D.a.s. DASNET-RACK99-230 User Manual

User's Manual
DASNET-RACK99-230
Antes de utilizar el equipo, lea la sección “Precauciones de seguridad” de este manual. Conserve este manual para futuras consultas.
Before operating the device, please read the “Safety precautions” section of this manual. Retain this manual for future reference.
CONTENTS
SAFETY PRECAUTIONS
WARRANTY
DECLARATION OF CONFORMITY
INTRODUCTION
CONFIGURATIONS
12 x AERO-40A + 8 UX-218A
12 x AERO-40A + 6 UX-221A
ANNEX I : Schematics
ANNEX II : DASnet cables
3
4
5
6 - 8
9 - 14
15 - 16
17
Manual del Usuario / DASNET-RACK99-230 / User’s Manual
DASNET-RACK 99-230
Caja de distribución para DASnet / DASnet Splitter
Precauciones de Seguridad Safety Precautions
El signo de exclamación dentro de un triángulo indica la existencia de importantes instrucciones de operación y mantenimiento en la documentación que acompaña al producto. Conserve y lea todas estas instrucciones. Siga las advertencias.
ATENCIÓN: Es un producto clase A, por lo que en entornos domésticos puede causar radio-interferencias, en cuyo caso el usuario tendrá que tomar las medidas oportunas. De acuerdo con EN55103-2, usar el equipo sólo en entornos E1, E2, E3 ó E4.
No desconecte la tierra en el conector de alimentación pues es peligroso e ilegal. Equipo de Clase I. El producto debe ser conectado a un enchufe con toma de tierra. Sólo use este equipo con el cable de red de alimentación adecuado para su país. El signo del rayo con la punta de flecha, alerta contra la presencia de voltajes peligrosos no aislados. Para reducir el riesgo de choque eléctrico, no retire la cubierta.
No instale el aparato cerca de ninguna fuente de calor como radiadores, estufas u otros aparatos que produzcan calor. Debe instalarse siempre sin bloquear la libre circulación de aire por las aletas del radiador.
No exponga este equipo a la lluvia o humedad sin el protector de lluvia recomendado. No exponga el equipo a salpicaduras sin el protector de lluvia recomendado, ni coloque sobre él objetos que contengan líquidos, tales como vasos y botellas.
Este símbolo indica que el presente producto no puede ser tratado como residuo doméstico normal, sino que debe entregarse en el correspondiente punto de recogida de equipos eléctricos y electrónicos.
The exclamation point inside an equilateral triangle is intended to alert the users to the presence of important operating and mainten ance (servi cing) instruc tions in the li terature accompanying the product. Heed all warnings. Follow all instructions. Keep these instructions. WARNING: This is a class A product. In a domestic environment this product may cause radio interferences in which case the user may be required to take adequate measures. Use this product only in E1, E2, E3 or E4 environments according to EN55103-2. Do not remove mains connector ground, it is dangerous and illegal. Class I device. The product must be connected to a mains socket outlet with protective earth connection. Only use this equipment with an appropriate mains cord for your country.
The lightning and arrowhead symbol warns about the presence of uninsulated dangerous voltage. To reduce the risk of electric shock, do not remove the cover.
Do not install near any heat sources such as radiators, heat registers, stoves or other apparatus that produce heat. The circulation of air through the heatsink must not be blocked.
Do not expose this device to rain or moisture without the rain protector supplied. Do not place any objects containing liquids, such as bottles or glasses, on the top of the unit. Do not splash liquids on the unit without the rain protector supplied.
This symbol on the product indicates that this product should not be treated as household waste. Instead it shall be handed over to the appicable collection point for the recycling of electrical and electronic equipment.
Equipo diseñado para funcionar entre 15ºC y 45ºC con una humedad relativa máxima del 95%, con un rango de ±10% de la tensión nominal de alimentación indicada en la etiqueta.
El cableado exterior conectado al equipo requiere de su instalación por una persona instruida o el uso de cables flexibles ya preparados.
Si el aparato es conectado permanentemente, la instalación eléctrica del edificio debe incorporar un interruptor multipolar con separación de contacto de al menos 3mm en cada polo.
Para desconectar el dispositivo debe usar el enchufe. Desconecte este aparato durante tormentas eléctricas, terremotos o cuando no se vaya a emplear durante largos periodos.
