DATALOGIC Ethernet Multi Cradle User Manual

Datalogic J Series™ Ethernet Multi Cradle
The Datalogic J Series™ Ethernet Multi Cradle provides power for charging up to four mobile computers simultaneously and also connects up to four mobile computers to an Ethernet network.
C
A
D
Figure 1 – Datalogic J Series™ Ethernet Multi Cradle General View
E
822000752 (Rev. B)
F
B
The Ethernet cradle drivers are pre-installed on the Datalogic J Series™ and initiate automatically when the Datalogic J Series™ is placed in a properly connected Four Slot Ethernet cradle.
When the mobile computer is inserted into the Four Slot Ethernet cradle, the LAN icon indicates that the mobile computer is connected to a network.
Ethernet communication requires Datalogic J Series™ PDA SW version 5.41 or later. Verify the software version by tapping on Software – Version in the Datalogic default home page. Otherwise, search for
NOTE
The green Speed LED lights to indicate that the transfer rate is 100 Mbps. When it is not lit it indicates that the transfer rate is 10Mbps.
NOTE
The yellow Link LED blinks to indicate activity, or stays lit to indicate that a link is established. When it is not lit it indicates that there is no link.
The Speed LED and the Link LED integrated in Ethernet Port 1 and 2 function in the same way.
The Charging Status LED on the mobile computer shows the status of the battery charging. The maximum time required to recharge a completely run-down battery pack is about 2.5 hours for Li-Ion batteries. See Datalogic J Series™ User’s Manual par. 3.5.1 for Charging Status LED indications.
the file version.htm under the Windows folder.
The maximum bandwidth capacity for each Mobile Computer is 12Mbps.
Correct Mobile Computer Insertion / Removal
Insert the mobile computer into a slot to begin charging and start communication.
For correct insertion onto the cradle, insert the mobile computer from the top of the cradle and push it down firmly.
Figure 2 - Mobile Computer Insertion
To remove the mobile computer from the Datalogic J Series™ Ethernet Multi Cradle, simply pull it upwards while holding the cradle firmly down.
Power Supply
Each Ethernet Multi Cradle requires a power supply to be connected to the cradle. We recommend the DL FPS18 power supply.
Figure 3 - Power Supply Polarity
VEXT
GND
CONNECTIONS
Connections should always be made with power OFF!
CAUTION
Ethernet Connection
Connect the Ethernet cradle (Ethernet port 1) to an Ethernet hub or a port on the host device. Connect the Ethernet cradle (power port) to power supply.
A
D
B
Figure 4 - Ethernet Connection
94ACC1150 Power cord EU 3-pin C) UTP CAT 5E cable (recommended use) D) Ethernet hub
C
Daisychaining Ethernet Connection
To connect several cradles to an Ethernet network, Ethernet cradles may be daisychained. It is recommended not to connect more than 4 cradles in order to maintain the optimal baud rate. The Speed LED and the Link LED on the Ethernet Port 2 function in the same way as the Speed LED and the Link LED on the front of the cradle.
To daisychain cradles:
1. Connect the first Ethernet cradle to power and to the Ethernet Switch as shown on Figure 4.
2. Connect power to the second Ethernet cradle.
3. Connect the daisychain Ethernet cable (either straight or twisted cable can be used) between Ethernet Port 2 of the first cradle, and Ethernet Port 1 of the second cradle.
4. Connect additional cradles as shown in Figure 4.
D
TECHNICAL FEATURES
Electrical Features
Power supply * from 12 to 14 VDC ± 5% Consumption Max 4.2 A Indicators Ethernet Link LED (yellow)
Ethernet Speed LED (green)
Charge time (when PDA is off) max 2.5 hours (Li ION batteries)
Communication Features
Interface Ethernet 10/100 Base T
Environmental Features
Working temperature 0° to +50°C / 32° to 140°F ** Storage temperature -20° to +70°C / -4° to 158°F Humidity 90% non condensing Degree of protection IP20
Mechanical Features
Dimensions 480 x 110 x 190 mm
18.89 x 4.33 x 7.48 in
Weight about 2750 g / 97 oz
* Recommended DL power supply: FPS18. ** Batteries must be charged at a temperature ranging from 0° to 45 °C
(+32° to 113°F).
E
B
A
Figure 5 - Daisychaining Ethernet Connection
94ACC1150 Power cord EU 3-pin
E) UTP CAT 5E cable (recommended use).
C