Data sheet
Micro plate heat exchanger (MPHE): XB12
Description
Micro Plate Heat Exchangers - a revolutionary technology from Danfoss.
Characterized by their unique plate pattern, MPHEs enable heat to be transferred more efficient than any previous model of heat exchangers.
Benefits:
•Energy and cost savings
•Better heat transfer
•Lower pressure loss
•More flexible design
•Longer life time
more on: districtenergy.danfoss.com (MPHE)
XB 12 is copper brazed heat exchanger, designed and configured for District Heating, District Cooling and other Heating applications. Heat exchanger XB12 will be available in plate corrugation H, M and L. It will be available in 1-pass (with 4 connections) and 2-pass version (with 6 connections). Heat exchangers can be dimensioned in Danfoss calculation software “Hexact” which can be downloaded from hexact.danfoss.com.
Approval:
Pressure Equipment Directive (PED) 97/23/EC.
Ordering
1) Available also with 1 inch connection size. Please contact your Danfoss representative.
1-pass heat exchanger XB12 with G 1 ¼” connection size 1)
Picture |
No. of plates, n |
Connection |
XB 12H-1 |
XB 12M-1 |
XB 12L-1 |
|
Code No. |
|
|||
|
|
|
|
|
|
|
10 |
|
004H7555 |
004H7540 |
004H7525 |
|
16 |
|
004H7556 |
004H7541 |
004H7526 |
|
20 |
|
004H7557 |
004H7542 |
004H7527 |
|
26 |
|
004H7558 |
004H7543 |
004H7528 |
|
30 |
|
004H7559 |
004H7544 |
004H7529 |
|
36 |
|
004H7560 |
004H7545 |
004H7530 |
|
40 |
|
004H7561 |
004H7546 |
004H7531 |
|
50 |
Thread G 1 ¼” |
004H7562 |
004H7547 |
004H7532 |
|
60 |
004H7563 |
004H7548 |
004H7533 |
|
|
|
||||
|
70 |
|
004H7564 |
004H7549 |
004H7534 |
|
80 |
|
004H7565 |
004H7550 |
004H7535 |
|
90 |
|
004H7566 |
004H7551 |
004H7536 |
|
100 |
|
004H7567 |
004H7552 |
004H7537 |
|
110 |
|
004H7568 |
004H7553 |
004H7538 |
|
120 |
|
004H7569 |
- |
- |
|
140 |
|
004H7570 |
- |
- |
2-pass heat exchanger XB12 with G 1 ¼” connection size 1)
1)Available also with 1 inch connection size. Please contact your Danfoss representative.
2)first pass/second pass
Picture |
No. of plates2), n |
Connection |
XB 12H-1 |
XB 12M-1 |
XB 12L-1 |
|
Code No. |
|
|||
|
|
|
|
|
|
|
20/20 |
|
004H7596 |
004H7584 |
004H7572 |
|
26/26 |
|
004H7597 |
004H7585 |
004H7573 |
|
30/30 |
|
004H7598 |
004H7586 |
004H7574 |
|
36/36 |
|
004H7599 |
004H7587 |
004H7575 |
|
40/40 |
|
004H7600 |
004H7588 |
004H7576 |
|
46/46 |
Thread G 1 ¼” |
004H7601 |
004H7589 |
004H7577 |
|
50/50 |
|
004H7602 |
004H7590 |
004H7578 |
|
56/56 |
|
004H7603 |
004H7591 |
004H7579 |
|
60/60 |
|
004H7604 |
004H7592 |
004H7580 |
|
66/66 |
|
004H7605 |
004H7593 |
004H7581 |
|
70/70 |
|
004H7606 |
004H7594 |
004H7582 |
DEN-SMT/SI |
VD.JQ.A2.02 © Danfoss 11/2015 |
1 |
Data sheet |
Micro plate heat exchanger XB 12 |
|
|
Ordering (continued)
Accessories:
Insulation for 1-pass
1) EPP insulation is not available please order PU insulation for this size.
