D.A.S. Action-8A, Action Series, Action-12A, Action-15A, Action-215A User Manual

...
Page 1
User's Manual
ACTION-8A / ACTION-12A / ACTION-M12A / ACTION-15A
ACTION-215A / ACTION-18A / ACTION-118A / ACTION-218A
Antes de utilizar el equipo, lea la sección “Precauciones de seguridad” de este manual. Conserve este manual para futuras consultas.
Before operating the device, please read the “Safety precautions” section of this manual. Retain this manual for future reference.
Page 2
CONTENTS
SAFETY PRECAUTIONS
WARRANTY
DECLARATION OF CONFORMITY
INTRODUCTION
CONFIGURATIONS
2x ACTION-8A
2x ACTION 8A + 1x ACTION18A
2x ACTION-8A + 2x ACTION-18A
2x ACTION-12A (ACTION-15A)
2x ACTION-12A (ACTION-15A) + 1x ACTION-18A
2x ACTION-12A (ACTION-15A) + 2x ACTION-18A
2x ACTION-12A (ACTION-15A) + 2x ACTION-218A
2x ACTION-215A
4x ACTION-M12A
LINE DRAWINGS
SPECIFICATIONS
AMPLIFIER
Description
ON / OFF
3
4
5
6 - 7
8 - 16
17 - 18
18
16 - 21
Overload indicators
Equalisation
Overheating
Low mains voltage
Current consumption
Troubleshooting
RIGGING SYSTEM
ANNEX
Line connections: unbalanced and balanced
22 - 24
25
Manual del Usuario / action series / User’s Manual
Page 3
Precauciones de Seguridad
action series
Cajas acústicas activas / Self-powered loudspeaker enclosures
Safety Precautions
El signo de exclamación dentro de un triángulo indica la existencia de importantes instrucciones de operación y mantenimiento en la documentación que acompaña al producto. Conserve y lea todas estas instrucciones. Siga las advertencias.
ATENCIÓN: Es un producto clase A, por lo que en entornos domésticos puede causar radio-interferencias, en cuyo caso el usuario tendrá que tomar las medidas oportunas. De acuerdo con EN55103-2, usar el equipo sólo en entornos E1, E2, E3 ó E4.
No desconecte la tierra en el conector de alimentación pues es peligroso e ilegal. Equipo de Clase I. El producto debe ser conectado a un enchufe con toma de tierra. Sólo use este equipo con el cable de red de alimentación adecuado para su país. El signo del rayo con la punta de flecha, alerta contra la presencia de voltajes peligrosos no aislados. Para reducir el riesgo de choque eléctrico, no retire la cubierta.
No instale el aparato cerca de ninguna fuente de calor como radiadores, estufas u otros aparatos que produzcan calor. Debe instalarse siempre sin bloquear la libre circulación de aire por las aletas del radiador. Si los altavoces action se utilizan al aire libre en un día soleado, colocar los altavoces en un área sombreada o a cubierto. Los amplificadores de los altavoces tienen circuitos de protección que silenciarán temporalmente el altavoz cuando las temperaturas que se alcanzan sean extremadamente altas. Esto puede suceder en los días calurosos cuando el altavoz esté expuesto a la luz solar directa. No exponga este equipo a la lluvia o humedad. No use este aparato cerca del agua (piscinas y fuentes, por ejemplo). No exponga el equipo a salpicaduras ni coloque sobre él objetos que contengan líquidos, tales como vasos y botellas. Equipo IP-20.
Este símbolo indica que el presente producto no puede ser tratado como residuo doméstico normal, sino que debe entregarse en el correspondiente punto de recogida de equipos eléctricos y electrónicos.
Equipo diseñado para funcionar entre 15ºC y 45ºC con una humedad relativa máxima del 95%, con un rango de ±10% de la tensión nominal de alimentación indicada en la etiqueta trasera (según IEC 60065). Si debe sustituir el fusible preste atención al tipo y rango.
El cableado exterior conectado al equipo requiere de su instalación por una persona instruida o el uso de cables flexibles ya preparados. Si el aparato es conectado permanentemente, la instalación eléctrica del edificio debe incorporar un interruptor multipolar con separación de contacto de al menos 3mm en cada polo. Para desconectar el dispositivo debe usar el enchufe. Desconecte este aparato durante tormentas eléctricas, terremotos o cuando no se vaya a emplear durante largos periodos.
No emplace altavoces en proximidad a equipos sensibles a campos magnéticos, tales como monitores de televisión o material magnético de almacenamiento de datos.
Para las cajas con vaso para trípode, la altura máxima de seguridad desde el suelo a la base de la caja montada sobre trípode modelo TRD-2, con pies a 55 cm del eje del trípode, es:
ACTION-8A -------------->125 cm ACTION-12A ------------->115 cm ACTION-15A ------------->105 cm
El colgado del equipo sólo debe realizarse utilizando los herrajes de colgado recomendados y por personal cualificado. No cuelgue la caja de las asas.
No existen partes ajustables por el usuario en el interior de este equipo. Cualquier operación de mantenimiento o reparación debe ser realizada por personal cualificado. Es necesario el servicio técnico cuando el equipo se haya dañado de alguna forma, como que haya caído líquido o algún objeto en el interior del aparato, haya sido expuesto a lluvia o humedad, no funcione correctamente, haya recibido un golpe o su cable de red esté dañado.
Limpie con un paño seco. No use limpiadores con disolventes. Clean only with a dry cloth. Do not use any solvent based
55 cm
The exclamation point inside an equilateral triangle is intended to alert the users to the presence of important operating and mainten ance (servi cing) instruc tions in the li terature accompanying the product. Heed all warnings. Follow all instructions. Keep these instructions. WARNING: This is a class A product. In a domestic environment this product may cause radio interferences in which case the user may be required to take adequate measures. Use this product only in E1, E2, E3 or E4 environments according to EN55103-2. Do not remove mains connector ground, it is dangerous and illegal. Class I device. The product must be connected to a mains socket outlet with protective earth connection. Only use this equipment with an appropriate mains cord for your country.
The lightning and arrowhead symbol warns about the presence of uninsulated dangerous voltage. To reduce the risk of electric shock, do not remove the cover.
Do not install near any heat sources such as radiators, heat registers, stoves or other apparatus that produce heat. The circulation of air through the heatsink must not be blocked.
If action loudspeakers are used outdoors on a sunny day, place the loudspeakers in a shaded or covered area. The loudspeaker amplifiers have protection circuits that temporarily shut the loudspeaker off when extremely high temperatures are reached. This can happen on hot days when the loudspeaker is in direct sunlight.
