFAULT SETTING FOR THIS FEATURE: I (49 hex)
Set IATA Label ID Character(s)
DEFAULT SETTING FOR THIS FEATURE: G (47 hex)
Set GTIN w/P2 addon Label ID Character(s)
DEFAULT SETTING FOR THIS FEATURE: G5 (4735 hex)
4-8Magellan
®
1000i
Label ID — cont.
START / END
PROGRAMMING BARCODES
DEFAULT SETTING FOR THIS FEATURE: G8 (4738 hex)
Set RSS-14 Label ID Character(s)
Label ID
Set GTIN w/C128 addon Label ID Character(s)
DEFAULT SETTING FOR THIS FEATURE: R4 (5234 hex)
Set RSS Expanded Label ID Character(s)
DEFAULT SETTING FOR THIS FEATURE: RX (5258 hex)
Set Code 39 Label ID Character(s)
DEFAULT SETTING FOR THIS FEATURE: A (41 hex)
Set Code 128 Label ID Character(s)
DEFAULT SETTING FOR THIS FEATURE: i (69 hex)
DEFAULT SETTING FOR THIS FEATURE: * (2A hex)
Set Pharmacode 39 Label ID Character(s)
DEFAULT SETTING FOR THIS FEATURE: # (23 hex)
Set I 2 of 5 Label ID Character(s)
Product Reference Guide
4-9
Data Editing
Label ID — cont.
START / END
DEFAULT SETTING FOR THIS FEATURE: % (25 hex)
Set Code 93 Label ID Character(s)
DEFAULT SETTING FOR THIS FEATURE: @ (40 hex)
PROGRAMMING BARCODES
Set Codabar Label ID Character(s)
DEFAULT SETTING FOR THIS FEATURE: & (26 hex)
Set Code 11 Label ID Character(s)
Set MSI/Plessey Label ID Character(s)
DEFAULT SETTING FOR THIS FEATURE: s (73 hex)
Set EAN UCC Composite Label ID Character(s)
DEFAULT SETTING FOR THIS FEATURE: @ (40 hex)
Set Std 2 of 5 Label ID Character(s)
DEFAULT SETTING FOR THIS FEATURE: 0
4-10Magellan
®
1000i
Case Conversion
This feature can convert scanned bar code data to either all lower case (a through z) or all upper
case (A through Z) characters.
NOTE
START / END
Case Conversion
Case conversion affects ONLY scanned bar code data,
and does not affect Label ID, Prefix, Suffix, or other
appended data.
PROGRAMMING BARCODES
Disable
DEFAULT
Convert to Upper Case
Convert to Lower Case
Product Reference Guide
4-11
Data Editing
Character Conversion
Character conversion is an eight byte configuration item. The eight bytes are 4 character pairs
represented in hexadecimal ASCII values. The first character in the pair is the character that
will be converted. The second character in the pair is the character to convert to. If the character to convert in a pair is FF, then no conversion is done.
For example, if you have the character conversion configuration item set to the following:
41423132FFFFFFFF
The first pair is 4142 or AB (41 hex is an ASCII capital A, 42 hex is an ASCII capital B) and
the second pair is 3132 or 12 (31 hex is an ASCII 1, 32 is an ASCII 2). The other two pairs
are FFFF and FFFF.
With the label, AG15TA81, it would look as follows after the character conversion:
BG25TB82.
The A characters were converted to the B character and the 1 characters were converted to the
numeral 2 character. Nothing is done with the last two character pairs, since they are all FF.
To set Character Conversion:
1. Scan the START/END bar code.
2. Scan the Character Conversion bar code.
3. Determine the desired string. Up to sixteen positions can be determined as in the above
example. Next, turn to the
the equivalent hex digits needed to fulfill the string.
4. Turn to Appendix C, Alpha-Numeric Pad and scan the bar codes representing the hex characters determined in the previous step.
