Danfoss VLT HVAC Drive, VLT AQUA Drive, VLT AutomationDrive Installation guide

VLT® HVAC Drive, VLT® AQUA Drive, VLT® AutomationDrive
1. Instruction Note for Installation in the C Slot
Mounting kit depending on frame Order no. Bookstyle
A2 and A3 (40mm for one C option) 130B7530 A2 and A3 (60mm for C0 + C1 option) 130B7531 B3 (40mm for one C option) 130B1413 B3 (60mm for C0 + C1 option) 130B1414
Compact
A5 130B7532
1.1 Bookstyle
Prepare the mounting kit:
1. Release the front with a screw driver.
2. Remove the support plate by releasing the two screws (turn slightly).
3. Remove the plastic cover by unscrewing the two screws.
Prepare the frequency converter:
4. Remove the LCP cradle from the frequency converter to access the connection point for the at cable. Cut the plastic part illustrated in order to get access between the frequency converter and the C option (see illustration A).
5. If a D option (24V DC) is installed, temporarily remove this.
6. Connect the at cable to the frequency converter and let it through the hole in the metal frame.
7. The metal frame attaches to the frequency converter through four metal parts that t into holes on the side of the frequency converter. The two parts in the back are xed with plastic snaps and the front is xed via two screws.
8. Mount the support plate.
9. Install the option. Mount the various parts that were removed for access again.
10. If an MCO 305 is used with CAN, cut out the plastic parts above the connectors and mount the cable relief (see illustration B).
NOTE
Do not mount the small fan for MCB 113, MCF 106 or frame sizes B4, C3, C4, D, E, and F.
A
130BA248.11
B
12 13 18 19 27 29 32 33 20
1
RemoveJumper to activate Safe Stop
2
130BB457.11
1. The 40mm mounting kit is used when only one C option is used.
2. The 60mm mounting kit is used for the MCF 106 Adaptor and also when more than one C option is used, i.e. one C0 plus one C1 option (not included in the adaptor).
MI.90.R2.02 - VLT® is a registered Danfoss trademark
1
VLT® HVAC Drive, VLT® AQUA Drive, VLT® AutomationDrive
130BB184.10
Frame sizes A2, A3, and B3. The 60mm mounting kit is used for the MCF 106 Adaptor. Special guides are used to mount and access the adaptor. Please see the MCF 106 A/B in C Option Adaptor Instruction, MI38F102 for more details on this special installation.
1.2 Compact
1. Remove the cover of the frequency converter.
2. Connect the at cable and install the C option.
3. Mount the various parts of the mounting kit.
130BA250.11
Frame sizes A5 through F (except B4) Frame size B4
130R0185
*MI90R202*
Rev. 2011-01-12