Do not expose this device to rain or moisture. Do not use this apparatus near water (for example, swimming pools and fountains). Do not place any objects containing liquids, such as bottles or glasses, on the top of the unit. Do not splash liquids on the unit. IP-20 equipment.
This symbol on the product indicates that this product should not be treated as household waste. Instead it shall be handed over to the appicable collection point for the recycling of electrical and electronic equipment.
Working temperature ranges from 15ºC to 45ºC with a relative humidity of 95%, with ±10% of the rated main voltage value indicated on the rear label (according to IEC 60065). If the fuse needs to be replaced, please pay attention to correct type and ratings.
The outer wiring connected to the device requires installation by an instructed person or the use of a flexible cable already prepared. If the apparatus is connected permanently, the electrical system of the building must incorporate a multipolar switch with a separation of contact of at least 3mm in each pole. To disconnect the device, you should use the mains plug. Unplug this apparatus during lightning storms, earthquakes or when unused for long periods of time.
Do not place loudspeakers in proximity to devices sensitive to magnetic fields such as television monitors or data storage magnetic material.
For enclosures with tripod socket, the maximum safety height from floor to bottom of enclosure when mounting on a TRD-2 tripod, with legs spread 55cm from the central pole, is:
ACTION-8A -------------->125 cm ACTION-12A ------------->115 cm ACTION-15A ------------->105 cm
The appliance should be flown only from the rigging points and by qualified personnel. Do not suspend the box from the handles.
No user serviceable parts inside. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally or has been dropped.
cleaners.
Manual del Usuario / action series / User’s Manual
3
Page 4
GARANTÍA
Todos nuestros productos están garantizados por un periodo de 24 meses desde la fecha de compra.
Las garantías sólo serán válidas si son por un defecto de fabricación y en ningún caso por un uso incorrecto del producto.
Las reparaciones en garantía pueden ser realizadas, exclusivamente, por el fabricante o el servicio de asistencia técnica autorizado.
Otros cargos como portes y seguros, son a cargo del comprador en todos los casos.
Para solicitar reparación en garantía es imprescindible que el producto no haya sido previamente manipulado e incluir una fotocopia de la factura de compra.
WARRANTY
All our products are warrantied against any manufacturing defect for a period of 2 years from date of purchase.
The warranty excludes damage from incorrect use of the product.
All warranty repairs must be exclusively undertaken by the factory or any of its authorised service centers.
To claim a warranty repair, do not open or intend to repair the product.
Return the damaged unit, at shippers risk and freight prepaid, to the nearest service center with a copy of the purchase invoice.
4
Manual del Usuario / action series / User’s Manual
Page 5
DECLARACIÓN DE CONFORMIDAD
DECLARATION OF CONFORMITY
DAS Audio Group, S.L.
C/ Islas Baleares, 24 - 46988 - Pol. Fuente del Jarro - Valencia. España (Spain).
Declara que / ACTION-8A / ACTION-12A / ACTION-M12A / ACTION-15A / ACTION-215A
ACTION-18A / ACTION-118A / ACTION-218A:
Declares that / ACTION-8A / ACTION-12A / ACTION-M12A / ACTION-15A / ACTION-215A
ACTION-18A / ACTION-118A / ACTION-218A:
Cumple con los objetivos esenciales de las Directivas: Abide by essential objectives relating Directives:
l de Baja Tensión (Low Voltage Directive) 2014/35/UE
l de Compatibilidad Electromagnética (EMC) 2014/30/UE
l RoHS 2011/65/UE
l RAEE (WEEE) 2012/19/UE
Y es conforme a las siguientes Normas Armonizadas Europeas: In accordance with Harmonized European Norms:
l EN 60065:2014.- Audio, video and similar electronic apparatus. Safety
requirements.
l EN 55032:2012.- Electromagnetic compatibility of multimedia equipment.
Emission requirements.
l EN 55103-2:2009.- Electromagnetic compatibility. Product family
standard for audio, video, audio-visual and entertainment lighting control apparatus for professional use. Part 2:Immunity.
l EN 50581:2012.- Technical documentation for the assessment of
electrical and electronic products with respect to the restriction of hazardous substances.
Manual del Usuario / action series / User’s Manual
5
Page 6
INTRODUCTION
The action series inherits the exceptional sound quality and rugged build that have made DAS professional systems an internacional sound reinforcement standard. Designed from “real-world” experience, they offer users outstanding performance, absolute reliability, and unparalleled convenience. Whether it is in a high­profile venue or on the stage of a major event, the action series will provide the power and definition needed to make your performance a success.
Settings
ACTION-8A
- Compact multi-purpose system with monitor position
- Ultra lightweight Class D amplifier
- Switch-mode power supply
- Reduces size and weight
- Pole mount socket The ACTION-8A offers a multi-angle enclosure which allows it to be used in stage monitor applications as well as a compact P.A. system. The 720 W peak power of the Class D amplifier provides extended bandwith, improved dynamic range and exceptionally low distortion-features hard to find on other systems in this market segment. The 8B4 loudspeaker provides accurate low frequency reproduction. High frequencies are handled by the M-26 compression driver with 1” exit and titanium diaphragm offering excellent performance.
ACTION-12A
-Two-way powered system.
-12” bass loudspeaker.
-Compressor driver with titanium diaphragm.
-Asimetric encolusure design for stage monitor use.
-Built-in rigging points (eyebolt based).
-Stand mountable. The ACTION-12A is a powered loudspeaker (2 channel Class D amplifier), that utilizes a 12” low frequency transducer and a 1” exit compression driver. The multi-angle cabinet is constructed of Birch plywood protected by an environmentally friendly black paint finish. Two bar handles and a steel grille are provided. A 35mm tripod socket allows for stand mounting.
ACTION-15A
-Two-way powered system
-15” bass loudspeaker
-Compression driver with titanium diaphragm
-Asymmetric enclosure design for stage monitor use
-Built-in rigging points (eyebolt bassed)
-Stand mountable ACTION-15A is a powered loudspeaker (2 channel Class D amplifier), uses a 15” low frequency transducer and a 1” exit compression driver with titanium diaphragm. The cabinet is constructed from Birch plywood and finished with an envinonmentally friendly black paint finish. Two bar handles are provided and a steel grille protects components. A 35mm tripod socket allows for stand mounting. Rigging points provide a safe and simple solution for suspending the ACTION-15A
ACTION-M12A
-Dedicated powered stage monitor.
