Datalogic 0016 Users Manual

Kyman-NET™
USER'S MANUAL
DATALOGIC S.p.A. Via Candini 2 40012 - Lippo di Calderara di Reno Bologna - Italy
Kyman-NET™ - User's Manual
ALL RIGHTS RESERVED Datalogic reserves the right to make modifications and improvements without prior notification.
Datalogic shall not be liable for technical or editorial errors or omissions contained herein, nor for incidental or consequential damages resulting from the use of this material.
Product names mentioned herein are for identification purposes only and may be trademarks and or registered trademarks of their respective companies.
© Datalogic S.p.A. 2004-2006
CONTENTS
DATALOGIC END USER LICENSE AGREEMENT..................................... v
REFERENCES ........................................................................................... vii
Conventions.................................................................................................vii
Reference Documentation ...........................................................................vii
Services and Support...................................................................................vii
SAFETY REGULATIONS.......................................................................... viii
General Safety Rules.................................................................................. viii
Laser Safety..................................................................................................ix
Radio Compliance....................................................................................... xiii
Information for the User ..............................................................................xiii
FCC COmpliance........................................................................................xiv
WEEE Compliance .....................................................................................xiv
GENERAL VIEW ........................................................................................ xv
1 INTRODUCTION .......................................................................................... 1
1.1 Kyman-NET™ Description............................................................................ 1
1.2 Available Models........................................................................................... 2
1.3 Package Contents......................................................................................... 2
1.3.1 Using the Belt Clip ........................................................................................ 3
1.4 Accessories................................................................................................... 5
2 CONNECTIONS ........................................................................................... 6
2.1 Connection to the Host Computer................................................................. 6
2.1.1 RS232/USB Direct Connection ..................................................................... 6
2.1.2 WLAN Connection ........................................................................................ 7
2.1.3 WPAN Connections ......................................................................................8
2.1.4 WWAN Connections .....................................................................................9
2.2 Connection Cables...................................................................................... 12
3 USE AND FUNCTIONING.......................................................................... 14
3.1 Startup ........................................................................................................14
3.2 Using the Stylus.......................................................................................... 15
3.3 Data Capture............................................................................................... 16
3.3.1 Laser Data Capture..................................................................................... 16
3.3.2 Imager Data Capture .................................................................................. 17
3.3.3 RFID Data Capture ..................................................................................... 18
3.4 Description of the Keys ............................................................................... 19
3.4.1 Alphanumeric Keyboard (53-key Model)..................................................... 19
3.4.2 Numeric Keyboard (36-key Model) ............................................................. 22
iii
3.5 Status Indicators ......................................................................................... 25
3.5.1 LED Status.................................................................................................. 25
3.5.2 Status Bar ................................................................................................... 26
3.6 Data Capture Configuration ........................................................................ 27
3.6.1 Configure .................................................................................................... 27
3.6.2 Capture ....................................................................................................... 31
3.7 Control Panel .............................................................................................. 32
3.7.1 Buttons........................................................................................................ 33
3.7.2 Registry....................................................................................................... 33
3.7.3 Files Admin ................................................................................................. 34
3.7.4 Wireless Communications........................................................................... 36
3.7.5 Volume Settings.......................................................................................... 37
3.8 Windows Connections ................................................................................ 40
3.8.1 Microsoft® ActiveSync® ............................................................................. 40
3.8.2 Bluetooth® Manager Device Setup............................................................. 42
3.9 Backup Directory File Management ............................................................ 45
4 MAINTENANCE ......................................................................................... 46
4.1 Charging the Battery Pack .......................................................................... 46
4.2 Replacing the Battery Pack......................................................................... 47
4.3 Compact Flash and Secure Storage Cards................................................. 49
4.4 Cleaning the Mobile Computer.................................................................... 49
5 TECHNICAL FEATURES........................................................................... 50
5.1 Technical Data ............................................................................................ 50
5.2 Reading Diagrams ......................................................................................54
6 TEST CODES............................................................................................. 56
GLOSSARY................................................................................................ 59
INDEX......................................................................................................... 61
iv
DATALOGIC END USER LICENSE AGREEMENT
BY DOWNLOADING OR INSTALLING THE SOFTWARE, OR BY USING DATALOGIC EQUIPMENT THAT INCLUDES THIS SOFTWARE, YOU ARE CONSENTING TO BE BOUND BY THIS AGREEMENT. IF YOU DO NOT AGREE TO ALL OF THE TERMS OF THIS AGREEMENT, THEN DO NOT DOWNLOAD, INSTALL, USE THE SOFTWARE NOR DATALOGIC EQUIPMENT.
