Danfoss TLES6F Data sheet

TLES6F
102G
4610
TLES6F
8277-5
DANFOSS COMPRESSORS
Barcode on white background
Yellow background
Blue stripe
Approvals
Application
R134a
SUCTION CONNECTOR
Compressors
Energy-optimized Compressor R134a 220-240V 50Hz
Data Sheet (Replaces CD.42.T4.02)
General
Code number 102G4610
Application
Application LBP
Evaporating temperature range °C -35 to -10
Voltage range V/Hz 198 - 254 /50
Motor type RSIR/RSCR
Max. ambient temperature °C 43*
Comp. cooling at ambient temp. 32°C S
38°C S
43°C S
* run capacitor 4 µF compulsory in 38°C and higher ambient temperature
Design
Displacement cm
Oil quantity cm
Maximum refrigerant charge g 400
Free gas vol. in compressor cm
Weight without electrical equipment kg 7.6
3
3
3
5.70
180
1790
S = Static cooling normally sufficient O = Oil cooling F1= Fan cooling 1.5 m/s
(compressor compartment temperature equal to ambient temperature)
F2= Fan cooling 3.0 m/s necessary
ø16
Motor
Motor size watt 120
LRA (rated after 4 sec. UL984) LST A 4.5
Cut-in current LST A 8.8
Resistance, main and start winding (25°C) 16.5/16.9
Approvals EN 60335-2-34 with Annex AA
Dimensions
ø9
170 178 186 204
C
222
176
Height mm A 173
B 169
Suction connector location/I.D. mm C 6.2 ±0.09
Process connector location/I.D. mm D 6.2 ±0.09
A
30°
B
105
Discharge connector location/I.D. mm E 5.0 +0.12/+0.20
Compressors on a pallet pcs. 125
157
60.5 66
August 2001 CD.42.T5.02 1
45
°
102 96
20°
117
51°
35
105
8244
70
100
D
E
31.5
28°
°
107
29
71
Capacity (EN 12900/CECOMAF) watt
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material.Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
C°\.pmoC53-03-52-3.32-02-51-01-
F6SELT8577401511931381532
Capacity (ASHRAE) watt
C°\.pmoC53-03-52-3.32-02-51-01-
F6SELT1759821241271622092
Power consumption watt
C°\.pmoC53-03-52-3.32-02-51-01-
F6SELT6739211811131151271
Current consumption A
C°\.pmoC53-03-52-3.32-02-51-01-
F6SELT36.096.057.077.028.098.079.0
COP (EN 12900/CECOMAF) W/W
C°\.pmoC53-03-52-3.32-02-51-01-
F6SELT67.028.039.079.060.112.173.1
COP (ASHRAE) W/W
C°\.pmoC53-03-52-3.32-02-51-01-
F6SELT49.010.141.102.113.194.196.1
Test conditions EN 12900/CECOMAF ASHRAE Condensing temperature 55°C55°C Ambient and suction gas temp. 32°C32°C Liquid temperature 55°C32°C Static cooling, 220V 50Hz, PTC consumption incl.
(pos.1)
g
b
Main winding
Winding protector
g
8217
a1
d
Start winding
a1
N
N
L
C
e
Accessories
seciveD.giFF6SELT
revoCb0102N301
sedapsmm3.6ecivedgnitratsCTP
1a
)1.sop(
sedapsmm8.4
sedapsmm3.6ecivedgnitratsCTP
1a
2.sop(
)
sedapsmm8.4
1100N301 8100N301
6100N301 * 1200N301 *
b
Main winding
a1
d
e
N
S
feilerdroCd0101N301
4roticapacnuR µF
sedapsmm3.6
e7117-711 *
sedapsmm8.4
9117-711 *
N
L
C
CTProfneercsnoitcetorPg6740N301
seirosseccagnitnuoM
rosserpmocenoroftniojtloB seititnauqnitniojtloB seititnauqnino-panS
7191-811 8191-811 9191-811
(pos.2)
Winding protector
* run capacitor 4 µF compulsory in 38°C and higher ambient temp.
8223
a1 Start winding
2 CD.42.T5.02 August 2001
Loading...