Danze D423058 Homeowner Manual [en, es, fr]

PARMA™
Dual Kitchen Faucet
Grifo para cocina a
función doble
Robinet de cuisine à
fonction double
Model / Modelo / Modèle
User Guide
Guido para operacion
Guide d'operation
Toll free service / Linea telefónica gratis / Numéro sans frais
US: 1-888-328-2383
Canada: 1-800-487-8372
About This Guide
Congratulations on your purchase of the Danze Parma Dual Kitchen faucet with spray. This faucet is designed to operate using the standard single control manual valve, or automatically without the need to touch a faucet part to start and stop the faucet stream. The hands free mode delivers water through the spout at a predetermined temperature, and will automatically shut off (you can set the timing), by activating the sensor located on the spout. When you have greasy or dirty hands, now you can start and stop the water without soiling the handle.
Table of Contents
PG
The guide is in English, Spanish and French languages for your convenience.
Before you begin , we recommend you review the installation steps as this faucet is unique.
About your Faucet
• Operates hands-free or with single control handle
• Durable, smooth operating ceramic disc valve
• Brass vegetable spray
• AC or DC power
• Timed shut-off hands-free operation
• Includes hook-up hoses and fittings
• For DC hook-up: uses four C type batteries, not included
• Includes a step-by-step installation demonstration video in DVD format
®
© 2009 Danze, Inc. All rights reserved.
English section
Spanish section
French section
1
7
13
1
Hands Free Operation
1.
After the unit has been installed, before turning on the unit, make sure that there is no obstruction in directly in front of the sensor lens. Then turn it on by pressing the ON-OFF switch on the control box to ON (I). Note: do NOT activate the waterflow until the led sensor light turns off ( for 10 seconds or so).
2.
For hands-free operation, the waterflow can be turned on by placing a hand (or other object) briefly in front of the electronic sensor (within about 3”) . The red indicator LED sensor light will blink and the waterflow will turn on and stay on for a factory-programmed 30 seconds.
3.
If the user wishes to stop the waterflow, simply place a hand in front of the sensor a second time. Again, the LED sensor light will blink and the waterflow will turn off.
Setting Temperature For Hands Free Operation
You can set the temperature of the water for hands free operation by adjusting the temperature control knob on the control box. Note: Be sure to have the manual faucet lever turned off or it will interfere with this setting.
Cold
Hot
®
© 2009 Danze, Inc. All rights reserved.
2
How To Change Flow-time Of Hands Free Operation
• locate the ON-OFF switch on the control box and switch to OFF (O) for a period of 5 seconds... then switch back to ON (I).
• You can program the flow time during the first 5 seconds after the power is switched on. During this 5 seconds a red light in the sensor window will turn on and stay lit for a 5 second period. To program, place your hand in front of the sensor while the light is on.
• As you keep your hand in front of the sensor the light will begin to blink at one second intervals. Each blink will account for a 5 second automatic run time (e.g. 4 blinks = 20 seconds). The maximum flow time is at 45 seconds or 9 blinks. Note: beyond 9 blinks the unit will set the maximum flow time (45 seconds).
• After the desired number of blinks, remove the hand, wait a few seconds and the sensor will blink 3 times to confirm the new run time.
• On power-off conditions the last programmed parameters are retained in memory.
Changing Batteries
• When the red light flashes continuously, the batteries need to be changed
• Remove the sensor control box cover by unscrewing the left hand screw
• Carefully unplug and remove the battery pack
• Remove old batteries and install 4 fresh “C” sized batteries (taking care to observe the required battery polarity) into the battery pack
• Re-insert battery pack into the sensor control box cavity and re-connect plug
• Re-install sensor control box cover taking care not to pinch wires.
• Turn on faucet by pushing ON-OFF switch to ON (1).
®
© 2009 Danze, Inc. All rights reserved.
3
Care + Maintenance
Your new faucet is designed for years of trouble-free performance. Keep it looking new by cleaning it periodically with a soft cloth. Avoid abrasive cleaners, steel wool and harsh chemicals as these will dull the finish and void your warranty.
Trouble-Shooting
Aerator leaks or has an inconsistent water flow pattern.
1.
• Remove aerator to check rubber packing or replace the aerator.
Hands Free Operation Trouble Shooting Guide
Confirm that the faucet is working properly in manual mode by operating the manual water handle. If the water flow can be properly turned on and off, turn off the manual activation and proceed to check the automatic functions as shown below.
1.
An object is within detection range but there is no water flow and the red light is not lit.
• Turn the power off and on using the NO-OFF switch on the sensor control box and confirm result.
• If the red light is still not lit, check the electronic power connections (AC plug in/battery/battery connection)
2.
An object is detected and the red light is on but there is no water flow.
• Check all water connections
• Check the electronic connections on control box under sink
• Check the filter on the solenoid valve and clean as necessary
• Check the spout nozzle and clean as necessary
3.
There is no object within detection range, the red light is on but the water flows continuously.
• Check to see whether the manual valve handle is open
• Check all water connections
• Check the solenoid valve electronic connections
®
© 2009 Danze, Inc. All rights reserved.
4
Hands Free Operation Trouble Shooting Guide
4.
There is no object within the detection range but the red light is continuously on.
• After first turning the unit on it will go into programming mode automatically for a few seconds. The light will turn off automatically after a few seconds.
• The unit is sensing a stationary object in front of the lens. This object may not be obvious to the user. The unit will reprogram itself and the light will turn off after a few seconds.
• If the light stays on indefinitely, the electronic module may be faulty
5.
The solenoid valve appears to be functioning incorrectly
• Check all water connections
• Check solenoid valve electronic connections
• When placing a hand in front of the sensor, check whether there is an audible “click” from the solenoid valve
• Check the filter on the solenoid valve and clean as necessary
• Change the solenoid valve
6.
The water flow is too low
• Check to make sure that the hot/cold inlet valves are fully open
• Check the filter on the solenoid valve and clean as necessary
• Check the spout nozzle and clean as necessary
7.
The mixed water does not have the desired temperature
• Turn the handle on the water mixer to change temperature – more towards the red or blue range if the mixed water temperature is too cold or too hot.
• Check hot and cold water hoses for proper connection
8.
Hands free activated water run time
• See installation instructions
®