-12” bass loudspeaker.
-Compression driver with titanium diaphragm.
-Low profile enclosure design for minimum visual impact.
-Black paint finish.
-Stand mountable. The ACTION-M12A is a dedicated powered stage monitor (2channel Class D amplifier). The enclosure ir constructed from Birch plywood and is protected with a black paint finish. Two side located handles facilitate handling and a steel grille protects the components. A pole mount socket adds versatility to the ACTION- M12A.
6
Manual del Usuario / action series / User’s Manual
Page 7
ACTION-215A
- 2-way powered system
- 2 x 15" bass loudspeaker
- Compression driver with titanium diaphragm
- Two steel-reinforced handles The ACTION-215A is a powered loudspeaker (2 channel Class D amplifier), that utilizes two 15” bass loudspeakers for extra low frequency punch and higher SPL. High frequencies are handled by a 1” compression driver with titanium diaphragm. The trapezoidal cabinet is constructed using Birch plywood and protected with a hard-wearing black paint finish. Two bar handles and a steel grille sealed against corrosion using a polyamide powder coat finish are provided. Rigging points provide a safe and simple way to fly the ACTION-215A cabinets.
ACTION-18A
- Bass-reflex powered subwoofer system
- 18" low frequency transducer
- Precise and powerful bass reproduction
- Top located pole mount socket The ACTION-18A bass powered system (Class D amplifier) incorporates a 18” low frequency transducer with a 4" voice coil mounted as a direct radiator into a bass-reflex cabinet. The loudspeaker is protected by a perforated steel grille, sealed against corrosion using a powder coat finish. The ACTION-18A is designed for use in biamped systems. A top located pole­mount socket permits mounting full-range systems above the
ACTION-18A and two bar handles makes moving easy.
ACTION-118A
- Powered horn-bass subwoofer system
- Class D 3200W amplifier
- 1x D.A.S. 18" long excursion woofer
- Deep/Loud EQ selector
- Filtered output defeat switch
- Variable 80-125 Hz high-pass filter
- Gain control and polarity switch
- Top located pole mount socket The ACTION-118A horn bass powered system (Class D amplifier) incorporates a 18” long excursion woofer with a 4" voice coil mounted as a direct radiator with load cabinet. The loudspeaker is protected by a perforated steel grille, sealed against corrosion using a powder coat finish. The ACTION-118A is designed for use in biamped systems. A top located pole­mount socket permits mounting full-range systems above the
ACTION-118A and two bar handles makes moving easy.
ACTION-218A
- High output bass-reflex powered subwoofer system
- Twin 18" loudspeakers
- Durable black paint finish
- Side located bar handles This bass-reflex powered subwoofer system uses dual 18" bass loudspeakers equipped with 4" voice coils. The exceptional power handling capacity and efficiency provide high sound pressure levels of powerful bass. Two hand locations facilitate handling. The cabinet is designed to be stacked in the vertical position in order to reduce the units "on-stage" footprint.
Manual del Usuario / action series / User’s Manual
7
Page 8
CONFIGURATIONS
ACTION-8A
TRD-6
ACTION-8A
TRD-6
DSP-26
L
INPUTS
AB
R
Mixer
8
Manual del Usuario / action series / User’s Manual
Page 9
CONFIGURATIONS (cont´d)
ACTION-18A
LOW-PASS
SUB LEVEL
CROSSOVER
100Hz
180º
CAUTION
risk of electric shock
do not open
CAUTION
HOT SURFACE,
AVOID CONTACT
PHASE
LIMIT
ATTENTION
danger d’electrocution
ATTENTION
TEMPERATURE ELEVEE!
NE PAS TOUCHER!
MIN 60HzMAX 160Hz
WARNING: TO REDUC E RISK OF F IRE OR ELE CTRIC SHO CK DO NOT E XPOSE THI S EQUIPMENT TO RA IN OR MOIS TURE WARNING: THIS PRO DUCT MUST B E GROUNDE D REFER TO INSTRU CTIONS MA NUAL FOR CO NNECTION NO USER SERVICE ABLE PARTS I NSIDE
ATENCIÓN: PARA REDUCI R EL RIESGO D E FUEGO O D ESCARGAS E LÉCTRIC AS NO EXPONGA ESTE EQU IPO A LA LLUVIA NI A LA HUME DAD ATENCIÓN: ESTE APARATO DE BE CONECTAR SE A TIERRA VEASE MANUAL DE I NSTRUCC IONES PARA LA CO NEXIÓN NO EXISTEN PARTES A JUSTABLES P OR EL USUAR IO EN EL INT ERIOR DEL EQ UIPO
INPUT
SIGNAL
SIGNAL
ON
INPUT A INPUT B OUTPUT A OUTPUT B
ne pas ouvrir
HPF
THRU
action 18A
Class D Power Amplifier
POWER
115/230V 50/60HZ 800W T5AL 250V FOR 230V INPUT T9AL 250V FOR 115V INPUT
SATELLITE
OUTPUT
22000001
ACTION-8A
TRD-2
DSP-26
Mixer
ACTION-8A
INPUTS
AB
TRD-2
L
R
Manual del Usuario / action series / User’s Manual
9
Page 10
CONFIGURATIONS (cont´d)
ACTION-8A
TRD-6
ACTION-18A
DSP-26
ACTION-8A
TRD-6
INPUTS
AB
ACTION-18A
LOW-PASS
SUB LEVEL
CROSSOVER
100Hz
MIN 60HzMAX 160Hz
risk of electric shock
WARNING: TO REDUC E RISK OF F IRE OR ELE CTRIC SHO CK DO NOT E XPOSE THI S EQUIPMENT TO RA IN OR MOIS TURE WARNING: THIS PRO DUCT MUST B E GROUNDE D REFER TO INSTRU CTIONS MA NUAL FOR CO NNECTION NO USER SERVICE ABLE PARTS I NSIDE
ATENCIÓN: PARA REDUCI R EL RIESGO D E FUEGO O D ESCARGAS E LÉCTRIC AS NO EXPONGA ESTE EQU IPO A LA LLUVIA NI A LA HUME DAD ATENCIÓN: ESTE APARATO DE BE CONECTAR SE A TIERRA VEASE MANUAL DE I NSTRUCC IONES PARA LA CO NEXIÓN NO EXISTEN PARTES A JUSTABLES P OR EL USUAR IO EN EL INTE RIOR DEL EQ UIPO
10
CAUTION
do not open
CAUTION
HOT SURFACE,
AVOID CONTACT
INPUT
SIGNAL
180º
LIMIT
SIGNAL
ON
INPUT A INPUT B OUTPUT A OUTPUT B
PHASE
ATTENTION
danger d’electrocution
ne pas ouvrir
ATTENTION
TEMPERATURE ELEVEE!
