Danfoss TLS4.5F Data sheet

Danfoss TLS4.5F Data sheet

TLS4.5F

Standard Compressor

R134a

115V 60Hz

General

Code number

 

 

 

 

 

102G3420

 

 

 

Approvals

 

 

 

 

 

UL984

 

 

 

Compressors on pallet

 

 

 

 

 

125

 

 

 

Application

 

 

 

 

 

 

 

 

 

 

 

Application

 

 

 

 

 

LBP

 

 

 

Frequency

 

Hz

 

50

 

 

 

60

 

 

Evaporating temperature

 

°F

 

 

 

 

-31 to 23

Voltage range

 

V

 

 

 

 

103 - 127

Max. condensing temperature continuous (short)

°F

 

 

 

 

140 (158)

Max. winding temperature continuous (short)

°F

 

 

 

 

257 (257)

Cooling requirements

 

 

 

 

 

 

 

 

 

 

 

Frequency

 

Hz

 

50

 

 

 

60

 

 

Application

 

 

LBP

 

MBP

HBP

 

LBP

MBP

 

HBP

90°F

 

 

 

 

S

 

100°F

 

 

 

 

S

 

110°F

 

 

 

 

S

 

Remarks on application:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Motor

 

 

 

 

 

 

 

 

 

 

 

Motor type

 

 

 

 

 

RSIR/CSIR

 

 

 

LRA (rated after 4 sec. UL984), HST | LST

A

 

14.2

 

 

 

12.2

 

 

Cut in Current, HST | LST

 

A

 

14.2

 

 

 

22.6

 

 

Resistance, main | start winding (77°F)

 

3.2

 

 

 

3.4

 

 

Design

 

 

 

 

 

 

 

 

 

 

 

Displacement

 

cu.in

 

 

 

0.29

 

 

 

Oil quantity (type)

 

fl.oz.

 

 

6.1 (polyolester)

 

Maximum refrigerant charge

 

oz.

 

 

 

14.0

 

 

 

Free gas volume in compressor

 

fl.oz.

 

 

 

60.7

 

 

 

Weight without electrical equipment

lbs.

 

 

 

14.7

 

 

 

Dimensions

 

 

 

 

 

 

 

 

 

 

 

Height

 

inch

A

 

 

6.42

 

 

 

 

 

 

B

 

 

6.26

 

 

 

 

 

 

B1

 

 

 

 

 

 

 

 

 

B2

 

 

 

 

 

 

Suction connector

location, I.D. in. | angle

C

0.252-0.259 | 30°

 

 

 

material | comment

 

Cu-plated steel | Al cap

 

Process connector

location, I.D. in. | angle

D

0.252-0.259 | 31.5°

 

 

 

material | comment

 

Cu-plated steel | Al cap

 

Discharge connector

location, I.D. in. | angle

E

0.202-0.205 | 28°

 

 

 

material | comment

 

Cu-plated steel | Al cap

 

Oil cooler connector

location, I.D. in. | angle

F

 

 

 

 

 

 

 

material | comment

 

 

 

 

 

 

 

Remarks:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S = Static cooling normally sufficient

O= Oil cooling

F1

= Fan cooling 1.5 m/s

 

(compressor compartment temperature

 

equal to ambient temperature)

F2

= Fan cooling 3.0 m/s necessary

SG

= Suction gas cooling normally sufficent

= not applicable in this area

June 2012

Manufactured by Secop for Danfoss - DEHC.ED.401.D6.22 / 520N1362

1/2

ASHRAE LBP

 

 

115V, 60Hz, static cooling, PTC consumption incl.

 

 

 

 

 

 

 

 

 

 

 

 

Evap. temp. in °F

-49

-40

-30

-20

 

-13

-10

0

10

14

 

20

30

40

41

45

50

59

68

Capacity in BTU/h

 

 

245

340

 

431

477

654

875

975

 

1135

 

 

 

 

 

 

 

 

Power cons. in W

 

 

92

110

 

123

129

150

174

184

 

199

 

 

 

 

 

 

 

 

Current cons. in A

 

 

1.87

1.93

1.99

2.02

2.13

2.27

2.33

 

2.41

 

 

 

 

 

 

 

 

EER in BTU/Wh

 

 

2.66

3.10

3.50

3.69

4.34

5.03

5.31

 

5.71

 

 

 

 

 

 

 

 

EN 12900 Household (CECOMAF) 115V, 60Hz, static cooling, PTC consumption incl.

 

 

 

 

 

 

 

 

 

 

 

 

Evap. temp. in °F

-49

-40

-30

-20

 

-13

-10

0

10

14

 

20

30

40

41

45

50

59

68

Capacity in W

 

 

58

80

 

102

113

155

208

231

 

269

 

 

 

 

 

 

 

 

Power cons. in W

 

 

92

110

 

123

129

150

174

184

 

199

 

 

 

 

 

 

 

 

Current cons. in A

 

 

1.87

1.93

1.99

2.02

2.13

2.27

2.33

 

2.41

 

 

 

 

 

 

 

 

COP in W/W

 

 

0.63

0.73

0.83

0.87

1.03

1.19

1.26

 

1.35

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Accessories for

TLS4.5F

Figure

Code number

 

 

 

 

PTC starting device

1/4 in. spade connect.

a1

103N0003

 

3/16 in. spade connect.

103N0023

 

 

Starting Relay

 

a2

117U6003

Start. capacitor 240 µF

1/4 in. spade connect.

c

117U5023

Cover

 

b

103N2011

Cord relief

 

d

103N1010

Test conditions

ASHRAE

EN 12900/

 

LBP

CECOMAF

 

 

 

Condensing temp.

130°F

131°F

Ambient temp.

90°F

90°F

Suction gas temp

90°F

90°F

Liquid temperature

90°F

131°F

Mounting accessories

 

Code number

Bolt joint for one comp. Ø: 5/8 in.

118-1917

Bolt joint in quantities

Ø: 5/8 in.

118-1918

Snap-on in quantities

Ø: 5/8 in.

118-1919

Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed.

All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.

2/2

Manufactured by Secop for Danfoss - DEHC.ED.401.D6.22 / 520N1362

June 2012

Loading...