Danfoss VLT HVAC Drive Fact sheet

Fact Sheet
VLT® HVAC Drive
The VLT® HVAC Drive is a full-featured, HVAC dedicated drive with built-in intelligence. It has a vast number of functions developed to meet the diverse needs of the HVAC business. It is the perfect match for pumps, fans and compressors in modern buildings that are fitted with increasingly sophisticated solutions.
Perfect
Product range:
1 x 200 – 240 V . . . . . . . . . . . . . . . . . . . . .1.5 – 30 HP
3 x 200 – 240 V . . . . . . . . . . . . . . . . . . . .1.5 – 200 HP
3 x 380 – 480 V . . . . . . . . . . . . . . . . . . 1.5 – 1350 HP
3 x 600 V . . . . . . . . . . . . . . . . . . . . . . . . . 1.5 – 1550 HP
3 x 690 V . . . . . . . . . . . . . . . . . . . . . . . . . 1.5 – 1900 HP
Available enclosure ratings:
NEMA/UL Type 1/IP21 ............1.5–1900 HP
NEMA/UL Type 12/IP54 . . . . . . . . . . 150–1900 HP
NEMA/UL Type 12/IP55 . . . . . . . . . . . . 1.5–125 HP
NEMA/UL Type 3R . . . . . . . . . . . . . . . . . . 1.5–125 HP
NEMA/UL Type 4X/IP66 . . . . . . . . . . . . .1.5–125 HP
With 110% overload torque
Feature Benet
All built-in – low investment
Modular product concept and a wide range of options
Dedicated HVAC I/O functionality for temperature sensors etc.
Decentral I/O control via serial communication
Wide range of HVAC protocols for BMS controller connectivity
4 x auto tuned PID’s No external PID controllers required
Smart Logic Controller Often makes external controller unnecessary
Real Time Clock Enables daily and weekly settings Integrated fan, pump and compressor
functionality Fire Override Mode, Dry Run Detection
Variable or Constant Torque
Condition Based Monitoring
Save energy – less operation cost
Automatic Energy Optimizer function, advanced version Advanced energy monitoring Overview on energy consumption
Energy saving functions i.e. flow compensation, sleep mode
Unequalled robustness – maximum uptime
Robust single enclosure Maintenance-free Unique cooling concept with no ambient air flow over electronics Max ambient temp. 50˚ C without derating No external cooling or derating necessary
User friendly – save commissioning and operating cost
Smart Start Quick and precise start-up Award winning graphic display, 27 languages Effective commissioning and operation USB plug and play connection Easy to use PC software tools Global HVAC support organization Local service – globally
Low initial investment – max. flexibility, later upgrade possible
External conversion saved
Reduced wiring costs and fewer controller I/O needed
Less extra gateway solutions needed
Reduces external control and conversion equipment needs
Protects equipment and saves energy
Monitor motor and application to prevent equipment downtime
Saves 5 – 15% energy
Saves energy
Problem-free operation in harsh environments
Built-in DC coils and RFI lters – no EMC concerns
Integrated DC link harmonic filters Small power cables. Meets EN 61000-3-12 Integrated EMC filters Meets EN 55011 Class B, A1 or A2
www.danfossdrives.com
Application options
A wide range of integrated HVAC options can be fitted in the drive:
General purpose I/O option (MCB 101)
3 digital inputs, 2 digital outputs, 1 analog current output, 2 analog voltage inputs. Relay option (MCB 105)
Adds 3 relay outputs
Analog I/O option (MCB 109)
3 Pt1000/Ni1000 inputs, 3 analog voltage outputs
External 24 VDC supply (MCB 107)
24 VDC external supply can be connected to supply control and option cards when main power is disconnected. Extended Relay option (MCB 113)
Adds 7 digital inputs, 4 - Form C relays and 2 analog outputs and mounts in the drive’s C option slot. Brake chopper option
Connected to an external brake resistor, the built-in brake chopper limits the DC bus voltage when the motor acts as generator. AC line protection options
Built in disconnect and fuses available
Power options
A wide range of external power options are available for VLT® HVAC Drive in critical power applications:
Advanced harmonic lters: For critical
limitations on harmonic distortion dV/dt lters: For special demands
on motor insulation protection Sine wave lters: (LC filters)
For noiseless motor and when long motor leads are required
HVAC PC software tools
MCT 10: Ideal for commissioning and
servicing the drive VLT® Energy Box: Comprehensive energy
analysis tool, shows the drive payback time MCT 31: Harmonic analysis tool
Power supply (L1, L2, L3)
Supply voltage 200–240 V ±10% Supply voltage 380–480 V ±10% Supply voltage 525–600 V ±10% Supply frequency 50/60 Hz Displacement Power Factor (cos φ) near unity (> 0.98) Switching on input supply L1, L2, L3 1–2 times/min.
Output data (U, V, W)
Output voltage 0 –100% of supply voltage Switching on output Unlimited Ramp times 1–3600 sec. Open/Closed loop 0–1000 Hz
Digital inputs
Programmable digital inputs 6* Logic PNP or NPN Voltage level 0–24 VDC
* 2 can be used as digital outputs
Pulse inputs
Programmable pulse inputs 2* Voltage level 0–24 VDC (PNP positive logic) Pulse input accuracy (0.1–110 kHz)
* Utilize some of the digital inputs
Analog input
Analog inputs 2 Modes Voltage or current Voltage level 0 V to +10 V (scaleable) Current level
Analog output
Programmable analog outputs 1 Current range at analog output 0/4–20 mA
Relay outputs
Programmable relay outputs 2 (240 VAC, 2 A and 400 VAC, 2 A)
Fieldbus communication
Standard built-in:
FC Protocol N2 Metasys FLN Apogee Modbus RTU BACnet
OSHPD Special Seismic Certication
Pre-Approval Certification expedites seismic authorization by
0/4 to 20 mA (scaleable)
Optional:
LonWorks (MCA 108) BACnet (MCA 109) DeviceNet (MCA 104) Profibus (MCA 101) Profinet SRT Ethernet IP Modbus TCP
regulatory agencies.
Tel. +1 (888) DANFOSS | www.danfossdrives.com | E-mail: salesinformation@danfoss.com Danfoss Drives: Houston, TX • Loves Park, IL • Milwaukee, WI • Raleigh, NC • Oakville, ON
USDD. PFP.102.A1.22 © Copyright Danfoss Drives | 2021.04