Artec series
Artec 526
LOUDSPEAKER SYSTEM
The D.A.S. Artec 526 is a Two-way vented
loudspeaker system designed for
applications covering speech reinforcement
and program reproduction.
The low end utilizes two high efficiency 6”
low frequency speakers with 2” voice coil.
The high end makes use of a 1” exit
compression driver with 1.75” titanium
diaphragm, coupled to a 80º x 80º horn.
TWO-WAY VENTED
>> Two-way vented
loudspeaker system
>> 2 x 6” cone speaker
>> 1” exit compression
driver with constant
directivity horn
>> 400 W power handling
The unit has a robust grille design
internally lined with acoustically
transparent filter cloth to protect the
loudspeaker components. The covering is
resistant to wear and tear, provides
protection from dust and dirt.
4 integrated rigging points that accept
10M forged steel eyebolts or “U” braket
make suspension in either the horizontal
or vertical positions safe and simple.
Technical Specifications
RMS (Average) Power Handling
Program Power Handling
Peak Power Handling
On-axis Frequency Range
Nominal Impedance
Minimum Impedance
On-axis Sensitivity 1W/1m
Rated Peak SPL at Full Power
Nominal -6dB Beamwidths
Enclosure Material
Finish
Transducers/Replacement Parts
Connector
Dimensions (H x W x D)
Weight
Accesories (optional)
P
K
R
400 W
800 W
1600 W
60 Hz - 20 kHz
16 Ohms
LF, 13.4 Ohms @ 200 kHz
93 dB SPL
125 dB SPL
80º Horizontal x 80º Vertical
Wisa® Birch Plywood
Isoflex Black Paint
LF: 2 x 6P / 6P
HF: M34 / GM-M-34
2 paralleled NL4 Speakon,
wired to +/-1
54.5 x 19.4 x 25.5 cm
21.3 x 7.7 x 10 in
9 kg
ANL-2
TRD-6 + AXC-ZT
TRD-2 + AXC-ZT
AXU-A526
AXW-1
AXR-A500
Dimensions
255
194
ALL SIMENSIONS IN MILIMETERS
R
Based on a 2 hour test using a 6dB crest factor pink noise signal
P
Conventionally, 3dB higher than the RMS measure
k R
Corresponds to the signal crests for the test described in
545

Artec 526 Artec series
Frequency Response
Shows the frequency response
at 1m of a unit radiating to
an anechoic environement (4p)
and driven by a 1w (4 V) swept
sine signal, and impedance curve.
For better detail, only light
smoothing (1/12th octave)
has been used.
Distortion
Shows the Second Harmonic
Distortion(grey) and Third
Harmonic Distortion (dotted)
curvesfor a unit driven at 10%
of its nominal power rating.
Rised 20dB for clarity.
Directivity
Shows normalized horizontal
isobar plot
110.0
dBSPL
100.0
90.0
80.0
70.0
60.0
10 100 1k 10k 20k10 Hz
120.0
dBSPL
110.0
100.0
90.0
80.0
70.0
10 100 1k 10k 20k10 Hz
150.0
Ohm
120.0
90.0
60.0
30.0
0.0
0
dB
-10
-20
Directivity
Shows normalized vertical
isobar plot
Polar Response
1/3 octave band horizontal (left)
and vertical (right) polars for
the indicated frequencies. Full
scale is 30dB, 6dB per division.
180.0
120.0
60.0
60.0
120.0
180.0
-30
-40
500200
0
500200
125Hz
250Hz
500Hz
1000Hz
2000Hz
4000Hz
8000Hz
12500Hz
Left
-30°
-60°
-90°
-120°
6
dB
0
-6
-12
-18
-24
1k
1k
Right
30°
60°
90°
120°
2k
2k
180°
Ref 0 1/3 Octave
5k100 10k 12k5 Hz
5k100 10k 12k5 Hz
-120°
-150°
150°
-90°
-60°
-6
-18
-12
-24
-50
0
dB
-10
-20
-30
-40
-50
Up
-30°
Directivity
dB
0
6
30°
-150°
NOTES: Frequency response measured at 4m (13.12ft). For better detail, only light smoothing
(1/12th octave) has been used. Polars were acquired by placing the unit on a computer controlled
turntable inside a 300 m (10594 ft ) anechoic chamber. Measurement distance is 4m (13.12ft).
3 3
180°
Ref 0 1/3 Octave
150°
Product improvement through research and development is a
continuous process at D.A.S. Audio. All specifications subject
to change without notice.
120°
90°
60°
Down