No existen partes ajustables por el usuario en el interior de este equipo. Cualquier operación de mantenimiento o reparación debe ser realizada por personal cualificado. Es necesario el servicio técnico cuando el equipo se haya dañado de alguna forma, como que haya caído líquido o algún objeto en el interior del aparato, haya sido expuesto a lluvia o humedad, no funcione correctamente, haya recibido un golpe o su cable de red esté dañado.
Limpie con un paño seco. No use limpiadores con disolventes. Clean only with a dry cloth. Do not use any solvent based
Working temperature ranges from 15ºC to 45ºC with a relative humidity of 95%, with ±10% of the rated main voltage value indicated on the label.
The outer wiring connected to the device requires installation by an instructed person or the use of a flexible cable already prepared.
If the apparatus is connected permanently, the electrical system of the building must incorporate a multipolar switch with a separation of contact of at least 3mm in each pole.
To disconnect the device, you should use the mains plug. Unplug this apparatus during lightning storms, earthquakes or when unused for long periods of time.
No user serviceable parts inside. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally or has been dropped.
cleaners.
Manual del Usuario / DASNET-RACK99-230 / User’s Manual
3
GARANTÍA
Todos nuestros productos están garantizados por un periodo de 24 meses desde la fecha de compra.
Las garantías sólo serán válidas si son por un defecto de fabricación y en ningún caso por un uso incorrecto del producto.
Las reparaciones en garantía pueden ser realizadas, exclusivamente, por el fabricante o el servicio de asistencia técnica autorizado.
Otros cargos como portes y seguros, son a cargo del comprador en todos los casos.
Para solicitar reparación en garantía es imprescindible que el producto no haya sido previamente manipulado e incluir una fotocopia de la factura de compra.
WARRANTY
All our products are warrantied against any manufacturing defect for a period of 2 years from date of purchase.
The warranty excludes damage from incorrect use of the product.
All warranty repairs must be exclusively undertaken by the factory or any of its authorised service centers.
To claim a warranty repair, do not open or intend to repair the product.
Return the damaged unit, at shippers risk and freight prepaid, to the nearest service center with a copy of the purchase invoice.
4
Manual del Usuario / DASNET-RACK99-230 / User’s Manual
DECLARACIÓN DE CONFORMIDAD
DECLARATION OF CONFORMITY
DAS Audio Group, S.L.
C/ Islas Baleares, 24 - 46988 - Pol. Fuente del Jarro - Valencia. España (Spain).
Declara que DASNET-RACK99-230: Declares that DASNET-RACK99-230:
Cumple con los objetivos esenciales de las Directivas: Abide by essential objectives relating Directives:
l de Baja Tensión (Low Voltage Directive) 2014/35/UE
l de Compatibilidad Electromagnética (EMC) 2014/30/UE
l RoHS 2011/65/UE
l RAEE (WEEE) 2012/19/UE
Y es conforme a las siguientes Normas Armonizadas Europeas: In accordance with Harmonized European Norms:
l EN 60065:2014.- Audio, video and similar electronic apparatus. Safety
requirements.
l EN 55032:2012.- Electromagnetic compatibility of multimedia equipment.
Emission requirements.
l EN 55103-2:2009.- Electromagnetic compatibility. Product family
standard for audio, video, audio-visual and entertainment lighting control apparatus for professional use. Part 2:Immunity.
l EN 50581:2012.- Technical documentation for the assessment of
electrical and electronic products with respect to the restriction of hazardous substances.
Manual del Usuario / DASNET-RACK99-230 / User’s Manual
5
INTRODUCTION
The DASNET-RACK99-230, assembled in a 19", 8U high rack, is composed of three elements: 1x DASNET-MATRIX99, 1x DASNET-PATCH-PW-9 and 1x DISTRO-RACKNET-32-9 (all described in the following sections of this manual). Knowing the needs required by the system in terms of distribution of power, currents and supply voltages and electrical safety guidelines, will be essential for a safe use of this rack.
Caution: Before connecting to the mains make sure that all electrical safety specifications and guidelines are met, and that all the safety warnings have been given due attention.