5. Scan the START/END bar code to exit Programming Mode.
If less than the expected string of 16 characters are
selected, scan the START/END bar code twice to accept
the selections and exit Programming Mode.
NOTE
START / END
PROGRAMMING BARCODES
DEFAULT SETTING FOR THIS FEATURE:
FFFFFFFFFFFFFFFF hex (no conversion)
ASCII Chart on the inside back cover of this manual and find
Character Conversion
4-12Magellan
®
1000i
Chapter 5
Symbologies
The scanner supports the following symbologies (bar code types). Options for each symbology
are included in this chapter.
·UPC-A·Pharmacode 39
·UPC-E·Code 128
·EAN-13·Interleaved 2 of 5
·EAN-8·Codabar
·RSS-14·Code 93
·RSS Expanded·MSI/Plessey
·Code 39·Standard 2 of 5
Factory Defaults —
this section. Reference
UPC-A
Disable/Enable UPC-A
When disabled, the scanner will not read UPC-A bar codes.
START / END
Enable UPC-A
DEFAULT
for the standard RS-232 interface are indicated in bold text throughout
Appendix D, Default Settings for default exceptions for your interface.
PROGRAMMING BARCODES
Disable UPC-A
Product Reference Guide
5-1
Symbologies
UPC-A — continued
Check Digit Transmission
Enable this option to transmit the check digit along with UPC-A bar code data.
START / END
PROGRAMMING BARCODES
Send Check Digit
DEFAULT
Don’t Send Check Digit
Expand UPC-A to EAN-13
Expands UPC-A data to the EAN-13 data format. Selecting this feature also changes the symbology ID to match those required for EAN-13.
START / END
PROGRAMMING BARCODES
Expand to EAN-13
Don’t Expand to EAN-13
DEFAULT
5-2Magellan
®
1000i
UPC-A — continued
Number System Transmission
This feature enables/disables transmission of UPC-A System Number.
START / END
PROGRAMMING BARCODES
Enable Number System Transmission
DEFAULT
UPC-A
Disable Number System Transmission
UPC-A Minimum Reads
This feature specifies the minimum number of consecutive times a UPC-A label must be
decoded before it is accepted as good read.
START / END
Minimum = 2 Reads
PROGRAMMING BARCODES
Minimum = 1 Read
DEFAULT
Minimum = 3 Reads
Minimum = 4 Reads
Product Reference Guide
5-3
Symbologies
UPC-A — continued
UPC-A In-store Minimum Reads
This feature specifies the minimum number of consecutive times an in-store printed label must
be decoded before it is accepted as good read.
START / END
PROGRAMMING BARCODES
Minimum = 2 Reads
Minimum = 1 Read
DEFAULT
Minimum = 4 Reads
Minimum = 3 Reads
5-4Magellan
®
1000i
UPC-E
The following options apply to the UPC-E symbology.
Disable/Enable UPC-E
When disabled, the scanner will not read UPC-E bar codes.
START / END
Enable UPC-E
DEFAULT
UPC-E
PROGRAMMING BARCODES
Disable UPC-E
Check Digit Transmission
Enable this option to transmit the check digit along with UPC-E bar code data.
START / END
PROGRAMMING BARCODES
Send Check Digit
DEFAULT
Don’t Send Check Digit
Product Reference Guide
5-5
Symbologies
UPC-E — continued
Number System Digit
The Number System Digit (NSD) which is always a zero (0) in the leading position can be
optionally included (or not) with scanned bar code data.
START / END
Include Number System Digit
PROGRAMMING BARCODES
Exclude Number System Digit
DEFAULT
Expand to UPC-E to UPC-A
Enables/disables expansion of UPC-E labels to UPC-A. Selecting this feature also changes the
symbology ID to match those required for UPC-A.
START / END
PROGRAMMING BARCODES
Expand UPC-E to UPC-A
Don’t Expand UPC-E to UPC-A
DEFAULT
5-6Magellan
®
1000i
UPC-E — continued
Expand UPC-E to EAN13
Enables/disables expansion of UPC-E labels to EAN-13. Selecting this feature also changes the
symbology ID to match those required for EAN-13.