NE PAS TOUCHER!
HPF
THRU
action 18A
Class D Power Amplifier
POWER
Mixer
SATELLITE
OUTPUT
22000001
115/230V 50/60HZ 800W T5AL 250V FOR 230V INPUT T9AL 250V FOR 115V INPUT
Manual del Usuario / action series / User’s Manual
L
R
Page 11
CONFIGURATIONS (cont´d)
ACTION-15A (or ACTION-12A)
TRD-2
ACTION-15A (or ACTION-12A)
TRD-2
DSP-26
L
INPUTS
R
Mixer
Manual del Usuario / action series / User’s Manual
AB
11
Page 12
CONFIGURATIONS (cont’d)
ACTION-18A
LOW-PASS
SUB LEVEL
CROSSOVER
100Hz
180º
CAUTION
risk of electric shock
do not open
CAUTION
HOT SURFACE,
AVOID CONTACT
PHASE
LIMIT
ATTENTION
danger d’electrocution
ATTENTION
TEMPERATURE ELEVEE!
NE PAS TOUCHER!
MIN 60HzMAX 160Hz
WARNING: TO REDUC E RISK OF F IRE OR ELE CTRIC SHO CK DO NOT E XPOSE THI S EQUIPMENT TO RA IN OR MOIS TURE WARNING: THIS PRO DUCT MUST B E GROUNDE D REFER TO INSTRU CTIONS MA NUAL FOR CO NNECTION NO USER SERVICE ABLE PARTS I NSIDE
ATENCIÓN: PARA REDUCI R EL RIESGO D E FUEGO O D ESCARGAS E LÉCTRIC AS NO EXPONGA ESTE EQU IPO A LA LLUVIA NI A LA HUME DAD ATENCIÓN: ESTE APARATO DE BE CONECTAR SE A TIERRA VEASE MANUAL DE I NSTRUCC IONES PARA LA CO NEXIÓN NO EXISTEN PARTES A JUSTABLES P OR EL USUAR IO EN EL INTE RIOR DEL EQ UIPO
INPUT
SIGNAL
SIGNAL
ON
INPUT A INPUT B OUTPUT A OUTPUT B
ne pas ouvrir
HPF
THRU
action 18A
Class D Power Amplifier
POWER
115/230V 50/60HZ 800W T5AL 250V FOR 230V INPUT T9AL 250V FOR 115V INPUT
SATELLITE
OUTPUT
22000001
ACTION-15A (or ACTION-12A)
TRD-2
DSP-26
Mixer
ACTION-15A (or ACTION-12A)
INPUTS
AB
TRD-2
L
R
12
Manual del Usuario / action series / User’s Manual
Page 13
CONFIGURATIONS (cont’d)
TRD-6
ACTION-15A (or ACTION-12A)
ACTION-18A
LOW-PASS
SUB LEVEL
CROSSOVER
100Hz
180º
MIN 60HzMAX 160Hz
PHASE
INPUT
SIGNAL
LIMIT
SIGNAL
ON
INPUT A INPUT B OUTPUT A OUTPUT B
THRU
ACTION-15A (or ACTION-12A)
TRD-6
DSP-26
INPUTS
AB
ACTION-18A
L
SATELLITE
OUTPUT
HPF
Mixer
R
ATTENTION
CAUTION
risk of electric shock
danger d’electrocution
do not open
ne pas ouvrir
ATTENTION
CAUTION
HOT SURFACE,
TEMPERATURE ELEVEE!
AVOID CONTACT
WARNING: TO REDUC E RISK OF F IRE OR ELE CTRIC SHO CK DO NOT E XPOSE THI S EQUIPMENT TO RA IN OR MOIS TURE WARNING: THIS PRO DUCT MUST B E GROUNDE D REFER TO INSTRU CTIONS MA NUAL FOR CO NNECTION NO USER SERVICE ABLE PARTS I NSIDE
ATENCIÓN: PARA REDUCI R EL RIESGO D E FUEGO O D ESCARGAS E LÉCTRIC AS NO EXPONGA ESTE EQU IPO A LA LLUVIA NI A LA HUME DAD ATENCIÓN: ESTE APARATO DE BE CONECTAR SE A TIERRA VEASE MANUAL DE I NSTRUCC IONES PARA LA CO NEXIÓN NO EXISTEN PARTES A JUSTABLES P OR EL USUAR IO EN EL INTE RIOR DEL EQ UIPO
NE PAS TOUCHER!
22000001
action 18A
Class D Power Amplifier
115/230V 50/60HZ 800W T5AL 250V FOR 230V INPUT
POWER
T9AL 250V FOR 115V INPUT
Manual del Usuario / action series / User’s Manual
13
Page 14
CONFIGURATIONS (cont’d)
TRD-6
ACTION-218A
ACTION-15A (or ACTION-12A)
DSP-26
Mixer
ACTION-15A (or ACTION-12A)
INPUTS
AB
L
R
ACTION-218A
TRD-6
14
Manual del Usuario / action series / User’s Manual
Page 15
CONFIGURATIONS (cont’d)
ACTION-215A
DSP-26
Mixer
ACTION-215A
INPUTS
AB
L
R
Manual del Usuario / action series / User’s Manual
15
Page 16
CONFIGURATIONS (cont’d)
ACTION-M12A
ACTION-M12A
ACTION-M12A
ACTION-M12A
16
DSP-26
Mixer
INPUTS
AB
L
Manual del Usuario / action series / User’s Manual
R
Page 17
LINE DRAWINGS
ALL DIMENSIONS IN MILLIMETERS
14
ACTION-8A
ACTION-M12AACTION-15AACTION-215AACTION-18A ACTION-12A
316
Top View
Bottom View
255
653
279
Front View
645
Front View
378
Right View
420
Right View
475
Rear View
Rear View
324
Bottom View
436
Bottom View
474
Bottom View
446
Front View
447
Front View
540
774
Right View
Right View
Right ViewFront View
Rear View
Rear View
1154
Rear View
650
Top View Right View
Front View
Manual del Usuario / action series / User’s Manual
624
INPUT
LOW-PASS
SUB LEVEL
SIGNAL
CROSSOVER
100Hz
180º
LIMIT
SIGNAL
ON
MIN 60HzMAX 160Hz
INPUT A INPUT B OUTPUT A OUTPUT B
PHASE
ATTENTION
CAUTION
risk of electric shock
danger d’electrocution
do not open
ne pas ouvrir
ATTENTION
CAUTION
HOT SURFACE,
TEMPERATURE ELEVEE!