PUSH
PUSH
PUSH
231
231
OUT
2
OUT
3
Matrix 9X9
230/115 V~
MAX.16A per OUT
231
LINK 1&2 LINK 2&3 LINK 3&4 LINK 4&5 LINK 5&6 LINK 6&7 LINK 7&8 LINK 8&9
OUT
1
PH.1 PH.2 PH.3
DISTRO-RACKNET-32-9
FI-Schalter
I
FI4030mA 4pol.
AUDIO IN
PUSH
231
AUDIO / DASNET OUT
8U high rack
DASNET-MATRIX99
DASNET-PATCH-PW-9
TERMINATION
POWER
ON
OUT
RESISTOR
OUT
PUSH
231
ON
2
1
3
2
3
PUSH
PUSH
231
OUT
1
PUSH
231
231
OUT
2
OUT
3
PUSH
PUSH
231
231
OUT
1
1U high panel
DISTRO-RACKNET-32-9
DASNET-RACK99-230
The DISTRO-RACKNET-32-9 allows the distribution of power between the different equipment that form the system in a simple and safe way, and consists of:
L2
L1 PE
FI-Schalter
I
FI4030mA 4pol.
L3
C
L2
L1
N
PE
Frontal View Rear View
B
Manual del Usuario / DASNET-RACK99-230 / User’s Manual
E
D
L3
N
A
A.- Three phase connector type IEC60309 or cetac, 32A / 400V for the input.
B.- Three phase connector type IEC60309 or cetac, 32A / 400V for the output (looped with the input).
C.- Phase 1, Phase 2 , Phase 3 breakers (one per ouput; total 9 units). The breakers are 16A nominal current (In), type C (max Peak current > 5In).
D.- Phase LEDS. Indicate power per phase.
E.- Schuko outputs. There are 3 outputs per phase. There is one Auxiliary output connected in
parallel to the output 1 of phase 1 (max. 10W).
6
DASNET-PATCH-PW-9
The DASNET-PATCH-PW-9 provides AC power up to 9 connected devices, in a simple and safe manner, using Neutrik connectors type PowerCon True1. The information on the AC voltage range of the power supply and the maximum current available for each output is shown on the silkscreen.
Voltage range and max. current per output
LED indicates Phase has power
Neutrik PowerCon True1 connector
230/115 V~
MAX.16A per OU T
OUT
1
PH.1 PH.2 PH.3
OUT
OUT
2
3
OUT
1
OUT
OUT
2
3
OUT
1
OUT
OUT
2
3
Outputs connected to Phase 1: L1 Outputs connected to Phase 2: L2 Outputs connected to Phase 3: L3
On the rear of DASNET-PATCH-PW-9, a total of 9 cables with schuko are located. Each one of the cables with its corresponding schuko must be connected to each output of the DISTRO-
RACKNET-32-9. On the other hand, the Schuko Auxiliary output of this will serve to power the DASNET-MATRIX99.
DASNET-MATRIX99
The DASNET-MATRIX99 distribution module routes 9 balanced audio channels and DASnet monitoring data up to 9 “zones” or clusters with self-powered DAS Audio systems.
Switch to active termination resistor
RS-485 IN:
PUSH
231
TERMINATION
RESISTOR
POWER
POWER
ON
ON
PUSH
231
ON
2
1
3
FRONT PANEL
PUSH
231
Matrix 9X9
AUDIO IN: Female XLR type connectors
PUSH
231
LINK 1&2 LINK 2&3 LINK 3&4 LINK 4&5 LINK 5&6 LINK 6&7 LINK 7&8 LINK 8&9
PUSH
231
AUDIO IN
PUSH
231
AUDIO / DASNET OUT
PUSH
231
PUSH
231
Female XLR type connector
PUSH
231
PUSH
231
Link switch for the inputs of the matrix
AUDIO / DASNET OUT: Neutrik EtherCon connectors
LED ON
RS-485 OUT:
Male XLR type connector
On the front panel of DASNET-MATRIX99 we can view three connector types: The first, AUDIO IN, female XLR type for 9 balanced audio inputs. The panel includes 8 link switches for routing audio from inputs to outputs. By the use of the switches one unique audio signal can be routed to all ethercon outputs (per example).
The second, AUDIO / DASNET OUT, Neutrik etherCon type to distribute audio and monitoring data to the different groups of self powered cabinets, 9 DASnet output connectors.