The following terms and conditions govern your use of the Software except to the extent that a particular program (a) is the subject of a separate written agreement with Datalogic or (b) includes a separate “click-on” license agreement as part of the installation and/or download process. Should a conflict arise between the provisions of the foregoing documents, the order of precedence shall be (1) the written agreement, (2) the click-on agreement, and (3) this agreement (“Agreement”).
1. License. Subject to the terms and conditions of and except as otherwise provided in this Agreement, Datalogic S.p.A. (“Datalogic”) and its suppliers grant to Customer (“Customer”) a nonexclusive and nontransferable license to use the specific program modules, feature set(s) or feature(s) in object code form only as well as associated media, printed materials and “online” or electronic documentation (the “Software”) for which Customer has paid, if required, the license fees. The Software is licensed not sold. The license shall be subject to each of the following limitations:
Unless otherwise expressly provided in the documentation, Customer shall use the Software solely as embedded in, for execution on, or (where the applicable documentation permits installation on non-Datalogic equipment) for communication with Datalogic equipment owned or leased by Customer;
Customer’s use of the Software shall be limited to use on a single hardware chassis, on a single central processing unit, as applicable, or use on such greater number of chassis or central processing units as Customer may have paid Datalogic the required license fee; and
Customer’s use of the Software shall also be limited, as applicable and set forth in Customer’s purchase order or in Datalogic’s product catalog, user documentation, or web site, to a maximum number of (a) seats (i.e. users with access to the installed Software), (b) concurrent users, sessions, ports, and/or issued and outstanding IP addresses, and/or (c) central processing unit cycles or instructions per second. Customer’s use of the Software shall also be limited by any other restrictions set forth in Customer’s purchase order or in Datalogic’s product catalog, user documentation or web site for the Software.
2. General Limitations. Except as otherwise expressly provided under this Agreement, Customer shall have no right, and
Customer specifically agrees not to (i) transfer, assign or sublicense its license rights to any other person, or use the Software on unauthorized or secondhand Datalogic equipment, and any such attempted transfer, assignment or sublicense shall be void; (ii) correct errors to or otherwise modify or adapt the Software or create derivative works based upon the Software, or to permit third parties to do the same; or (iii) decompile, decrypt, reverse engineer, disassemble or otherwise reduce the Software to human-readable form to gain access to trade secrets or confidential information in the Software. To the extent required by law, at Customer's request, Datalogic shall provide Customer with the interface information needed to achieve interoperability between the Software and another independently created program, upon payment of Datalogic's applicable fee. Customer shall observe strict obligations of confidentiality with respect to such information.
3. Upgrades and Additional Copies. For purposes of this Agreement, “Software” shall include (and the terms and conditions of
this Agreement shall apply to) any upgrades, updates, bug fixes or modified versions (collectively, “Upgrades”) or backup copies of the Software licensed or provided to Customer by Datalogic or an authorized distributor for which Customer has paid the applicable license fees. Notwithstanding any other provision of this Agreement: (1) customer has no license or right to use any such additional copies or upgrades unless customer, at the time of acquiring such copy or upgrade, already holds a valid license to the original Software and has paid the applicable fee for the upgrade, if required; (2) use of upgrades is limited to Datalogic equipment for which customer is the original end user, purchaser or lessee or who otherwise holds a valid license to use the Software which is being upgraded; and (3) use of additional copies is limited to backup purposes only.