AVOID CONTACT
NE PAS TOUCHER!
WARNING: TO REDUCE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE WARNING: THIS PRODUCT MUST BE GROUNDED REFER TO INSTRUCTIONS MANUAL FOR CONNECTION NO USER SERVICEABLE PARTS INSIDE
ATENCIÓN: PARA REDUCIR EL RIESGO DE FUEGO O DESCARGAS ELÉCTRICAS NO EXPONGA ESTE EQUIPO A LA LLUVIA NI A LA HUMEDAD ATENCIÓN: ESTE APARATO DEBE CONECTARSE A TIERRA VEASE MANUAL DE INSTRUCCIONES PARA LA CONEXIÓN NO EXISTEN PARTES AJUSTABLES POR EL USUARIO EN EL INTERIOR DEL EQUIPO
N1918
D.A.S. AUDIO S.A. (Valencia) SPAIN
Rear View
SATELLITE
OUTPUT
HPF THRU
115/230V 50/60HZ 800W T5AL 250V FOR 230V INPUT
POWER
T9AL 250V FOR 115V INPUT
17
Page 18
ALL DIMENSIONS IN MILL IMETRES
690
ACTION-118A
ACTION-218A
Top View
Top View
SPECIFICATIONS
ACTION-8A
Model
Power Amplifier
Input Impedance
Frequency Range (-10 dB)
HF Horn Coverage Angles (-6 dB)
Maximum Peak SPL at 1m
Transducers/ Replacement Parts
Enclosure Material
Color/Finish
Connectors
AC Power Requeriments
Dimensions (H x W x D)
Accessories
720 W peak 360 W continuous (Class D Bi-amplified)
Input Type
Balanced Differential Line Line: 20 kohms
Sensitivity
Line: 1.95V (+8dBu) 60 Hz - 20 kHz 80º x 80º (Rotatable) 120 dB LF: 1 x 8B4/ 8B4 HF: 1 x M-26/GM-M26 Birch Plywood Black Paint INPUT: Female XLR-Jack LOOP THRU: Male XLR AC INPUT: PowerCon NAC 3 FCA 115V, 1.2A, 50 Hz / 60 Hz 230 V, 0.6 A, 50 Hz / 60 Hz
47.5 x 27.9 x 25.5 cm
18.7 x 11 x 10 in
9.9 kg (21.8 lb)
Weight
AXW-1 AXU-ACT8 TRD-2 TRD-6
670
566
Front View
540
Front View
ACTION-M12A
1000 W peak 500 W continuous (Class D Bi-amplified) Balanced Differential Line Line: 20 kohms Line: 1.95V (+8dBu) 60 Hz - 20 kHz 80º x 50º 130 dB LF: 12MI / GM-12MI HF: M-34 / GM-M34 Birch Plywood Black Paint INPUT: Female XLR LOOP THRU: Male XLR AC INPUT: PowerCon NAC 3 FCA 115V, 2.4A, 50 Hz / 60 Hz 230V, 1.2A, 50 Hz / 60 Hz 42 x 64.5 x 31.6 cm
16.6 x 25.4 x 12.5 in 19 kg (41.8 lb) TRD-2 TRD-6
791
Right View
1067
Right View
ACTION-12A
1000 W peak 500 W continuous (Class D Bi-amplified) Balanced Differential Line Line: 20 kohms Line: 1.95V (+8dBu) 50 Hz - 20 kHz 80º x 50º 131 dB LF: 12MI / GM-12MI HF: M-34 / GM-M34 Birch Plywood Black Paint INPUT: Female XLR LOOP THRU: Male XLR AC INPUT: PowerCon NAC 3 FCA 115V, 2.4A, 50 Hz / 60 Hz 230V, 1.2A, 50 Hz / 60 Hz
65.3 x 37.8 x 32.4 cm
25.7 x 14.9 x 12.8 in 20 kg (44 lb) ANL-2 TRD-2 TRD-6
Rear View
Rear View
ACTION-15A
1000 W peak 500 W continuous (Class D Bi-amplified) Balanced Differential Line Line: 20 kohms Line: 1.95V (+8dBu) 45 Hz - 20 kHz 80º x 50º 131 dB LF: 15MI / GM-15MI HF: M-34 / GM-M34 Birch Plywood Black Paint INPUT: Female XLR LOOP THRU: Male XLR
AC INPUT: PowerCon NAC 3 FCA 115V, 3A, 50 Hz / 60 Hz 230V, 1.5A, 50 Hz / 60 Hz
77.4 x 44.6 x 43.64 cm
30.5 x 17.6 x 17.2 in 26 kg (57.2 lb) ANL-2 TRD-2 TRD-6
ACTION-215A
Model
Power Amplifier
Input Type
Input Impedance
Sensitivity
Frequency Range (-10 dB)
HF Horn Coverage Angles (-6 dB)
Maximum Peak SPL at 1m
Transducers/ Replacement Parts
Enclosure Material
Color/Finish
Connectors
AC Power Requirements
Dimensions (H x W x D)
Accessories
1000 W peak 500 W continuous (Class D Bi-amplified) Balanced Differential Line Line: 20 kohms Line: 1.95V (+8dBu) 45 Hz - 20 kHz 80º x 50º 134 dB LF: 2x 15M I4 / GM-15M I4 HF: M-44 / GM-M44 Birch Plywood Black Paint INPUT: Female XLR LOOP THRU: Male XLR AC INPUT: PowerCon NAC 3 FCA
115V, 3.6A, 50 Hz / 60 Hz 230V, 1.8A, 50 Hz / 60 Hz
115.4 x 44.7 x 47.4 cm
45.5 x 17.6 x 18.7 in 44 kg (88 lb)
Weight
ANL-2
ACTION-18A
1500 W peak 750 W continuous (Class D) Balanced Differential Line Line: 20 kohms Line: 1.95V (+8dBu) 35 Hz - 160 Hz
- - ­133 dB LF: 18H / GM-18G
Birch Plywood Black Paint INPUT: 2x Female XLR LOOP THRU: 2x Male XLR AC INPUT: Male IEC
115V, 3A, 50 Hz / 60 Hz 230V, 1.5A, 50 Hz / 60 Hz
62.4 x 54 x 65 cm
24.6 x 21.3 x 25.6 in
36.5 kg (80.3 lb) TRD-6
ACTION-118A
3200 W peak 1600 W continuous (Class D) Balanced Differential Line Line: 20 kohms Line: 1.95V (+8dBu) 50 Hz - 160 Hz
- ­137 dB LF: 1x 18L X / GM-18L X
Birch Plywood Black Paint INPUT: 2x Female XLR LOOP THRU: 2x Male XLR AC INPUT: PowerCon NAC 3 FCA AC OUTPUT: PowerCon NAC 3 FCB 115V, 5.4A, 50 Hz / 60 Hz 230V, 2.7A, 50 Hz / 60 Hz
79.1 x 69 x 56.7 cm
31.14 x 27.17 x 22.32 in 55 kg (121 lb) TRD-6
ACTION-218A
3200 W peak 1600 W continuous (Class D) Balanced Differential Line Line: 20 kohms Line: 1.95V (+8dBu) 35 Hz - 160 Hz
- ­140 dB LF: 2x 18H4 / GM-18G4
Birch Plywood Black Paint INPUT: 2x Female XLR LOOP THRU: 2x Male XLR AC INPUT: PowerCon NAC 3 FCA AC OUTPUT: PowerCon NAC 3 FCB 115V, 5.4A, 50 Hz / 60 Hz 230V, 2.7A, 50 Hz / 60 Hz
106.7 x 54 x 67 cm 42 x 21.3 x 26.4 in 63 kg (138.6 lb) TRD-6
DAS Audio Group, S.L., continuously strives to enhance its products through investigation and development. All specifications are subject to change without prior notice.