Finally we have the RS-485 connectors, which allow us to join several matrix to form a network with RS-485 protocol. Between the connectors the end-of-line switch is observed.
REAR PANEL
AC INPUT
100-230V~ 50/60Hz
10W
Neutrik PowerCon True1 connector
2
2
2
1
1
3
1
3
3
2
1
3
AUDIO OUT: Male XLR type connectors
AUDIO OUT
2
1
2
1
3
1
3
3
2
2
1
3
2
1
3
On the rear panel, using a power cable, the DASNET-MATRIX99 will be connected to the Schuko Auxiliary output of the DISTRO-RACKNET-32-9. This cable has a Neutrik connector type PowerCon True1 at one end and an F type (CEE 7/7) plug at the other. In addition, we have 9 balanced audio outputs that are in parallel with the inputs.
Manual del Usuario / DASNET-RACK99-230 / User’s Manual
7
Internally, each DASNET-MATRIX99 has an RS-485 repeater that is directly connected after the RS-485 input. The repeater allows having larger distances of cabling in the network and a much higher number of devices without loosing capabilities.
The DASNET-MATRIX99 is an ideal solution for audio and monitoring data distribution in self powered cabinets that include DASnet: AERO-20A, AERO-40A, UX-221A, UX-30A, UX-218A, UX- 218A-R, LX-218CA-NET, ROAD-12A-NET, ROAD-15A-NET, etc.
There is a termination resistor which can be activated with a sw itc h. It is recommendable to engage it in the first and last matrix of the network to increase network stability. With this system, ideal solution for touring, we can link a maximum number of 144 devices, with a maximum total length of the DASnet data cable should not exceed 1000 meters (counting both XLR data cables and ecp_xx CAT 7 cables).
Example of typical touring network with standard RS-485
DASnet
USB-RS485
The RS-485 protocol needs a USB to RS-485 converter. This converter is provided by DAS Audio with every system pruchased. The USB to RS-485 converter has to be connected to the DASNET- MATRIX99 using the IN RS-485 connector.
zone 1
Matrix 9X9
“Terminator resistor” activated
PUSH
PUSH
231
231
LINK 1&2 LINK 2&3 LINK 3&4 LINK 4&5 LINK 5&6 LINK 6&7 LINK 7&8 LINK 8&9
AUDIO IN
PUSH
PUSH
231
PUSH
231
AUDIO / DASNET OUT
231
zone 2
PUSH
PUSH
231
231
LINK 1&2 LI NK 2&3 LINK 3&4 LINK 4&5 LINK 5&6 LINK 6&7 LINK 7&8 LINK 8&9
Matrix 9X9
AUDIO IN
PUSH
PUSH
231
PUSH
231
AUDIO / DASNET O UT
231
“Terminator resistor” activated
PUSH
PUSH
231
231
LINK 1&2 LI NK 2&3 LINK 3&4 LINK 4&5 LINK 5&6 LINK 6&7 LINK 7&8 LINK 8&9
Matrix 9X9
AUDIO IN
PUSH
PUSH
231
PUSH
231
AUDIO / DASNET O UT
231
PUSH
PUSH
231
PUSH
231
PUSH
231
PUSH
231
231
PUSH
PUSH
231
231
PUSH
PUSH
231
231
PUSH
PUSH
231
231
TERMINATION
RESISTOR
ON
2
1
POWER
ON
3
PUSH
PUSH
231
231
TERMINATION
RESISTOR
ON
2
1
POWER
ON
3
PUSH
PUSH
231
231
TERMINATION
RESISTOR
ON
2
1
POWER
ON
3
On the other hand, the DASNET-MATRIX99 offers flexible routing with switches on the front panel that allow you to mount an audio input to several outputs. The nine audio inputs can be linked directly to their corresponding ethercon outputs. In addition, a single audio input can be linked to all ethercon outputs by using the switches. That is, if you look at the figure below, we have linked the inputs 1 with 2 on one side and 2 with 3 on the other. With this, it is enough to enter audio through connector 1 to output that signal through all the connected output connectors: 1, 2 and 3, both ethercon on the front, and XLR on the rear. With this system, we can send a signal to all the equipment (linking all the outputs with the input 1) or create several zones with different signal sends.