4. Proprietary Notices. Customer agrees to maintain and reproduce all copyright and other proprietary notices on all copies, in
any form, of the Software in the same form and manner that such copyright and other proprietary notices are included on the Software. Except as expressly authorized in this Agreement, Customer shall not make any copies or duplicates or any Software without the prior written permission of Datalogic. Customer may make such backup copies of the Software as may be necessary for Customer’s lawful use, provided Customer affixes to such copies all copyright, confidentiality, and proprietary notices that appear on the original.
5. Protection of Information. Customer agrees that aspects of the Software and associated documentation, including the
specific design and structure of individual programs, constitute trade secrets and/or copyrighted material of Datalogic. Customer shall not disclose, provide, or otherwise make available such trade secrets or copyrighted material in any form to any third party without the prior written consent of Datalogic. Customer shall implement reasonable security measures to protect such trade secrets and copyrighted material. Software and documentation shall remain solely property of Datalogic.
v
6. Limited Warranty. If Customer obtained the Software directly from Datalogic, then Datalogic warrants that during the
Warranty Period (as defined below): (i) the media on which the Software is furnished will be free of defects in materials and workmanship under normal use; and (ii) the Software will substantially conform to its published specifications. The “Warranty Period” means a period beginning on the date of Customer’s receipt of the Software and ending on the later of (a) ninety (90) days from the date of initial shipment of the Software by Datalogic, or (b) the end of the minimum period required by the law of the applicable jurisdiction. The limited warranties extend only to Customer as the original licensee. Customer's sole and exclusive remedy and the entire liability of Datalogic and its suppliers under these limited warranties will be, at Datalogic’s sole option, repair or replacement of the Software if reported (or, upon request, returned) to Datalogic. Except as expressly granted in this Agreement, the Software is provided AS IS and with all faults. Datalogic does not warrant that the Software is error free or that Customer will be able to operate the Software without problems or interruptions. In addition, due to the continual development of new techniques for intruding upon and attacking networks, Datalogic does not warrant that the Software or any equipment, system or network on which the Software is used will be free of vulnerability to intrusion or attack. This warranty does not apply if the Software (a) is licensed for beta, evaluation, testing or demonstration purposes for which Datalogic does not receive a license fee, (b) has been altered, except by Datalogic, (c) has not been installed, operated, repaired, or maintained in accordance with instructions supplied by Datalogic, (d) has been subjected to abnormal physical or electrical stress, misuse, negligence, or accident, or (e) is used in ultra hazardous activities. If Customer obtained the Software from a Datalogic reseller, the terms of any warranty shall be as provided by such distributor, and Datalogic provides Customer no warranty with respect to such Software. The Software may contain support for programs written in Java. Java technology is not fault tolerant and is not designed, manufactured, or intended for use or resale as online control equipment in hazardous environments requiring fail-safe performance, such as in the operation of nuclear facilities, aircraft navigation or communication systems, air traffic control, direct life support machines, or weapons systems, in which the failure of Java technology could lead directly to death, personal injury, or severe physical or environmental damage. Microsoft Inc. has contractually obligated Datalogic to make this disclaimer.
7. Disclaimer of Warranties. Except as specified in this warranty, all expressed or implied conditions, representations, and
warranties including, without limitation, any implied warranty or condition of merchantability, fitness for a particular purpose, non­infringement, satisfactory quality or arising from a course of dealing, usage, or trade practice, are hereby excluded to the extent allowed by applicable law. To the extent that an implied warranty cannot be excluded, such warranty is limited in duration to the warranty period.
8. Disclaimer of Liabilities. In no event will Datalogic or its suppliers be liable for any lost revenue, profit, or data, or for
special, indirect, consequential, incidental, or punitive damages however caused and arising out of the use of or inability to use the Software even if Datalogic has been advised of the possibility of such damages. In no event shall Datalogic or its suppliers' liability to customer, whether in contract, tort (including negligence), or otherwise, exceed the price paid by customer. The foregoing limitations shall apply even if the above-stated warranty fails of its essential purpose.
9. Term and Termination. This Agreement is effective until terminated. Customer may terminate this Agreement at any time by
destroying all copies of Software including any documentation. Customer’s license rights under this Agreement will terminate immediately without notice from Datalogic if Customer fails to comply with any provision of this Agreement. Upon termination, Customer must destroy all copies of Software in its possession or control.
