Danfoss X05-FD10 Technical Information

Traction Control HIC Technical Information
167.4 [6.59]
Thru -2 Plcs.
382819
0
psi
US gal/min
bar
21
14
L/min
Pressure drop
33 cSt [154 SUS] hyd.oil at 38°C [100 °F]
9
7
0
100
200
0
28
35
300
4.8 9.6
Flow
BYPASS
50
2.4 7.2 12
500
400
66
33
11
X05-FD10 Traction Manifold
OPERATION This valve provides electrically actuated
traction control for hydrostatic systems with one pump and two motors in parallel. In normal operation, uid passes freely through the valve. When the solenoid is energized, uid is forced through the ow divider/combiner, preventing wheel spin or motor over speed.
PERFORMANCE
Performance curve
DIMENSIONS
mm [in]
Approx.
Schematic
Specications
Rated pressure 207 bar [3000 psi]
Rated ow at 7 bar
[100 psi]
Weight 2.79 kg [6.15 lb]
Bypass Cracking Pressure 3.1 bar [45 psi]
45 l/min
[12 US gal/min]
107 [4.25]
69.9 [2.75]
50.8 [2.00]
0.0
0.0
63.5 [2.50]
ORDERING
50.8 [2.00]
22.4 [0.88]
12.7 [0.50]
0.0
50.8 [2.00]
0.0
0.0
12.7 [0.50]
31.8 [1.25]
44.5 [1.75]
63.5 [2.50]
76.2 [3.00]
88.9 [3.50]
8.74 [0.344]
0.0
63.5 [2.50]
88.9 [3.50]
INFORMATION
BC332376200116en-000101 • February 2020
TR- 1
Traction Control HIC Technical Information
13610268
0
psi
US gal/min
bar
21
14
L/min
Pressure drop 33 cSt [154 SUS] hyd.oil at 38°C [100 °F]
34
7
0
100
200
0
28
35
300
16 32
Flow
BYPASS
170
8 24 40
500
400
2020
1212
0909
1515
X05-FD16 Traction Manifold
OPERATION
PERFORMANCE
DIMENSIONS
mm [in]
This valve provides electrically actuated traction control for hydrostatic systems with one pump and two motors in parallel. In normal operation, uid passes freely through the valve. When the solenoid is energized, uid is forced through the ow divider/combiner, preventing wheel spin or motor over speed.
Performance curve
Schematic
Specications
Rated pressure 350 bar [5075 psi]
Rated ow at 7 bar
[100 psi]
Weight 4.48 kg [9.88 lb]
Bypass cracking pressure 3.8 bar [55 psi]
150 l/min
[40 US gal/min]
ORDERING INFORMATION
BC332376200116en-000101 • February 2020
TR- 2
Traction Control HIC Technical Information
X05-FD104 Traction Manifold
OPERATION Schematic
This valve provides electrically actuated traction control for hydrostatic systems with one pump and four motors in parallel. In normal operation, uid passes freely through the valve. When the solenoid is energized, uid is forced through the ow divider/combiners. The result is equal ow to all four motors, preventing wheel spin or motor over speed.
PERFORMANCE Performance curve
Pressure drop 33 cSt [154 SUS] hyd.oil at 38°C [100 °F]
bar
psi
70
1000
33
800
600
400
200
56
42
28
14
0
0
0606
50
25
12 24
6 18 30
0
1212
66
BYPASS
Flow
75
100
125
US gal/min
L/min
Specications
Rated pressure 207 bar [3000 psi]
Rated ow at 7 bar
[100 psi]
Weight 8.74 kg [19.74 lb]
Bypass cracking pressure 3.1 bar [45 psi]