18
Manual del Usuario / action series / User’s Manual
Page 19
AMPLIFIER
Description
1) INPUT : 1/4” Jack+XLR combined socket-type input signal
connector. This is a balanced connector just like the LOOP THRU connector with the following pin assignments:
1 or S =GND (ground). 2 or T =(+) Non inverted input. 3 or R =(-) Inverted input.
2) LOOP THRU (except SUBs): XLR-type output signal connector for connecting several units together and sending them all the same signal.
2) SATELLITE OUTPUT (only SUBs): A and B, XLR-type output signal connectors for connecting several units together and sending them all the same input signal or filtered signal (by using THRU/HPF).
1
ACTION-8A amplifier
3) LIMIT : Red LED indicates amplifier saturation. Amplifier limiter indicator lights.
4) SIGNAL : Green LED indicates signal presence.
5) ON : Green LED (blue for ACTION-18A) indicates that the unit is ON.
6) LEVEL / SUB LEVEL : Potentiometer for adjusting the unit level.
7) MAIN / MONITOR (only ACTION-M12A) / BOOST / FLAT : Button for switching between two types of frequency response. Press the button to use the unit without subwoofer. Please note that the unit will therefore reach its limits sooner.
8) MIC / LINE : Button for switching between microphone and line sensitivities. NEVER PRESS THIS BUTTON WITHOUT
FIRST REDUCING THE LEVEL OF THE UNIT TO AVOID EXTREMELY HIGH SPL.
9) LOGO OFF / ON :
Press the button to illuminate the logo.
10) AC INPUT : Standard IEC-60320 (only ACTION-18A) or PowerCon NAC3FCA mains connector (inserted, rotated and locked for ON). Only use this equipment
with an appropriate mains cord.
11) POWER :
Mains power ON/OFF switch.
12) THRU/HPF : ‘SATELLITE OUTPUT’ selector to switch between full range signal or pass filter with cut-off frequency of 100 Hz.
13) LINE SELECT (only ACTION-18A) : Mains voltage selector (115V AC or 230V AC). Before operating, verify
the voltage selection.
14) LOW-PASS CROSSOVER :
Button for adjusting the upper cut-off frequency for the subwoofer unit (see label). We recommend a cut-off frequency of 100 Hz.
15) PHASE : Switch for inverting the phase of the unit.
16) FUSE (only ACTION-18A) : Fuse holder. Only use the recommended fuse type and size.
17) PRESET DEEP/LOUD (only ACTION-118A and ACTION-218A) : Button for switching between two types of frequency response, DEEP or LOUD.
18) AC OUTPUT (only ACTION-118A and ACTION-218A) : PowerCon NAC3FCB connector for AC loop thru allows up to 6 units when
using a 230V version (see unit’s label)). Only use this equipment with an
appropriate mains cord.
19) Fan (only ACTION-118A and ACTION-218A).
6
2
LOW-PASS
SUB LEVEL
CROSSOVER
100Hz
MIN 60HzMAX 160Hz
15
14
6
risk of electric shock
WARNING: TO REDU CE RISK OF F IRE OR EL ECTRIC SH OCK DO NOT E XPOSE TH IS EQUIPMENT TO R AIN OR MOI STURE WARNING: THIS PR ODUCT MUS T BE GROUND ED REFER TO INSTR UCTIONS M ANUAL FOR C ONNECTIO N NO USER SERVIC EABLE PARTS I NSIDE
ATENCIÓN: PARA REDUC IR EL RIESG O DE FUEGO O D ESCARGA S ELÉCTRI CAS NO EXPONGA ESTE EQ UIPO A LA LLUVIA NI A LA HUM EDAD ATENCIÓN: ESTE APARATO D EBE CONEC TARSE A TIERRA VEASE MANUAL D E INSTRUC CIONES PARA LA C ONEXIÓN NO EXISTEN PARTE S AJUSTABLES P OR EL USUAR IO EN EL INT ERIOR DE L EQUIPO
11
10
8
7
3
1
4
9
5
ACTION-M12A, ACTION-12A, ACTION-15A & ACTION-215A
amplifiers
CAUTION
do not open
CAUTION
HOT SURFACE, AVOID CONTACT
INPUT
SIGNAL
180º
LIMIT
SIGNAL
ON
INPUT A INPUT B OUTPUT A OUTPUT B
PHASE
1
5
3
4
ATTENTION
danger d’electrocution
ne pas ouvrir
ATTENTION
TEMPERATURE ELEVEE!
NE PAS TOUCHER!