START / END
Expand UPC-E to EAN-13
UPC-E
PROGRAMMING BARCODES
Don’t Expand UPC-E to EAN-13
DEFAULT
Minimum Reads
This feature specifies the minimum number of consecutive times a UPC-E label must be
decoded before it is accepted as good read.
START / END
Minimum = 2 Reads
DEFAULT
PROGRAMMING BARCODES
Minimum = 1 Read
Minimum = 3 Reads
Minimum = 4 Reads
Product Reference Guide
5-7
Symbologies
GTIN
The following options apply to the GTIN label data format.
Expand UPC/EAN to GTIN
When this feature is enabled, the scanner will translate UPC/EAN labels to the 14 digit GTIN
format.
START / END
PROGRAMMING BARCODES
Expand to GTIN
Don’t Expand to GTIN
DEFAULT
5-8Magellan
®
1000i
EAN-13
The following options apply to the EAN-13 symbology.
Disable/Enable EAN-13
When disabled, the scanner will not read EAN-13 bar codes.
START / END
Enable EAN-13
DEFAULT
EAN-13
PROGRAMMING BARCODES
Disable EAN-13
Check Digit Transmission
Enable this option to transmit the check digit along with EAN-13 bar code data.
START / END
PROGRAMMING BARCODES
Send Check Digit
DEFAULT
Don’t Send Check Digit
Product Reference Guide
5-9
Symbologies
EAN-13 — continued
EAN-13 Flag 1 Character
Enables/disables transmission of an EAN/JAN13 Flag1 character.
START / END
Transmit EAN-13 Flag 1 Char
DEFAULT
PROGRAMMING BARCODES
Don’t Transmit EAN-13 Flag 1 Char
ISBN
When enabled, this feature truncates the leading three digits from labels that contain ISBN
(International Standard Book Number) and appends an ISBN check character to the end of the
label. These codes are used for books and magazines. Labels with ISBN codes start with "978".
Example:
Bar code data:“9789572222720”
Output:“9572222724”
START / END
PROGRAMMING BARCODES
Disable ISBN
DEFAULT
Enable ISBN
5-10Magellan
®
1000i
EAN-13 — continued
Minimum Reads
This feature specifies the minimum number of consecutive times an EAN-13 label must be
decoded before it is accepted as good read.
START / END
Minimum = 2 Reads
EAN-13
PROGRAMMING BARCODES
Minimum = 1 Read
DEFAULT
Minimum = 4 Reads
Minimum = 3 Reads
Product Reference Guide
5-11
Symbologies
EAN-8
The following options apply to the EAN-8 symbology.
Disable/Enable EAN-8
When disabled, the scanner will not read EAN-8 bar codes.
START / END
Enable EAN-8
DEFAULT
PROGRAMMING BARCODES
Disable EAN-8
Check Digit Transmission
Enable this option to transmit the check Digit along with EAN-8 bar code data.
START / END
PROGRAMMING BARCODES
Send Check Digit
DEFAULT
Don’t Send Check Digit
5-12Magellan
®
1000i
EAN-8 — continued
EAN-8
Expand EAN-8 to EAN-13 —
this feature also changes the symbology ID to match those required for EAN-13.
START / END
Expand to EAN-13
Minimum Reads
This feature specifies the minimum number of consecutive times an EAN-8 label must be
decoded before it is accepted as good read.
Expands EAN-8 data to the EAN-13 data format. Selecting
PROGRAMMING BARCODES
Don’t Expand to EAN-13
DEFAULT
START / END
Minimum = 2 Reads
Minimum = 4 Reads
PROGRAMMING BARCODES
Minimum = 1 Read
DEFAULT
Minimum = 3 Reads
Product Reference Guide
5-13
Symbologies
Enable EAN Two-Label
Enables/disables the ability of the scanner to decode EAN two-label pairs.