10. Customer Records. Customer grants to Datalogic and its independent accountants the right to examine Customer’s books,
records and accounts during Customer’s normal business hours to verify compliance with this Agreement. In the event such audit discloses non-compliance with this Agreement, Customer shall promptly pay to Datalogic the appropriate license fees.
11. General Provisions. This Agreement shall be governed by and construed in accordance with the laws of Italy. All disputes
arising out of or in connection with this Agreement will be subject to the exclusive jurisdiction of the competent Court of the place where Datalogic has its registered office. If any portion hereof is found to be void or unenforceable, the remaining provisions of this Agreement shall remain in full force and effect. Except as expressly provided herein, this Agreement constitutes the entire agreement between the parties with respect to the license of the Software and supercedes any conflicting or additional terms contained in the purchase order.
vi
REFERENCES
CONVENTIONS
This manual uses the following conventions:
“User” refers to anyone using a Kyman-NET™ mobile computer. “Mobile computer” and "Kyman-NET™" refer to Kyman-NET™ mobile computer. “You” refers to the System Administrator or Technical Support person using this manual to install, configure, operate, maintain or troubleshoot a Kyman-NET™ mobile computer.
REFERENCE DOCUMENTATION
For further information regarding Kyman-NET™ refer to the SDK Help on-Line.
SERVICES AND SUPPORT
Datalogic provides several services as well as technical support through its website. Log on to www.datalogic.com and click on the links including:
indicated for further information
- PRODUCTS
Search through the links to arrive at your product page where you can download specific Manuals
and Software & Utilities
- SERVICES & SUPPORT
- Datalogic Services Warranty Extensions and Maintenance Agreements
- Authorised Repair Centres
- CONTACT US
E-mail form and listing of Datalogic Subsidiaries
vii
SAFETY REGULATIONS
Read this manual carefully before performing any type of connection to the Kyman-NET™ mobile computer. The user is responsible for any damages caused by incorrect use of
NOTE
GENERAL SAFETY RULES
Use only the components supplied by the manufacturer for the specific Kyman-NET™ being used.
Do not attempt to disassemble the Kyman-NET™ mobile computer, as it does not contain parts that can be repaired by the user. Any tampering will invalidate the warranty.
When replacing the battery pack or at the end of the operative life of the Kyman-NET™ mobile computer, disposal must be performed in compliance with the laws in force.
Do not submerge the Kyman-NET™ in liquid products.
For GSM models, when using the device for telephone calls, it is advised to use
a headset.
Avoid significant and rapid temperature variations, which can produce condensation inside the Kyman-NET™ and reduce its performance.
the equipment or by inobservance of the indication supplied in this manual.
viii
LASER SAFETY
The laser light is visible to the human eye and is emitted from the window indicated in the figure. This information applies to both laser models and the Kyman-NET™ Imager Aiming System.
Laser output window
I D F E
La luce laser è visibile all'occhio umano e viene emessa dalla finestra indicata nella figura.
LUCE LASER NON FISSARE IL FASCIO APPARECCHIO LASER DI CLASSE 2 MINIMA POTENZA DI USCITA: LUNGHEZZA D'ONDA EMESSA: CONFORME A EN 60825-1 (2001)
AVOID EXPOSURE
LASER LIGHT
IS EMITTED FROM
THIS APERTURE
CAUTION-CLASS 2 LASER LIGHT WHEN OPEN - DO NOT STARE INTO BEAM
Die Laserstrahlung ist für das menschliche Auge sichtbar und wird am Strahlaustrittsfenster ausgesendet (siehe Bild).
LASERSTRAHLUNG NICHT IN DER STRAHL BLINKEN PRODUKT DER LASERKLASSE 2 MAXIMALE AUSGANGLEISTUNG: WELLENLÄNGE: ENTSPR. EN 60825-1 (2001)
Le rayon laser est visible à l'oeil nu et il est émis par la fenêtre désignée sur l'illustration dans la figure.