11
12
THRU
POWER
SATELLITE
OUTPUT
HPF
2
13
115/230V 50/60HZ 800W T5AL 250V FOR 230V INPUT T9AL 250V FOR 115V INPUT
ACTION-18A amplifier
19
3
5
6
15
4
14
17
2
9
12
1
10
16
18
ACTION-118A and ACTION-218A
amplifier
7
6
8
3
9
2
10
10
4
5
11
16
Manual del Usuario / action series / User’s Manual
19
Page 20
ON / OFF
A sound system should be switched on sequentially. Switch on the self-powered units last in your sound system (switch on the subwoofer before the mid-high system). Switch on the sound sources such as CD players or turntables, then the mixer, then the processors, and finally the self­powered unit. If you have several units, it is recommended that you switch them on sequentially one at a time. Follow the inverse order when switching off, turning self-powered units off before any other element in the sound system.
Disconnect the device by removing the mains connector from the mains socket. The mains connector and mains socket must always be freely accessible and never covered or blocked in any way. The mains cable can be detached from the device by disconnecting the standard IEC-60320 connector (only ACTION-18A). Always disconnect the device by removing the mains connector from the mains socket before detaching the mains cable at the standard IEC-60320 connector (only ACTION-18A). The rest of models use a power cable equipped with a Neutrik PowerCon NC3FCA connector. Power can be daisy chained via the NC3FCB output connector (see details on product label).
Normally it is enough just to let the unit cool down after you have corrected the problem so that the system functions properly again. ACTION-118A and ACTION-218A amplifiers are equipped with fan and heatsink to maintain the correct operating temperature. Keep grilles clean and dust-free. Do not block or obstruct in any way the air entrance or exit while the equipment is in use. Air circulates from the bottom to the top of the amplifier.
Heatsink
Exit of air
IMPORTANT: Do not disconnect the unit while in use. Ensure that the device is disconnected from the mains by observing that the ON LED is turned off. Please note that the ON LED can stay on for several seconds after the mains power has been disconnected.
Overload indicator
This device has an indicator (LIMIT LED) that lights when the signal is excessive. The indicator should not be lit continuously. This distorts the signal (quickly fatiguing your ears) and may damage the speakers. Therefore, it is recommended that you never work with this LED on; at most it should blink only occasionally.
Equalisation
The unit does not need extreme settings of equalisation to produce quality sound. Avoid high levels of gain on the equalisers. Gain values above +3 dB on a console’s EQ are not recommended.
Overheating
This equipment does not normally overheat during normal conditions of use. When overheating occurs, the unit protects itself. You should then find out why and if necessary contact an authorised dealer for technical assistance.
Entrance of air
Low mains voltage
If mains voltage falls below the shutdown voltage for the unit, it will stop playing. When acceptable levels are regained, the unit will switch back on automatically.
Therefore the current consumed by a 115V version is double the 230V version to achieve the same acoustic power level.
Pink Noise
Mains 230 Vrms
ACTION-8A
ACTION-12A
ACTION-M12A
ACTION-15A
ACTION-215A
ACTION-18A
ACTION-118A
ACTION-218A
1/3 Potencia
0.6A
1.2A
1.2A
1.5A
1.8A
1.5A
2.7A
2.7A
20
Manual del Usuario / action series / User’s Manual
Page 21
Troubleshooting
PROBLEM
CAUSE
SOLUTION
No sound from the unit. The SIGNAL LED does not light up.
Full power cannot be obtained. The LIMIT LED never lights up.
Sound is distorted. The LIMIT LED is not on, or only lights up occasionally.
Sound is distorted and very loud and LIMIT LED lights up.
Hum or buzz when a mixer is connected to the unit.
Hum or buzz when using lighting controls in the same building.
The ON LED does not light up when the mains connector is connected and the unit is switched to ON.
1 – The signal source is sending no signal. 2 – Defective cable.
3 - The amplifier has overheated.
The signal source does not have a hot enough output.
The mixer or signal source is distorting.
The system is overloaded and has reached maximum power.
1.– The console probably has un­balanced outputs. You may be using an i ncor re c t un-b ala nced t o balanced cable.
2.– The mixer and the powered speaker are not plugged into the same mains outlet.
3.– The audio signal cable is too long or too close to an AC cable
1.– The audio signal cable is too long or too close to the lighting cable.
2.– On a sound system with three­phase AC, the lighting equipment and the UNIT are connected to the same phase.
1.– Bad or loose AC connection to the UNIT or the mains outlet. 2 – Faulty AC cable.
3 – Blown Fuse.
4 - The mains voltage is out of range.
1 – Check that the mixer or sound source is sending signal to the UNIT. 2 – Check that the cable from the sound source to the UNIT is connected correctly. Replace the cable if defective. 3 - Allow the unit to cool down for some minutes and it will function again. Check the main output level of the mixer or channel gains since the unit will have been functioning with excessive levels.
If using a mixer, use the balanced ou t p u t i f a v a i l a b l e . Use a professional mixer with a hotter output.
Turn mixer channel gains down. Check that none of your signal sources are distorting.
Turn down the mixer's output.
1.– Read the appendix of this manual to make a correct un­balanced to balanced cable.
2.– Connect the mixer and the unit to the same mains outlet.
3.– Use a cable that is as short as possible and/or move the audio signal cable away from mains cables.
1.– Move the audio signal cable away from lighting cables. Try to find out at what point the noise is leaking into the system.
2.– Connect the sound system to a different phase than the lights. You may need the help of an electrician.
1.– Check your connections.
2.– Check the cables, connectors and AC power with a suitable mains tester.
3.- Replace the blown fuse for another of the same type and size.
4.- If the multimeter determines that the mains voltage is out the range, you may need the assistance of an electrician to find an appropriate solution.
Manual del Usuario / action series / User’s Manual
21
Page 22
RIGGING
Warnings
This manual contains needed information for flying DAS Audio line array systems, description of the elements and safety precautions. To perform any operations related to flying the system, read the present document first, and act on the warnings and advice given. The goal is to allow the user to become familiar with the mechanical elements required to fly the acoustic system, as well as the safety measures to be taken during set-up and teardown.
Absolutely no risks should be taken with regards to public safety. When flying enclosures from ceiling support structures, extreme care should be taken to assure the load bearing capabilities of the structures so that the installation is absolutely safe. Do not fly enclosures from unsafe structures. Consult a certified professional if needed. All flying accessories that are not supplied by DAS Audio are the user's responsibility. Use at your own risk.
Only experienced installers with adequate knowledge of the equipment and local safety regulations should fly speaker boxes. It is the user's responsibility to ensure that the systems to be flown (including flying accessories) comply with state and local regulations.