START / END
PROGRAMMING BARCODES
Enable EAN Two-Label
Disable EAN Two-Label
5-14Magellan
®
1000i
Add-ons
Add-ons
Add-ons (or supplemental characters) are commonly added to the end of UPC/EAN bar codes.
The scanner will read the add-ons if they are enabled and in the field of view. Three add-on
types are supported: 2-digit, 5-digit and Code 128 add-ons. Supported options are:
None —
still read the main portion of the bar code.
2 Digits —
5 Digits —
Code 128 Add-on —
EAN label.
This option directs the scanner to ignore add-on portion of a UPC/EAN bar code but
The scanner will optionally read 2-digit add-ons with the UPC/EAN label.
The scanner will optionally read 5-digit add-ons with the UPC/EAN label.
The scanner will optionally read Code 128 add-ons with the UPC/
Contact Customer Support for
advanced programming of optional
NOTE
and conditional add-ons.
Product Reference Guide
5-15
Symbologies
Add-ons — continued
START / END
Enable Optional 2-Digit Add-ons
PROGRAMMING BARCODES
Disable Optional 2-Digit Add-ons
DEFAULT
Disable Optional 5-Digit Add-ons
DEFAULT
Enable Optional 5-Digit Add-ons
Enable Optional Code 128 Add-ons
Disable Optional Code 128 Add-ons
DEFAULT
5-16Magellan
®
1000i
RSS-14
The following options apply to the RSS-14 symbology.
Disable/Enable RSS-14
When this feature is disabled, the scanner will not read RSS-14 bar codes.
START / END
Enable RSS-14
RSS-14
PROGRAMMING BARCODES
Disable RSS-14
DEFAULT
UCC/EAN 128 Emulation
When enabled, RSS-14 bar codes will be translated to the UCC/EAN 128 label data format.
START / END
Enable UCC/EAN 128 Emulation
PROGRAMMING BARCODES
Disable UCC/EAN 128 Emulation
DEFAULT
Product Reference Guide
5-17
Symbologies
RSS-14 — continued
Minimum Reads
This feature specifies the minimum number of consecutive times an RSS-14 label must be
decoded before it is accepted as good read.
START / END
Minimum = 2 Reads
PROGRAMMING BARCODES
Minimum = 1 Read
DEFAULT
Minimum = 4 Reads
Minimum = 3 Reads
5-18Magellan
®
1000i
RSS Expanded
The following options apply to the RSS Expanded symbology.
Disable/Enable RSS Expanded
When this feature is disabled, the scanner will not read RSS Expanded bar codes.
START / END
PROGRAMMING BARCODES
Enable RSS Expanded
RSS Expanded
Disable RSS Expanded
DEFAULT
UCC/EAN 128 Emulation
When enabled, RSS Expanded bar codes will be translated to the UCC/EAN 128 label data format.
START / END
Enable UCC/EAN 128 Emulation
PROGRAMMING BARCODES
Disable UCC/EAN 128 Emulation
DEFAULT
Product Reference Guide
5-19
Symbologies
RSS Expanded — continued
Length Control
Fixed Length Decoding —
When fixed length decoding is enabled, the scanner will decode a
bar code if the label length matches one of the configurable fixed lengths.
Variable Length Decoding —
When variable length decoding is enabled, the scanner will
decode a bar code if the label length falls in the range of the configurable minimum and maximum length.
Configuring Fixed Length Decoding:
1. Scan the START/END bar code.
2. Scan the Fixed Length Decoding bar code.
3. Scan the START/END bar code.
4. Set Length 1 to the first fixed length by following the
Programming Instructions
below.
RSS Expanded Length 1, Length 2
5. Set Length 2 to the second fixed length (or to ‘000’ if there is only one fixed length) by
following the RSS Expanded Length 1, Length 2 Programming Instructions below.