EPP (Expanded Polypropylene) insulation
No. of plates |
Type coverage (plate number) |
|||
H |
M |
L |
||
|
||||
10 |
|
|
|
|
16 |
|
|
|
|
20 |
|
|
004H4201 |
|
26 |
004H4201 |
004H4201 |
|
|
30 |
|
|
|
|
36 |
|
|
|
|
40 |
|
|
004H4202 |
|
50 |
|
|
||
|
|
|
||
60 |
004H4202 |
004H4202 |
|
|
70 |
|
|
||
|
|
|
||
80 |
|
|
004H4203 |
|
90 |
|
004H4203 |
|
|
100 |
004H4203 |
1) |
||
|
||||
110 |
|
|
||
|
|
|
||
120 |
|
- |
- |
|
140 |
1) |
- |
- |
|
|
PU (Polyurethane) insulation
No. of plates |
Type coverage (plate number) |
|||
H |
M |
L |
||
|
||||
10 |
|
|
|
|
16 |
|
|
|
|
20 |
|
|
004H4210 |
|
26 |
004H4210 |
004H4210 |
||
|
||||
30 |
|
|
||
|
|
|
||
36 |
|
|
|
|
40 |
|
|
|
|
50 |
|
|
004H4211 |
|
60 |
|
|
||
|
|
|
||
70 |
|
004H4211 |
|
|
80 |
004H4211 |
|
|
|
90 |
|
|
004H4212 |
|
100 |
|
004H4212 |
|
|
110 |
|
004H4213 |
||
|
|
|||
120 |
004H4212 |
- |
- |
|
140 |
|
- |
- |
Accessories:
Insulation for 2-pass
1) EPP insulation is not available please order PU insulation for this size.
EPP (Expanded Polypropylene) insulation
No. of plates |
Type coverage (plate number) |
|||
H |
M |
L |
||
|
||||
20/20 |
004H4201 |
004H4201 |
|
|
26/26 |
|
|
004H4202 |
|
30/30 |
004H4202 |
004H4202 |
|
|
36/36 |
|
|
||
|
|
|
||
40/40 |
|
|
004H4203 |
|
46/46 |
|
004H4203 |
|
|
50/50 |
004H4203 |
|
||
|
|
|||
56/56 |
|
|
||
|
|
|
||
60/60 |
|
|
1) |
|
|
|
|
||
|
|
|
|
|
66/66 |
|
1) |
|
|
|
1) |
|
|
|
70/70 |
|
|
|
Accessories-Tailpieces
Picture |
Description |
Connection |
Code No.1) |
|
|
G 1 ¼" / 28 mm |
004B1358 |
|
Solder |
G 1" / 22 mm |
004B2906 |
|
tailpieces |
G 1" / 18 mm |
004B2905 |
|
|
G 1" / 15 mm |
004B2904 |
|
|
G 1" / DN 20 |
003H6909 |
|
Weld-on |
G 1" / DN 25 |
004B2903 |
|
tailpieces |
G 1 ¼" / DN 25 |
003H6910 |
|
|
G 1 ¼" / DN 32 |
004B1343 |
|
Threaded |
G 1 ¼" / G 1" |
004H4205 |
|
G 1 ¼" / G 1 ½" |
004H4206 |
|
|
tailpieces |
||
|
G 1" / G ¾" |
004B2913 |
|
|
|
1)One set contains 2 tailpieces with union nuts and gaskets
PU (Polyurethane) insulation
No. of plates |
Type coverage (plate number) |
|||
H |
M |
L |
||
|
||||
20/20 |
004H4210 |
004H4210 |
|
|
26/26 |
|
|
||
|
|
004H4211 |
||
30/30 |
|
|
||
|
|
|
||
36/36 |
|
004H4211 |
|
|
40/40 |
004H4211 |
|
|
|
46/46 |
|
|
004H4212 |
|
50/50 |
|
|
|
|
56/56 |
|
004H4212 |
004H4213 |
|
60/60 |
|
|||
004H4212 |
|
|
||
66/66 |
|
|
||
|
|
004H4214 |
||
70/70 |
|
004H4213 |
||
|
|
Accessories-Bracket 1)
Picture Connection Code No.
Thread |
004H4200 |
|
G 1 ¼” |
||
|
||
Thread |
004B2919 |
|
G 1” |
||
|
1)Bracket set consist of bracket and 2 seeger rings
Design and function |
|
Danfoss 2 pass heat exchangers are made with |
||
T11 |
- |
Primary side in |
|
6 connections, as they are primarily used to heat |
|
tap water. |
|||
T12 |
- |
Primary side out |
|
There is one additional connection to allow |
T112 - |
Primary side second inlet |
|
circulation of hot water and one connection to |
|
T21 |
|
(2-pass) |
|
connect and extract heat from return water from |
- |
Secondary side in |
|
||
|
heating heat exchanger. |
|||
T22 |
- |
Secondary side out |
|
|
|
Connections T112 and T212 can be blocked if |
|||
T212 - |
Secondary side second |
|
||
|
they are not used. |
|||
|
|
inlet (2- pass) |
|
|
2 |
|
VD.JQ.A2.02 |
© Danfoss 11/2015 |
DEN-SMT/SI |