The working load limits in this manual are the results of tests by independent laboratories. It is the user's responsibility to stay within safe limits. It is the user's responsibility to follow and comply with safety factors, resistance values, periodical supervisions and warnings given in this manual. Product improvement by means of research and development is on going at DAS. Specifications are subject to change without notice.
It is common practice to apply 5:1 safety factors for enclosures and static elements. For slings and elements exposed to material fatigue due to friction and load variation the following ratios must be met; 5:1 for steel cable slings, 4:1 for steel chain slings and 7:1 polyester slings. Thus, an element with a breaking load limit of 1000 kg may be statically loaded with 200 kg (5:1 safety factor) and dynamically loaded with 142 kg (7:1 safety factor).
Introduction
Flyable action series models feature 6 internal steel angles, with 2 mounting threads each, so that 12 flying points are available (2 on each side, 3 on the top panel and 3 on the bottom panel and 2 on the rear panel). Eyebolt flying points are factory sealed with M10 screws, which are replaced with eyebolts on the flying points as required. Flying with eyebolts is very economical and safe, and is specially recommended for fixed installations where the boxes are permanently fixed.
The illustration shows the internal metal hardware of an enclosure with eyebolt flying.
When flying a system, the working load must be lower than the resistance of each individual flying point in the enclosure, as well as each box. Hanging hardware should be regularly inspected and suspect units replaced if in doubt. This is important to avoid injury and absolutely no risks should be taken in this respect. It is highly recommended that you implement an inspection and maintenance program on flying elements, including reports to be filled out by the personnel that will carry out the inspections. Local regulations may exist that, in case of accident, may require you to present evidence of inspection reports and corrective actions after defects were found.
22
Manual del Usuario / action series / User’s Manual
Page 23
Flying with eyebolts
The Allen-head screws must be removed and replaced by M10 eyebolts on one side of the enclosure. Each rigging point has 200 kg (440 lb) working load limit. Then choose the slings or chains of required load resistance and length, bearing in mind that the length difference between the front and back slings or chains will determine the vertical orientation. Alternatively, the back bottom eyebolt points can be used to provide vertical orientation.
The ANL-2 set is an optional set of four eyebolts and four carabiners. (Dimensions are in milimetres).
ANL-2
The following illustrations show different views on eyebolt flying for a single box. The length of the back cables or chains determines the vertical angle of the box.
Each ANL-2 eyebolt has a rated working load of 200 kg. (440 lb). Each ANL-2 carabiner has a working load of 330 kg (726 lb). If using other hardware, make sure it is rated to handle the required load.
When using eyebolts it is important to bear in mind that the rated working load is only true for a load applied in the plane of the eye, and is significantly reduced for other angles. The drawing illustrates the concept. The table shows the variation of the working load as a function of the load angle. In the case of the ANL-2 eyebolt, this means that the 200 kg working load becomes 60 kg at 45 degrees. Do not use eyebolt flying if the load angle is higher than 45 degrees.
% Working
load
0 Degrees
100% 65% 30% 25%
30 Degrees 45 Degrees More than 45
Degrees
Manual del Usuario / action series / User’s Manual
23
Page 24
Mounting AXU-ACT8 (only for ACTION-8A enclosures)
Introduction
The AXU-ACT8 are designed for enclosures ACTION-8, ACTION-8A-230 and ACTION-8A-115.
Safety Precautions
Wall plugs provided are to be used in brick walls only. For other wall materials, source the suitable wall plug before use.
DAS Audio is not responsible for use other than the
recommended or whether it be the result of insufficient strength of the support structure. Use only the screws and wall plugs supplied on surfaces that will provide sufficient support. Do not use on surfaces such as plaster, and gypsum. It is highly recommended and in most parts of the world mandatory, that a safety cable be used to secure the enclosure to the structure. To ensure optimum safety, the installation should be checked thoroughly at regular intervals replacing all deteriorated elements. Loosen the screws before reorienting the speaker. Never force the rigging elements. Contact a licensed rigger if there is any doubt.
Mounting instructions
You can consult the AXU-ACT8 mounting instructions for ACTION-8A on the web: www.dasaudio.com
24
Manual del Usuario / action series / User’s Manual
Page 25
ANNEX: Line connections: unbalanced and balanced
There are two basic ways to transport an audio signal with microphone or line level:
Unbalanced line: Utilising a two conductor cable, it transports the signal as the voltage between them. Electromagnetic interference can get added to the signal as undesired noise. Connectors that carry unbalanced signals have two pins, such as RCA (Phono) and ¼” (6.35mm, often referred to as jack) mono. 3 pin connector such as XLR (Cannon) may also carry unbalanced signals if one of the pins is unused.
Balanced line: Utilising a three conductor cable, one of them acts as a shield against electromagnetic noise and is the ground conductor. The other two have the same voltage with respect to the ground conductor but with opposite signs. The noise that cannot be rejected by the shield affects both signal conductors in the same way. At the device’s input the two signals get summed with opposite sign, so that noise is cancelled out while the programme signal doubles in level. Most professional audio devices use balanced inputs and outputs. Connectors that can carry balanced signal have three pins, such as XLR (Cannon) and ¼” (6.35mm) stereo.
The graphs that follow show the recommended connection with different types of connectors to balanced processor or amplifier inputs. The connectors on the left-hand side come from a signal source, and the ones on the right hand side go to the inputs of the processor or amplifier. Note that on the unbalanced connectors on the left-hand side, two terminals are joined inside the connector. If hum occurs with balanced to balanced connections, try disconnecting the sleeve (ground) on the input connector. Note that the illustrations show what should be connected to what, but that pin locations on an actual XLR connector are different. Also, pin 2 hot is assumed on XLR connectors.
Manual del Usuario / action series / User’s Manual
25
Page 26
www.dasaudio.com
UM_ACT1_01_EN
DAS Audio Group, S.L.
C/. Islas Baleares, 24 46988 Fuente del Jarro Valencia, SPAIN Tel. +34 96 134 0860
DAS Audio of America, INC.
6900 NW 52th Street Miami, FL. 33166 - U.S.A. TOLL FREE: 1 888 DAS 4 USA
DAS Audio Asia PTE. LTD.
3 Temasek Avenue, Centennial Tower #34-36 Singapore 039190 Tel. +65 6549 7760
DAS do Brasil LTDA.
Rua Dos Andradas, 382 SL Santa Efigênia, São Paulo Brasil. CEP: 01208-000 Tel. +551133330764
Loading...