traction control for hydrostatic systems
with one pump and two motors in
parallel. In normal operation, uid
passes freely through the valve. When
the solenoid is energized, uid is forced
through the ow divider/combiner,
preventing wheel spin or motor over
speed.
PERFORMANCE
Performance curve
DIMENSIONS
mm [in]
Approx.
Schematic
Specications
Rated pressure207 bar [3000 psi]
Rated ow at 7 bar
[100 psi]
Weight2.79 kg [6.15 lb]
Bypass Cracking Pressure 3.1 bar [45 psi]
45 l/min
[12 US gal/min]
107 [4.25]
69.9 [2.75]
50.8 [2.00]
0.0
0.0
63.5 [2.50]
ORDERING
50.8 [2.00]
22.4 [0.88]
12.7 [0.50]
0.0
50.8 [2.00]
0.0
0.0
12.7 [0.50]
31.8 [1.25]
44.5 [1.75]
63.5 [2.50]
76.2 [3.00]
88.9 [3.50]
8.74 [0.344]
0.0
63.5 [2.50]
88.9 [3.50]
INFORMATION
BC332376200116en-000101 • February 2020
TR- 1
Traction Control HIC Technical Information
13610268
0
psi
US gal/min
bar
21
14
L/min
Pressure drop
33 cSt [154 SUS] hyd.oil at 38°C [100 °F]
34
7
0
100
200
0
28
35
300
1632
Flow
BYPASS
170
82440
500
400
2020
1212
0909
1515
X05-FD16 Traction Manifold
OPERATION
PERFORMANCE
DIMENSIONS
mm [in]
This valve provides electrically actuated
traction control for hydrostatic systems
with one pump and two motors in
parallel. In normal operation, uid
passes freely through the valve. When
the solenoid is energized, uid is forced
through the ow divider/combiner,
preventing wheel spin or motor over
speed.
Performance curve
Schematic
Specications
Rated pressure350 bar [5075 psi]
Rated ow at 7 bar
[100 psi]
Weight4.48 kg [9.88 lb]
Bypass cracking pressure 3.8 bar [55 psi]
150 l/min
[40 US gal/min]
ORDERING
INFORMATION
BC332376200116en-000101 • February 2020
TR- 2
Traction Control HIC Technical Information
X05-FD104 Traction Manifold
OPERATIONSchematic
This valve provides electrically actuated
traction control for hydrostatic systems
with one pump and four motors in
parallel. In normal operation, uid
passes freely through the valve. When
the solenoid is energized, uid is forced
through the ow divider/combiners. The
result is equal ow to all four motors,
preventing wheel spin or motor over
speed.
PERFORMANCEPerformance curve
Pressure drop
33 cSt [154 SUS] hyd.oil at 38°C [100 °F]
bar
psi
70
1000
33
800
600
400
200
56
42
28
14
0
0
0606
50
25
1224
61830
0
1212
66
BYPASS
Flow
75
100
125
US gal/min
L/min
Specications
Rated pressure207 bar [3000 psi]
Rated ow at 7 bar
[100 psi]
Weight8.74 kg [19.74 lb]
Bypass cracking pressure3.1 bar [45 psi]
ORDERING
INFORMATION
DIMENSIONSSee next page.
45 l/min
[12 US gal/min]
BC332376200116en-000101 • February 2020
TR- 3
DIMENSIONS
mm [in]
Traction Control HIC Technical Information
X05-FD104 Traction Manifold
1/2-13 UNC-2B
25.4 [1.00] MINGD THD
2PLCS
BC332376200116en-000101 • February 2020
TR- 4
Traction Control HIC Technical Information
13610268
0
psi
US gal/min
bar
41
28
L/min
Pressure drop
33 cSt [154 SUS] hyd.oil at 38°C [100 °F]
34
14
0
200
400
0
55
69
600
1632
Flow
BYPASS
170
82440
1000
800
2020 / 0909
1212 / 0606
0909 / 0505
X05 - FD164 - S12S - 0909 - 2020 - H12D - DE - B
Motor Flow Division
Port A Flow Division
Traction Control Solenoid
X05-FD164 Traction Manifold
OPERATIONSchematic
This valve provides electrically actuated
traction control for hydrostatic systems
with one pump and four motors in
parallel. In normal operation, uid
passes freely through the valve. When
the solenoid is energized, uid is forced
through the ow divider/combiners. The
result is equal ow to all four motors,
preventing wheel spin or motor over
speed.
PERFORMANCEPerformance curve
Specications
Rated pressure350 bar [5075 psi]
Rated ow at 7 bar
[100 psi]
Weight14.57 kg [32.12 lb]
Bypass cracking pressure4 bar [55 psi]
ORDERING
INFORMATION
DIMENSIONSSee next page.
BC332376200116en-000101 • February 2020
150 l/min
[40 US gal/min]
TR- 5
DIMENSIONS
mm [in]
Traction Control HIC Technical Information
X05-FD164 Traction Manifold
BC332376200116en-000101 • February 2020
TR- 6
Traction Control HIC Technical Information
barpsi
LFB12
OPERATION &
APPLICATION
The Loop Flushing Block allows oil to
drain from the power transmission loop
to other oil treatment components.
The low pressure side of the circuit is
directed to the relief valve, which is then
drained out of the transmission loop.
This HIC is typically used in closed
loop circuits to assist in the process of
removing contamination and cooling
oil. Hydrostatic systems with sustained
operation and continuous pressure
will benet from a loop ushing circuit.
To congure the LFB12, determine the
charge pump pressure and desired
ushing ow. Working up from the
desired ow, select the orice size
with a pressure rise that, when added
to one of the available relief settings
(in the ordering information section),
meets the charge pump pressure.
Specications
Rated pressure 350 bar [5075 psi]
Rated owSee performance chart
Weight3.4 kg [7.5 lb]
ValvesCP721-3 [Shuttle]
CP210-1 [Relief]
M12 orice plug
MaterialDuctile Iron
Schematic
Open CenterClosed Center
DR
GAGAGBGB
DR
BABA
PERFORMANCE
CHART
20
250
15
200
150
10
100
Charge pressure minus relief se�ng
5
50
0
0
01020304050
024681012
Pressure rise per orice option
33 cSt [154 SUS] hyd. oil at 38°C [100°F]
2.5m m
3.0mm3.5 mm4 .0mm4.5m m5 .0mm
Flow
None
lpm
gpm
BC332376200116en-000101 • February 2020
TR- 7
DIMENSIONS
mm [in]
Traction Control HIC Technical Information
LFB12
ORDERING
INFORMATION
LFB12 - C - 17 - 3.0 - B - S8S
Spool Center
C = Closed
O = Open
Relief Setting
07 = 07 bar [100 psi]
10 = 10 bar [150 psi]
14 = 14 bar [200 psi]
17 = 17 bar [250 psi]
21 = 21 bar [300 psi]
24 = 24 bar [350 psi]
28 = 28 bar [400 psi]
BC332376200116en-000101 • February 2020
Orifi ce Option
00 = None
2.5 = ø2.5mm
3.0 = ø3.0mm
3.5 = ø3.5mm
4.0 = ø4.0mm
4.5 = ø4.5mm
5.0 = ø5.0mm
Port Sizes
S8S = 8S SAE [A, B, & DR]
S4B = ½ BSP [A, B, & DR]
Seal Material
B = Buna
V = Viton
6S SAE [GA & GB]
¼ BSP [GA & GB]
TR- 8