Danfoss WT-T, WT-D, WT-DR, WT-PR, WT-P Data sheet

Data Sheet
Basic Plus
2
Floor Heating Room Thermostats
Application
WT-T WT- D/WT-DR WT- P/WT-PR
All room thermostats are used for room tempera­ture control in water-based oor heating systems. By controlling room temperature in accordance with the temperature desired by the user, the room thermostats provide optimal energy savings while upholding optimal thermal comfort in the room.
Functions
Room Thermostat, WT-T (Dial)
By turning the dial to the desired setpoint tem­perature, optimal thermal comfort in the room is achieved. In addition to temperature, the thermo­stat setting scale includes a frost symbol allowing for minimal energy consumption while avoiding freezing temperatures in the room. The thermostat is equipped with diodes, which display a green light through the front cover while the thermostat is ON, but without heat demand. A red light is displayed when the thermostat is ON and there is heat demand.
Features of Room Thermostats, WT- D (display) and WT-P (display and programmable):
• Modern design with white backlight.
• AWAY function.
• Child safety lock.
• 3 selectable temperature control modes:
1. Room temp. control (default).
2. Room with oor temp. limit control.
3. Floor temp. control.
• 2 selectable oor temperature control modes:
1. High
2. Low
• Max. and min. limit settings for room and oor temperature.
• Optional room temperature display when power is OFF (default setting: no display).
Room Thermostats, WT- DR (display) and WT-PR (display and programmable)
The thermostats have voltage-free auxiliary SPST relay for controlling the external equipment, such as a boiler. Additional features:
Other functionalities are identical with those listed for WT-D and WT-P.
• Floor sensor terminals. For thermostats equipped with LCD display, enabling control of maximum oor temperature and reducing the risk of overheated and damaged oors (for specic maximum oor temperatures, refer to the recommendations from oor suppliers).
• Frost protection mode. Use this feature instead of turning the thermostat OFF com­pletely to protect against damages due to low temperatures. The room temperature will be maintained around 5° C.
• Temperature calibration. This function allows you to change the temperature setpoint of the room thermostat, to compensate for a possible temperature deviation between the room thermostat and, for example, the centre of the room.
• Advanced programmable timer. This function allows you to set a timer-controlled program for automatic comfort temperature and energy­saving lower setback temperature when stand­ard room comfort temperature is not required.
• Programmable 5/2-day feature with 4 time segments (WT-P & -PR).
• Clock in 12-hour or 24-hour format (WT-P & -PR).
VDCUC302
© Danfoss | FHH | 2015.09 | 1
Data Sheet Basic Plus2 Floor Heating Room Thermostats
ErP
1
Ordering
Accessories
Technical specications
Product Typ e
Basic Plus2 WT-T Toggle WT-T 230 V AC 230 V AC 088U0620
Basic Plus2 WT-D Display WT-D 85–250 V AC 85–250 V AC 088U0622
Basic Plus2 WT-DR Display and Relay WT-DR 85–250 V AC 85–250 V AC 088U0624
Basic Plus2 WT-P Programmable WT-P 85–250 V AC 85–250 V AC 088U0625
Basic Plus2 WT-PR Programmable and Relay WT-PR 85–250 V AC 85–250 V AC 088U0626
Product Typ e Code no.
BasicPlus oor sensor FH-CWF 088U0610
Feature WT-T WT-D/DR WT- P/PR
Typ e Dial with LED indicator
Operating room temperature
Operating oor temperature
Ambient temperature -10 - 60° C
Fault indication - Yes
Hysteresis
LCD backlight - Yes, white
Max. load, inductive < 1 A
Max. load, resistive < 3 A
Auxiliary relay - Volt-free relay (WT-DR and WT-PR), e.g. boiler
Temperature calibration No Yes (+/-10° C)
Power consumption 7 W 2 W
Power supply
Sensor, room
Sensor, oor - Optional (FH-CWF)
Shell material ABS, non-inammable
IP class 30
O, 5 - 30° C O, 5 - 35° C
- O, 20 - 45° C
1° C, below the
setpoint temperature
230 V AC ±10 %,
50/60 Hz
NTC 10K,
accuracy: ±1%
Supply
voltage
LCD display with
push buttons
1° C, symmetrical around
the setpoint temperature
Output
voltage
LCD display with
programmable
85–250 V AC,
50/60 Hz
NTC 100K,
accuracy: ±1%
Code no.
push buttons,
2 | © Danfoss | FHH | 2015.09
ErP class
Approval CE marking, EN 60730
Colour White RAL9010/Dark Grey RAL7024
Dimensions 86 × 86 × 30 mm 86 × 86 × 16.0 mm
(1%)
VDCUC302
Loading...