Matrix 9X9
PUSH
231
PUSH
231
LINK 1&2 LINK 2&3 LINK 3&4 LINK 4&5 LINK 5&6 LINK 6&7 LINK 7&8 LINK 8&9
PUSH
231
AUDIO IN
PUSH
231
PUSH
231
PUSH
231
PUSH
231
AUDIO / DASNET OUT
PUSH
231
PUSH
231
TERMINATION
RESISTOR
POWER
POWER
ON
ON
PUSH
231
ON
2
1
3
Example of input links
8
Manual del Usuario / DASNET-RACK99-230 / User’s Manual
CONFIGURATIONS
Example 1 : 12 x AERO-40A + 8 x UX-218A
2 x eCPK_20
2 x eCPK_20
L R
AUDIO IN
2
2
2
2
1
1
1
1
3
3
3
3
LINK 1&2 LINK 2&3 LINK 3&4 LINK 4&5 LINK 5&6 LINK 6&7 LINK 7&8 LINK 8&9
Matrix 9X9
AUDIO / DASNET OUT
OUT2OUT
1
MAX. 20A/ OUT
OUT
3
PH.1 PH.2 PH.3
FI-Schalter
I
FI4030mA4pol.
2 x eCPK_20 2 x eCPK_20
DASN ET-RAC K99-230
2
2
1
1
1
3
3
3
OUT1OUT
OUT2OUT
1
2
OUT3OUT
3
PUSH
231
2
2
2
1
1
3
3
ON
2
1
POWER ON
3
2 x eCPk_1
2 x eCPk_1
This is the recommended power distribution of the example configuration:
FROM 3 x AE RO-40A L
FROM 3 x AE RO-40A L
FROM 2 x U X-218A L
FROM 2 x U X-218A L
2
1
3
LINK 1&2 LINK 2&3 LINK 3&4 LINK 4&5 LINK 5&6 LINK 6&7 LINK 7&8 LINK 8&9
Matrix 9X9
OUT2OUT
1
MAX.
20A/ OUT
PH.1 PH.2 PH.3
AUDIO IN
2
2
2
1
1
1
1
3
3
3
3
AUDIO / DASNET OUT
OUT
1
OUT
3
FI-Schalter
I
FI4030mA4pol.
PUSH
2
2
1
1
3
3
OUT
2
OUT
3
231
2
2
2
1
1
3
3
ON
2
1
POWER
ON
3
OUT
OUT
1
2
OUT
3
FROM 3 x AE RO-40A R
FROM 3 x AE RO-40A R
FROM 2 x U X-218A R
FROM 2 x U X-218A R
Load per Phase:
Phase 1 = 3 x 3A + 3 x 3A + 3 x 3A = 27A
Phase 2 = 3 x 3A + 2 x 4,5A + 2 x 4,5A = 27A
Phase 3 = 2 x 4,5A + 2 x 4,5A = 18A
As we have indicated the DASNET-RACK99-230 allows a power distribution of up to 32Amp per phase (three-phase). Every 3 outputs of the DISTRO-RACKNET-32-9 of power are connected to a single phase. This means that of each group of 3 PowerCon True 1 connectors, the maximum available current is 32A. The user must always consider the power consumption of the equipment (specified at 1/3 of the nominal power with pink noise) connected to each output and DO NOT exceed the limit of 32A for each group of 3 PowerCon outputs.
Manual del Usuario / DASNET-RACK99-230 / User’s Manual
9
With the system configurations, DAS Audio recommends the maximum number of
cabinets that can be connected depending on the model, the power consumption and the total equipment used (see table below).
Consumption per unit
AERO-20A
AERO-40A
UX-218A
UX-221A
UX-30A
LX-118A
LX-218CA-NET
ROAD-12A-NET
ROAD-15A-NET
Mains
230V
1,8A
3A 6A
4,5A 9A
9A 18A
6,7A 13,4A
3A 6A
3,1A
(1)
1,7A
(2)
1,7A
115V
3,6A
6,2A
3,4A
3,4A
Note: C o n s u m p t i o n me a s u red a t 1/3 o f n o m i n a l p o w e r w i t h pi n k n o i s e .
