Danfoss XB 12 Data sheet

Danfoss XB 12 Data sheet

Data sheet

Micro plate heat exchanger (MPHE): XB12

Description

Micro Plate Heat Exchangers - a revolutionary technology from Danfoss.

Characterized by their unique plate pattern, MPHEs enable heat to be transferred more efficient than any previous model of heat exchangers.

Benefits:

Energy and cost savings

Better heat transfer

Lower pressure loss

More flexible design

Longer life time

more on: districtenergy.danfoss.com (MPHE)

XB 12 is copper brazed heat exchanger, designed and configured for District Heating, District Cooling and other Heating applications. Heat exchanger XB12 will be available in plate corrugation H, M and L. It will be available in 1-pass (with 4 connections) and 2-pass version (with 6 connections). Heat exchangers can be dimensioned in Danfoss calculation software “Hexact” which can be downloaded from hexact.danfoss.com.

Approval:

Pressure Equipment Directive (PED) 97/23/EC.

Ordering

1) Available also with 1 inch connection size. Please contact your Danfoss representative.

1-pass heat exchanger XB12 with G 1 ¼” connection size 1)

Picture

No. of plates, n

Connection

XB 12H-1

XB 12M-1

XB 12L-1

 

Code No.

 

 

 

 

 

 

 

10

 

004H7555

004H7540

004H7525

 

16

 

004H7556

004H7541

004H7526

 

20

 

004H7557

004H7542

004H7527

 

26

 

004H7558

004H7543

004H7528

 

30

 

004H7559

004H7544

004H7529

 

36

 

004H7560

004H7545

004H7530

 

40

 

004H7561

004H7546

004H7531

 

50

Thread G 1 ¼”

004H7562

004H7547

004H7532

 

60

004H7563

004H7548

004H7533

 

 

 

70

 

004H7564

004H7549

004H7534

 

80

 

004H7565

004H7550

004H7535

 

90

 

004H7566

004H7551

004H7536

 

100

 

004H7567

004H7552

004H7537

 

110

 

004H7568

004H7553

004H7538

 

120

 

004H7569

-

-

 

140

 

004H7570

-

-

2-pass heat exchanger XB12 with G 1 ¼” connection size 1)

1)Available also with 1 inch connection size. Please contact your Danfoss representative.

2)first pass/second pass

Picture

No. of plates2), n

Connection

XB 12H-1

XB 12M-1

XB 12L-1

 

Code No.

 

 

 

 

 

 

 

20/20

 

004H7596

004H7584

004H7572

 

26/26

 

004H7597

004H7585

004H7573

 

30/30

 

004H7598

004H7586

004H7574

 

36/36

 

004H7599

004H7587

004H7575

 

40/40

 

004H7600

004H7588

004H7576

 

46/46

Thread G 1 ¼”

004H7601

004H7589

004H7577

 

50/50

 

004H7602

004H7590

004H7578

 

56/56

 

004H7603

004H7591

004H7579

 

60/60

 

004H7604

004H7592

004H7580

 

66/66

 

004H7605

004H7593

004H7581

 

70/70

 

004H7606

004H7594

004H7582

DEN-SMT/SI

VD.JQ.A2.02 © Danfoss 11/2015

1

Data sheet

Micro plate heat exchanger XB 12

 

 

Ordering (continued)

Accessories:

Insulation for 1-pass

1) EPP insulation is not available please order PU insulation for this size.

EPP (Expanded Polypropylene) insulation

No. of plates

Type coverage (plate number)

H

M

L

 

10

 

 

 

16

 

 

 

20

 

 

004H4201

26

004H4201

004H4201

 

30

 

 

 

36

 

 

 

40

 

 

004H4202

50

 

 

 

 

 

60

004H4202

004H4202

 

70

 

 

 

 

 

80

 

 

004H4203

90

 

004H4203

 

100

004H4203

1)

 

110

 

 

 

 

 

120

 

-

-

140

1)

-

-

 

PU (Polyurethane) insulation

No. of plates

Type coverage (plate number)

H

M

L

 

10

 

 

 

16

 

 

 

20

 

 

004H4210

26

004H4210

004H4210

 

30

 

 

 

 

 

36

 

 

 

40

 

 

 

50

 

 

004H4211

60

 

 

 

 

 

70

 

004H4211

 

80

004H4211

 

 

90

 

 

004H4212

100

 

004H4212

 

110

 

004H4213

 

 

120

004H4212

-

-

140

 

-

-

Accessories:

Insulation for 2-pass

1) EPP insulation is not available please order PU insulation for this size.

EPP (Expanded Polypropylene) insulation

No. of plates

Type coverage (plate number)

H

M

L

 

20/20

004H4201

004H4201

 

26/26

 

 

004H4202

30/30

004H4202

004H4202

 

36/36

 

 

 

 

 

40/40

 

 

004H4203

46/46

 

004H4203

 

50/50

004H4203

 

 

 

56/56

 

 

 

 

 

60/60

 

 

1)

 

 

 

 

 

 

 

66/66

 

1)

 

 

1)

 

 

70/70

 

 

 

Accessories-Tailpieces

Picture

Description

Connection

Code No.1)

 

 

G 1 ¼" / 28 mm

004B1358

 

Solder

G 1" / 22 mm

004B2906

 

tailpieces

G 1" / 18 mm

004B2905

 

 

G 1" / 15 mm

004B2904

 

 

G 1" / DN 20

003H6909

 

Weld-on

G 1" / DN 25

004B2903

 

tailpieces

G 1 ¼" / DN 25

003H6910

 

 

G 1 ¼" / DN 32

004B1343

 

Threaded

G 1 ¼" / G 1"

004H4205

 

G 1 ¼" / G 1 ½"

004H4206

 

tailpieces

 

G 1" / G ¾"

004B2913

 

 

1)One set contains 2 tailpieces with union nuts and gaskets

PU (Polyurethane) insulation

No. of plates

Type coverage (plate number)

H

M

L

 

20/20

004H4210

004H4210

 

26/26

 

 

 

 

004H4211

30/30

 

 

 

 

 

36/36

 

004H4211

 

40/40

004H4211

 

 

46/46

 

 

004H4212

50/50

 

 

 

56/56

 

004H4212

004H4213

60/60

 

004H4212

 

 

66/66

 

 

 

 

004H4214

70/70

 

004H4213

 

 

Accessories-Bracket 1)

Picture Connection Code No.

Thread

004H4200

G 1 ¼”

 

Thread

004B2919

G 1”

 

1)Bracket set consist of bracket and 2 seeger rings

Design and function

 

Danfoss 2 pass heat exchangers are made with

T11

-

Primary side in

 

6 connections, as they are primarily used to heat

 

tap water.

T12

-

Primary side out

 

There is one additional connection to allow

T112 -

Primary side second inlet

 

circulation of hot water and one connection to

T21

 

(2-pass)

 

connect and extract heat from return water from

-

Secondary side in

 

 

heating heat exchanger.

T22

-

Secondary side out

 

 

Connections T112 and T212 can be blocked if

T212 -

Secondary side second

 

 

they are not used.

 

 

inlet (2- pass)

 

2

 

VD.JQ.A2.02

© Danfoss 11/2015