RAYON LASER EVITER DE REGARDER LE RAYON APPAREIL LASER DE CLASSE 2 PUISSANCE DE SORTIE: LONGUER D'ONDE EMISE: CONFORME A EN 60825-1 (2001)
This product complies wit h
21 CFR Subchapter J
LASER LIGHT - DO NOT STARE INTO BEAM
CLASS 2 LASER PRODUCT
MAX. OUTPUT RADIATION 1.4 mW
EMITTED WAVELENGTH 630~680 nm
EN60825-1:2001
La luz láser es visible al ojo humano y es emitida por la ventana indicada en la figura.
RAYO LÁSER NO MIRAR FIJO EL RAYO APARATO LÁSER DE CLASE 2 MÁXIMA POTENCIA DE SALIDA: LONGITUD DE ONDA EMITIDA: CONFORME A EN 60825-1 (2001)
ix
ENGLISH
The following information is provided to comply with the rules imposed by international authorities and refers to the correct use of your mobile computer.
STANDARD LASER SAFETY REGULATIONS This product conforms to the applicable requirements of both CDRH 21 CFR 1040 and EN 60825-1 at the date of manufacture. For installation, use and maintenance, it is not necessary to open the device.
Use of controls or adjustments or performance of procedures other than those specified herein may result in exposure to hazardous
CAUTION
visible laser light.
The product utilizes a low-power laser diode. Although staring directly at the laser beam momentarily causes no known biological damage, avoid staring at the beam as one would with any very strong light source, such as the sun. Avoid that the laser beam hits the eye of an observer, even through reflective surfaces such as mirrors, etc.
ITALIANO
Le seguenti informazioni vengono fornite dietro direttive delle autorità internazionali e si riferiscono all’uso corretto del terminale.
NORMATIVE STANDARD PER LA SICUREZZA LASER Questo prodotto risulta conforme alle normative vigenti sulla sicurezza laser alla data di produzione: CDRH 21 CFR 1040 e EN 60825-1. Non si rende mai necessario aprire l’apparecchio per motivi di installazione, utilizzo o manutenzione.
L'utilizzo di procedure o regolazioni differenti da quelle descritte nella documentazione può provocare un'esposizione pericolosa
ATTENZIONE
a luce laser visibile.
Il prodotto utilizza un diodo laser a bassa potenza. Sebbene non siano noti danni riportati dall’occhio umano in seguito ad una esposizione di breve durata, evitare di fissare il raggio laser così come si eviterebbe qualsiasi altra sorgente di luminosità intensa, ad esempio il sole. Evitare inoltre di dirigere il raggio laser negli occhi di un osservatore, anche attraverso superfici riflettenti come gli specchi.
x
DEUTSCH
Die folgenden Informationen stimmen mit den Sicherheitshinweisen überein, die von internationalen Behörden auferlegt wurden, und sie beziehen sich auf den korrekten Gebrauch vom Terminal.
NORM FÜR DIE LASERSICHERHEIT Dies Produkt entspricht am Tag der Herstellung den gültigen EN 60825-1 und CDRH 21 CFR 1040 Normen für die Lasersicherheit. Es ist nicht notwendig, das Gerät wegen Betrieb oder Installations-, und Wartungs­arbeiten zu öffnen.
Jegliche Änderungen am Gerät sowie Vorgehensweisen, die nicht in dieser Betriebsanleitung beschrieben werden, können ein
ACHTUNG
gefährliches Laserlicht verursachen.
Der Produkt benutzt eine Laserdiode. Obwohl zur Zeit keine Augenschäden von kurzen Einstrahlungen bekannt sind, sollten Sie es vermeiden für längere Zeit in den Laserstrahl zu schauen, genauso wenig wie in starke Lichtquellen (z.B. die Sonne). Vermeiden Sie es, den Laserstrahl weder gegen die Augen eines Beobachters, noch gegen reflektierende Oberflächen zu richten.
FRANÇAIS
Les informations suivantes sont fournies selon les règles fixées par les autorités internationales et se refèrent à une correcte utilisation du terminal.