( 1 ) Mode l s : ROAD-12ART-NET230, ROAD-12ALT-NET230, ROAD-12ART-NET115, ROAD-12ALT-NET115 (2) Models: ROAD-15ART-NET230, ROAD-15ALT-NET230, ROAD-15ART-NET115, ROAD-15ALT-NET115
MODEL: DASNET-RACK99-230
DAS Audio Group, S.L. (Valencia) MADE IN SPAIN
Rated Voltage:
Rated Current: 32A IP rating: IP20
S/N
3/N/PE 400/230 V
50Hz/60Hz
www.dasaudio.com
10
Label of DASNET-RACK99-230
Manual del Usuario / DASNET-RACK99-230 / User’s Manual
USB-RS485 Converter
x 1
243cm / 96”
228cm / 90”
4 x aero40
4 x aero40 4 x aero40
4 x aero40
4 x aero40
251cm / 99”
4 x aero40
Dollies
x 3
PL-40S metal transport dolly for 3 or 4 AERO-40A
x 1
4 x aero40 4 x aero40
UX-218A
UX-218A
DSP-4080
Euro truck Euro truck
Processors (included in the racks)
12 AERO-40A + 8 UX-218A 12 AERO-40A
243cm / 96”
4 x aero40 4 x aero40
4 x aero40 4 x aero40
UX-218A
UX-218A
228cm / 90”
UX-218A
UX-218A
4 x aero40
UX-218A
4 x aero40
4 x aero40
UX-218A
American Truck 90” x 232” American Truck 90” x 232”
UX-218A
UX-218A
UX-218A
4 x aero40 4 x aero40
UX-218A
4 x aero40
American Truck 99” x 232” American Truck 99” x 232”
251cm / 99”
x 4
x 8
A40 Accessories
Speaker cabling
eCPK_20 (CAT 7 ethernet cable + 3x2.5mm2, audio +data + power, 20m length)
x 8
x 8
eC_09 (CAT 7 ethernet cable; audio +data, 90cm length)
x 4
1
3
PUSH
2
RESISTOR
TERMINATION
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
AUDIO IN
2
3
1
2
3
1
2
3
1
LINK 1&2 LINK 2&3 LINK 3&4 LINK 4&5 LINK 5&6 LINK 6&7 LINK 7&8 LINK 8&9
2
3
1
Plink1_09 (power link 2.5mm2 90cm)
DASNET-RACK99
eCPk_1 (ethernet cable)
ON
2
3
1
ON
POWER
AUDIO / DASNET OUT
Matrix 9X9
Manual del Usuario / DASNET-RACK99-230 / User’s Manual
x 3
x 4
x 1
3
2
OUT
OUT
1
OUT
3
2
OUT
OUT
1
OUT
FI4030mA4pol.
FI-Schalter
3
2
OUT
OUT
1
PH.1 PH.2 PH.3
OUT
MAX.
16A/ OUT
I
Covers
FUN-4-AE40 is a protective nylon cover for 4 AERO-40A
Rigging frames
FUN-2-UX218 nylon cover for a stack of 2 UX-218A
x 2
AX-AE40S3
Dollies
PL-UX218S
The PL-UX218S dolly is used to
transport stacks of 2 or 3 UX-218A.
11
LINK LINK LINK LI NK
LINKLINKLINKLINK
Example 2 : 12 x AERO-40A + 6 x UX-221A
2 x eCPK_20
2 x eCPK_20
USB-RS485 converter
L R
EDIT
DSP-4080
ON
2
1
3
3
PUSH
2
1
3
2
OUT
RESISTOR
OUT
ON
POWER
TERMINATION
2
3
1
1
OUT
2
3
1
2
3
1
3
2
2
OUT
OUT
3
1
2
3
1
1
OUT
AUDIO IN
AUDIO / DASNET OUT
2
3
1
2
3
1
2
3
1
LINK 1&2 LINK 2&3 LINK 3&4 LINK 4&5 LINK 5&6 LINK 6&7 LINK 7&8 LINK 8&9
2
3
1
Matrix 9X9
ON
2
1
3
3
PUSH
2
1
RESISTOR
ON
POWER
TERMINATION
2
3
1
2
3
1
2
3
1
2
3
1
2
3
1
AUDIO IN
AUDIO / DASNET OUT
2
3
1
2
3
1
2
3
1
LINK 1&2 LINK 2&3 LINK 3&4 LINK 4&5 LINK 5&6 LINK 6&7 LINK 7&8 LINK 8&9
2
3
1
Matrix 9X9
FI4030mA4pol.
