Sequence Valves Technical Information
Unloading Valve, Differential Area, Pilot Operated
VDB 06-EN
OPERATION |
This is a pilot-operated unloading valve. |
Schematic
SPECIFICATIONS |
Theoretical performance |
|
|
|
|
||||
|
psi |
bar |
26 mm²/sec (cSt) [124 SUS] @ 50°C [122° F] |
|
|
|
|||
|
|
|
40 |
|
|
|
|||
|
|
|
|
|
|
|
|
|
|
|
500 |
|
|
|
|
|
|
|
|
|
400 |
|
30 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
300 |
|
20 |
|
Piloted open |
|
|
|
|
|
200 |
|
|
|
|
|
|
Specifications |
|
|
|
|
10 |
|
|
|
|
|
|
|
100 |
|
|
|
|
|
Rated pressure |
350 bar [5075 psi] |
|
|
|
|
|
|
|
|
|||
|
0 |
|
0 |
|
|
|
|
Rated flow |
80 l/min |
|
|
|
|
|
|
|
[21 US gal/min] |
||
|
|
|
l/min |
20 |
40 |
60 |
80 |
|
|
|
|
|
Weight |
0.21 kg [0.46 lb] |
|||||
|
|
|
0 |
5 |
10 |
15 |
20 |
||
|
|
|
Cavity |
NCS06/3 |
|||||
|
Flow |
US gal/min |
|
|
|
||||
|
|
|
|
|
|
||||
DIMENSIONS |
Cross-sectional view |
|
|
|
|
||||
mm [in] |
|
|
|
|
|||||
|
27 mm |
|
|
|
|
|
|
|
|
44-50 N·m |
M 22 x 1.5 |
|
|
[32-37 lbf·ft] |
|
1
|
3 |
2 |
|
|
|
88.0 |
|
62.0 |
[3.47] |
|
[2.44] |
ORDERING |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
INFORMATION |
VDB 06-EN - 2 - A - SE3/8 - V |
|
|
|
|
|||||||||||||||
|
|
|
|
|
|
|
||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Seals |
Seal kit |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
Setting range |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
V = Viton |
230000110 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
1 = 25 - 140 bar [362 - 2031 psi] |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Omit = Buna-N 230000070 |
|||
2 = 70 - 210 bar [1015 - 3046 psi] |
|
|
|
|
|
|
|
|
|
Housing and po rts |
Housing P/N |
|||||||||
3 = 105 - 350 bar [15235076 psi] |
|
|
|
|
|
|
|
|
|
|||||||||||
|
|
|
|
|
00 |
|
= No Housing |
No Housing |
||||||||||||
|
|
|
|
|
|
|
|
|
||||||||||||
Pilot ratio |
|
|
|
|
|
|
|
|
|
|
|
SE3/8 |
= AL, 3/8 BSP |
NCS06/3-SE-3/8 |
||||||
|
|
|
|
|
|
|
|
|
|
|
SE1/2 |
= |
AL, ½ BSP |
NCS06/3-SE-1/2 |
||||||
|
|
|
|
|
|
|
||||||||||||||
A = 7.1 :1 |
|
|
|
|
|
|
|
|
|
SE6S |
= |
AL, #6 SAE |
NCS06/3-SE-6S |
|||||||
B = 4.1 :1 |
|
|
|
|
|
|
|
|
|
SE8S |
= |
AL, #8 SAE |
NCS06/3-SE-8S |
E = 1 :1 |
Other housings available |
|
To order this valve with a speci c factory setting, contact your Danfoss ICS representative
BC332375508106en-000101 • February 2020 |
SQ - 21 |