Configuring Variable Length Decoding:
1. Scan the START/END bar code.
2. Scan the Variable Length Decoding bar code.
3. Scan the START/END bar code.
4. Set Length 1 to the first variable length by following the
Programming Instructions
below.
5. Set Length 2 to the second variable length by following the
2. Scan either the Set Length 1 or Set Length 2 bar code.
3. Turn to
Appendix C, Alpha-Numeric Pad and scan the three digits (zero padded) represent-
ing the length in decimal notation.
For RSS Expanded bar codes, only the data
characters are included in the length calculations.
NOTE
4. Scan the START/END bar code.
START / END
PROGRAMMING BARCODES
DEFAULT SETTING FOR THIS FEATURE: 008
Set Length 2
Set Length 1
DEFAULT SETTING FOR THIS FEATURE: 014
Product Reference Guide
5-21
Symbologies
RSS Expanded — continued
Minimum Reads
This feature specifies the minimum number of consecutive times an RSS Expanded label must
be decoded before it is accepted as good read.
START / END
PROGRAMMING BARCODES
Minimum = 2 Reads
Minimum = 1 Read
DEFAULT
Minimum = 4 Reads
Minimum = 3 Reads
5-22Magellan
®
1000i
Code 39
The following options apply to the Code 39 symbology.
Disable/Enable Code 39
When this feature is disabled, the scanner will not read Code 39 bar codes.
START / END
Enable Code 39
DEFAULT
Code 39
PROGRAMMING BARCODES
Disable Code 39
Check Character Calculation
When enabled, the scanner will calculate the check character of the labels. Turn this option on
only when a checksum is present in the Code 39 labels.
START / END
PROGRAMMING BARCODES
Enable Check Char Calculation
Disable Check Char Calculation
DEFAULT
Product Reference Guide
5-23
Symbologies
Check Character Transmit
Enable this option to transmit the check character with scanned bar code data.
START / END
PROGRAMMING BARCODES
Enable Check Char Transmission
DEFAULT
Start/Stop Characters
Enables/disables transmission of Code39 start and stop characters.
Disable Check Char Transmission
START / END
Transmit Start/Stop Characters
PROGRAMMING BARCODES
Don’t Transmit Start/Stop Characters
DEFAULT
5-24Magellan
®
1000i
Code 39 Full ASCII
Enables/disables the translation of Code 39 characters to Code 39 full-ASCII characters.
START / END
Enable Code 39 Full ASCII
Code 39
PROGRAMMING BARCODES
Disable Code 39 Full ASCII
DEFAULT
Product Reference Guide
5-25
Symbologies
Code 39 — continued
Length Control
Fixed Length Decoding —
When fixed length decoding is enabled, the scanner will decode a
bar code if the label length matches one of the configurable fixed lengths.
Variable Length Decoding —
When variable length decoding is enabled, the scanner will
decode a bar code if the label length falls in the range of the configurable minimum and maximum length.
Configuring Fixed Length Decoding:
1. Scan the START/END bar code.
2. Scan the Fixed Length Decoding bar code.
3. Scan the START/END bar code.
4. Set Length 1 to the first fixed length by following the
ming Instructions
below.
Code 39 Length 1, Length 2 Program-
5. Set Length 2 to the second fixed length (or to ‘000’ if there is only one fixed length) by
following the Code 39 Length 1, Length 2 Programming Instructions below.
Configuring Variable Length Decoding:
1. Scan the START/END bar code.
2. Scan the Variable Length Decoding bar code.
3. Scan the START/END bar code.
4. Set Length 1 to the first variable length by following the
gramming Instructions
below.
5. Set Length 2 to the second variable length by following the
gramming Instructions
START / END
Fixed Length Decoding
below.
PROGRAMMING BARCODES
Variable Length Decoding
Code 39 Length 1, Length 2 Pro-
Code 39 Length 1, Length 2 Pro-
DEFAULT
5-26Magellan
®
1000i