FI-Schalter
I
3
2
OUT
OUT
1
PH.1 PH.2 PH.3
OUT
MAX.
16A/ OUT
3
2
OUT
OUT
1
OUT
3
2
OUT
OUT
1
OUT
3
2
OUT
OUT
1
PH.1 PH.2 PH.3
OUT
MAX.
16A/ OUT
DASNET-RACK-99
FI4030mA4pol.
FI-Schalter
I
DASNET-RACK-99
3 x eCPK_20
3 x eCPK_20
LINK LINK LINK LINK
LINKLINKLINKLINK
12
Manual del Usuario / DASNET-RACK99-230 / User’s Manual
PHASE 1: 18A
PHASE 2: 18A
PHASE 3: 9A
LOAD PER PHASE
FROM 1 x UX-221A R
FROM 1 x UX-221A R
FROM 1 x UX-221A R
ON
2
1
3
3
PUSH
2
1
3
2
OUT
OUT
RESISTOR
ON
POWER
TERMINATION
2
3
1
2
1
2
1
2
1
2
1
AUDIO IN
2
1
2
1
2
1
2
1
1
OUT
3
3
3
2
OUT
OUT
3
3
1
OUT
AUDIO / DASNET O UT
3
FI4030mA 4pol.
FI-Schalter
3
3
LINK 1&2 LINK 2&3 LINK 3&4 LINK 4&5 LINK 5&6 LINK 6&7 LINK 7&8 LINK 8&9
3
Matrix 9X9
3
2
OUT
OUT
1
PH.1 PH.2 PH.3
OUT
MAX.
16A/ OUT
I
DASNET-RACK-99
ON
2
1
3
3
PUSH
2
1
3
2
OUT
OUT
RESISTOR
ON
POWER
TERMINATION
2
3
1
2
1
2
1
2
1
2
1
AUDIO IN
2
1
2
1
2
1
2
1
FROM 1 x UX-221A L
FROM 3 x AERO-40A L FROM 3 x AERO-40A R
FROM 3 x AERO-40A L FROM 3 x AERO-40A R
FROM 1 x UX-221A L
FROM 1 x UX-221A L
1
OUT
3
3
3
2
OUT
OUT
3
3
1
OUT
AUDIO / DASNET OUT
3
FI4030mA 4pol.
FI-Schalter
PHASE 2: 18A
PHASE 3: 9A
I
3
3
LINK 1&2 LINK 2&3 LINK 3&4 LINK 4&5 LINK 5&6 LINK 6&7 LINK 7&8 LINK 8&9
3
Matrix 9X9
3
2
OUT
OUT
1
PH.1 PH.2 PH.3
OUT
MAX.
16A/ OUT
PHASE 1: 18A
DASNET-RACK-99
LOAD PER PHASE
Manual del Usuario / DASNET-RACK99-230 / User’s Manual
13
x 1
243cm / 96”
228cm / 90”
251cm / 99”
USB-RS485 Converter
x 3
x 1
DSP-4080
12 AERO-40A
4 x aero40
4 x aero40
4 x aero40
4 x aero40
243cm / 96”
4 x aero40
4 x aero40
3 x UX-221A3 x UX-221A
4 x aero404 x aero40
3 x UX-221A3 x UX-221A
4 x aero40
4 x aero40
4 x aero40
4 x aero40
228cm / 90”251cm / 99”
4 x aero40
4 x aero40
4 x aero40
3 x UX-221A
3 x UX-221A
4 x aero40 4 x aero40
4 x aero40
x 10
A40 Accessories
Speaker cabling Dollies
14
Processors (included in the racks)
PL-40S metal transport dolly for 3 or 4 AERO-40A
x 8
x 8
eCPK_20 (CAT 7 ethernet cable + 3x2.5mm2, audio +data + power, 20m length)
eC_09 (CAT 7 ethernet cable; audio +data, 90cm length)
12 AERO-40A + 6 UX-221A
1
3
PUSH
2
2
1
2
1
2
1
2
1
2
1
AUDIO IN
2
1
2
1
2
1
2
1
Plink1_09 (power link 2.5mm2 90cm)
DASNET-RACK99
Manual del Usuario / DASNET-RACK99-230 / User’s Manual
Euro Truck 6m Trailer
ON
2
3
1
RESISTOR
ON
POWER
TERMINATION
3
3
3
3
3
3
3
3
LINK 1&2 LINK 2&3 LINK 3&4 LINK 4&5 LINK 5&6 LINK 6&7 LINK 7&8 LINK 8&9
3
Matrix 9X9
AUDIO / DASNET OUT
American Truck 90” x 232”
American Truck 99” x 232”
x 2
x 3
x 2
x 2
3
2
OUT
OUT
1
OUT
3
2
OUT
OUT
1
OUT
FI4030mA4pol.