NORMES DE SECURITE LASER Ce produit est conforme aux normes de sécurité laser en vigueur à sa date de fabrication: CDRH 21 CFR 1040 et EN 60825-1. Il n’est pas nécessaire d’ouvrir l’appareil pour l’installation, l’utilisation ou l’entretien.
L'utilisation de procédures ou réglages différents de ceux donnés ici peut entrainer une dangereuse exposition à lumière laser
ATTENTION
visible.
Le produit utilise une diode laser. Aucun dommage aux yeux humains n’a été constaté à la suite d’une exposition au rayon laser. Eviter de regarder fixement le rayon, comme toute autre source lumineuse intense telle que le soleil. Eviter aussi de diriger le rayon vers les yeux d’un observateur, même à travers des surfaces réfléchissantes (miroirs, par exemple).
xi
ESPAÑOL
Las informaciones siguientes son presentadas en conformidad con las disposiciones de las autoridades internacionales y se refieren al uso correcto del terminal.
NORMATIVAS ESTÁNDAR PARA LA SEGURIDAD LÁSER Este aparato resulta conforme a las normativas vigentes de seguridad láser a la fecha de producción: CDRH 21 CFR 1040 y EN 60825-1. No es necesario abrir el aparato para la instalación, la utilización o la manutención.
La utilización de procedimientos o regulaciones diferentes de aquellas describidas en la documentción puede causar una
ATENCIÓN
exposición peligrosa a la luz láser visible.
El aparato utiliza un diodo láser a baja potencia. No son notorios daños a los ojos humanos a consecuencia de una exposición de corta duración. Eviten de mirar fijo el rayo láser así como evitarían cualquiera otra fuente de luminosidad intensa, por ejemplo el sol. Además, eviten de dirigir el rayo láser hacia los ojos de un observador, también a través de superficies reflectantes como los espejos.
LED Illuminator
The use of an illuminator in the Kyman-NET™ Imager is a Class 1 LED product:
xii
ILLUMINATORE LED CLASSE 1 AUSLEUCHTER LED KLASSE 1 ILLUMINATEUR A LED DE CLASSE 1 ILUMINADOR LED DE CLASE 1
RADIO COMPLIANCE
In radio systems configured with mobile computers and access points, the frequencies to be used must be allowed by the spectrum authorities of the specific country in which the installation takes place. Be absolutely sure that the system frequencies are correctly set to be compliant with the spectrum requirements of the country.
The Radio modules used in this product automatically adapt to the frequencies set by the system and do not require any parameter settings.
The following shows the correspondence between the Kyman-NET™ models and the Radio modules:
Kyman-NET™ 5XX-XXX 802.11b (Wi-Fi) radio card Kyman-NET™ X1X-XXX GSM/GPRS Tri-band (900, 1800, 1900 MHz) module Kyman-NET™ 51X-XXX 802.11b (Wi-Fi) radio card + GSM/GPRS Tri-band
(900, 1800, 1900 MHz) module
INFORMATION FOR THE USER
ENGLISH
Contact the competent authority responsible for the management of radio frequency devices of your country to verify the eventual necessity of a user license. Refer to the web site http://europa.eu.int/comm/enterprise/rtte/spectr.htm
ITALIANO
Prendi contatto con l'autorità competente per la gestione degli apparati a radio frequenza del tuo paese, per verificarne l'eventuale necessità della licenza d'uso. Inoltre puoi trovare ulteriori informazioni al sito:
http://europa.eu.int/comm/enterprise/rtte/spectr.htm
FRANÇAIS
Contactez l'autorité compétente en la gestion des appareils à radio fréquence de votre pays pour vérifier la nécessité du permis d'usage. Pour tout renseignement vous pouvez vous adresser au site web:
http://europa.eu.int/comm/enterprise/rtte/spectr.htm
DEUTSCH
Um die Notwendigkeit der Verwendungslizenz zu prüfen, wenden Sie sich an die Behörde, die auf der Radiofrequenzgerätsführung Ihres Lands bewandert ist. Weitere Informationen sind verfügbar auf dem Web Site:
http://europa.eu.int/comm/enterprise/rtte/spectr.htm
.
.