FI-Schalter
3
2
OUT
OUT
1
PH.1 PH.2 PH.3
OUT
MAX.
16A/ OUT
I
Covers
FUN-4-AE40 is a protective nylon cover for 4 AERO-40A
Rigging frames
FUN-3-UX221 nylon cover for a stack of 3 UX-221A
x 2
AX-AE40S3
Dollies
PL-221S
The PL-221S dolly is used to
transport stacks of 2 or 3 UX-221A.
ANNEX I : Schematics
_
_ _
_
_
_
L1 L3L2
N L2L1 L3 N L2L1 L3
_
_
_
RCD
40A/30mA
____
_ _ _
_ _
_
_ _
_ _ _
_ _ _
OUT (Looped)IN
PC 230V 16A
___
_
_
PC 230V 16A PC 230V 16A PC 230V 16A PC 230V 16A PC 230V 16A PC 230V 16A PC 230V 16A PC 230V 16APC 230V 16A
_
_
_
_
_
_
_
_
_
_
PH3.1 PH3.2 PH3.3PH2.3PH2.2PH2.1PH1.3PH1.2PH1.1AUX
DISTRO-RACKNET-32-9
Manual del Usuario / DASNET-RACK99-230 / User’s Manual
_
_
_
_
_
15
1.0
16
Manual del Usuario / DASNET-RACK99-230 / User’s Manual
ANNEX II : DASnet cables
It is very important to use the system with the intended cables to prevent electromagnetic interferences between the analog audio signal, the DASnet data and the power. Be sure to check the specifications provided by the cable manufacturer. It is also especially important when installing connectors yourself, to note that when termination is not accurate, a cable will be unable to achieve its maximum performance and could have interferences.
There are 4 different types of cables.
- The main feeds which include power and a STP, CAT7 cable. These cables are named eCP_xx (xx refers to cable length).
- The links between cabinets (aero40A/Convert15A/LX-218CAnet), which are STP CAT7 cables. Cable code eC_09
- Power Links between cabinets.Cable code Plink1_09
- Links for RoadNet series. Power+STP CAT7. eCPk_1/eCPk_5
Important
The main feed cable eCP_xx has the following structure:
Jacket
STP CAT 7 cable with Aluminium Shield for each individual pair
AL Shield
and a main aluminium Shield. The main Shield has to be soldered to the etherCon housing.
The eC_09 cable is a CAT5e cable with global Aluminium Shield.
ecP_xx: Power cable 3x2.5mm + CAT7 4x (2 x 0.14mm )
The pin out of the EtherCon to XLR is the following on the eCP cables:
etherCon XLR
1 Orange-White Audio+ 2 2 Orange Audio- 3 3 Green-White Audio Earth 1 4 Blue 5 Blue-White 6 Green Data Earth 1 7 Brown-White Data- (A) 3 8 Brown Data+ (B) 2
Jacket
2 2
Manual del Usuario / DASNET-RACK99-230 / User’s Manual
17
www.dasaudio.com
UM_RACK991_01_EN
DAS Audio Group, S.L.
C/. Islas Baleares, 24 46988 Fuente del Jarro Valencia, SPAIN Tel. +34 96 134 0860
DAS Audio of America, INC.
6900 NW 52th Street Miami, FL. 33166 - U.S.A. TOLL FREE: 1 888 DAS 4 USA
DAS Audio Asia PTE. LTD.
3 Temasek Avenue, Centennial Tower #34-36 Singapore 039190 Tel. +65 6549 7760
DAS do Brasil LTDA.
Rua Dos Andradas, 382 SL Santa Efigênia, São Paulo Brasil. CEP: 01208-000 Tel. +551133330764
Loading...