.
for further information.
xiii
ESPAÑOL
Contacta con la autoridad competente para la gestión de los dispositivos de radio frecuencia de tu país, para verificar si es necesario la licencia de uso. Además se puede encontrar mas información en el sitio web:
http://europa.eu.int/comm/enterprise/rtte/spectr.htm.
FCC COMPLIANCE
This device must be opened by qualified personnel only.
Modifications or changes to this equipment without the expressed written approval of Datalogic could void the authority to use the equipment.
This device complies with PART 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference which may cause undesired operation.
All Wi-Fi models contain FCC ID H9PLA4137.
ALL GSM/GPRS models contain FCC ID QIPMC55.
WEEE COMPLIANCE
xiv
GENERAL VIEW
B
C
D
E
I
A
F
G
H
A) Backlit display B) User programmable LED C) Speaker D) Good read LED E) Charging status and battery low
warning LED
F) Scan key
J
K
L
G) Keyboard H) Microphone I) Laser safety label J) Product label K) Adjustable elastic strap with stylus
holders
L) Battery pack
N
M
M) Data capture/Laser Output window N) Communication/Charger/Headset
connector
xv
xvi
INTRODUCTION
1
1 INTRODUCTION
1.1 KYMAN-NET™ DESCRIPTION
The Datalogic Kyman-NET™ rugged mobile computer is one of the key elements of Datalogic’s mobile@work™ product family for logistic solutions.
Kyman-NET™, thanks to the lightest weight of its category combined with one of the best ergonomics ever seen on the market, reduces the operators fatigue with no compromises in terms of reliability and robustness. Its sturdy outer casing with overmold protection has been designed to resist harsh environments, multiple drops, strong shocks, repetitive tumbles as well as sub-zero temperatures.
Datalogic’s Kyman-NET™ key features include fully integrated automatic data capture (1D bar code, 1D bar code & RFID HF-ISO tags, 1D & 2D bar codes & images), allowing codes to be read from near contact to several meters distance and simultaneous wireless communication capabilities (Bluetooth®, Wi-Fi, GSM/GPRS).
Kyman-NET™ system architecture is based on the “de-facto standard” combination of Intel X-Scale series processors coupled with the Windows CE operating system and it is ready to satisfy the most demanding customer needs (i.e. allowing to expand its memory thanks to a Secure Digital standard slot).
Kyman-NET™ provides 2 intuitive keyboard layouts, numeric/alphanumeric with backlight, able to fulfill 100% traditional text based applications (i.e. terminal emulation, through the DL-TCL-NET™ software client) as well as the most modern Web-based solutions (i.e. exploiting the Microsoft Internet Explorer through the DL Locked Web Browser™ application). Kyman-NET™ provides mobile professionals with the most relevant features needed to operate in demanding environments: reliability, ruggedness, drop resistance, long lasting batteries, flexible communication and efficient data capture.
1
1
KYMAN-NET™
1.2 AVAILABLE MODELS
The brand new Kyman-NET™ is available in different models depending on the options it is equipped with. All options are listed below:
data capture options: laser, imager, RfId, laser + RfId, laser extra-long range
communication options: Wi-Fi 802.11b, GSM/GPRS, Bluetooth®
data entry options: alphanumeric keyboard, numeric keyboard
For further details about the Kyman-NET™ models refer to the web site: http://www.datalogic.com
.
1.3 PACKAGE CONTENTS
The Kyman-NET™ package contains:
1 Kyman-NET™ mobile computer
1 CD-ROM Datalogic-NET SDK (Windows CE.NET SDK for Datalogic mobile
computers)
2 styluses
1 user’s manual
1 rechargeable battery pack
1 adjustable elastic strap with stylus holder
1 belt clip
1 belt clip pivot
Any other packages will contain the accessories necessary for the Kyman-NET™ connection to the host computer and to the network: the cradle, power supply, and one or more connection cables.
Remove all the components from their packaging; check their integrity and congruity with the packing documents.
CAUTION
2
Keep the original packaging for use when sending products to the technical assistance center. Damage caused by improper packaging is not covered under the warranty.
INTRODUCTION
Rechargeable battery packs are not initially charged. Therefore the first operation to perform is to charge them. See paragraph 4.1.
NOTE
1.3.1 Using the Belt Clip
To use the belt clip, proceed as follows:
1. Remove the elastic strap and unscrew the strap pivot.
1
2. Release the belt clip pivot by pressing the belt clip unlock button.
3
1
3. Screw the belt clip pivot on the terminal by using the fixing screw.
KYMAN-NET™
4. Insert the terminal in the belt clip by sliding the belt clip pivot into the belt clip until it clicks into place.
5. To release the terminal, press the belt clip unlock button.
4
INTRODUCTION
1.4 ACCESSORIES
Cradles
94A151101 Kyman-NET™ Single Cradle Desk (includes slot for spare battery pack recharge; RS232 and USB communications)
94A151107 Kyman-NET™ Vehicle Cradle
Charger
94A151102 Kyman-NET™ Multi-Battery Pack Charger (4 slots)
Batteries
94ACC1302 Kyman-NET™ Standard Battery Pack (Li-Ion battery pack 2200 mAh@7.4 V)
Power Supply
94ACC4595 FPS18 Power Supply without cord for Kyman-NET™ Single Cradle Desk, for Kyman-NET™ Multi-Battery Charger and for WIN-NET Serial/USB PWR Cables
94ACC1150 Power cord EU 3-pin
Cables
94A051008 WIN-NET SERIAL CABLE (HRS 3500-16P-CV) cable for RS232 direct connection between the mobile computer and the PC
94A051009 WIN-NET USB CABLE (HRS 3500-16P-CV) cable for USB direct connection between the mobile computer and the PC
94A051014 WIN-NET SERIAL PWR CABLE (HRS 3500-16P-CV) cable for RS232 and power connections
94A051015 WIN-NET USB PWR CABLE (HRS 3500-16P-CV) cable for USB and power connections
94A051012 WIN-NET VEHICLE PWR CAB (HRS 3500-16P-CV) cable for car/truck cigarette lighter power adapter
Various
94ACC1304 Kyman-NET™ Belt Holster 94ACC1303 Kyman-NET™ Functional Case 94ACC1301 Stylus Pen (20 pcs) 94ACC1300 JET™ & Kyman-NET™ Backstrap Kit (1+1 pcs)
1
5
2
KYMAN-NET™
2 CONNECTIONS
2.1 CONNECTION TO THE HOST COMPUTER
2.1.1 RS232/USB Direct Connection
You can use a cable to connect the Kyman-NET™ to a host computer to transfer data.
Key:
A Host computer C RS232 cable or USB cable B Kyman-NET™
Key:
A Host computer C RS232 cable or USB cable B Kyman-NET™ D Power Supply*
* Recommended Power Supply: FPS18 AC/DC Power Supply (94ACC4595).
USB communication may not be completely guaranteed while batteries are simultaneously in charge. Avoid the power supply
CAUTION
connection when the USB link is active.
6
CONNECTIONS
2
2.1.2 WLAN Connection
Kyman-NET™ Wi-Fi models can communicate with the host using the on-board radio frequency module and an Access Point connected to the host computer.
Key: A) Kyman-NET™ B) Access point
In order to avoid wasting power, the Wi-Fi module is off by default. If you need to have the Wi-Fi module working, the module must be powered on using the Wireless Communications applet (see par.
NOTE
3.7.4). To start configuring your WLAN connection, tap the Wi-Fi icon at the bottom of the screen.
7
2
2.1.3 WPAN Connections
Kyman-NET™ mobile computers can communicate with a Bluetooth a printer, within a range of 10 m, using the on-board Bluetooth
®
module.
KYMAN-NET™
®
device, such as
A
Key:
A) Kyman-NET™ B) Bluetooth
In order to avoid wasting power, the Bluetooth® module is off by default. If you need to have Bluetooth® working, the module must be powered on using the Wireless Communications applet (see par.
NOTE
3.7.4), and perform the Discovery procedure (see par. 3.8.2).
®
printer
B
8
Loading...
+ 55 hidden pages