Danfoss TLES6.5FT.3 Data sheet

TLES6.5FT.3
157
66
60.5
102 96
117
29
71
51°
20°
45°
170 178
70
100
ø16
186 204
ø9
35
105
107
105
B
A
30°
31.5°
28°
176
222
C
D
E
8244
Energy-optimized Tropical Compressor R134a 220-240V 50/60Hz
General
Code number 102G4703
Approvals
Application
Application LBP
Frequency Hz 50 60
Evaporating temperature °C -35 to -10 -35 to -10
Voltage range V 187 - 254 198 - 254
Max. condensing temperature continuous (short) °C 60 (70) 60 (70)
Max. winding temperature continuous (short) °C 125 (135) 125 (135)
Cooling requirements
Frequency Hz 50 60
Application
LBP MBP HBP LBP MBP HBP
32°C S S
38°C S S
43°C S S
Remarks on application: Run capacitor 4 µF strongly recommended at 60Hz LST.
S = Static cooling normally sufficient O = Oil cooling F1 = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) F2 = Fan cooling 3.0 m/s necessary SG = Suction gas cooling normally sufficent – = not applicable in this area
Motor
Motor type RSIR/RSCR/CSIR
LRA (rated after 4 sec. UL984), HST | LST A 8.9 7.6
Cut in Current, HST | LST A 8.9 11.0
Resistance, main | start winding (25°C) 9.7 25.0
Design
Displacement cm
Oil quantity (type) cm
3
3
6.49
180 (polyolester)
Maximum refrigerant charge g 400
Free gas volume in compressor cm
Weight without electrical equipment kg 8.3
3
1790
Dimensions
Height mm A 173
material | comment Cu-plated steel | Al caps
material | comment Cu-plated steel | Al caps
material | comment Cu-plated steel | Al caps
Suction connector location/I.D. mm | angle C 6.2 | 30°
Process connector location/I.D. mm | angle D 6.2 | 31.5°
Discharge connector location/I.D. mm | angle E 5.0 | 28°
B 169
B1
B2
Oil cooler connector location/I.D. mm | angle F
material | comment
Connector tolerance I.D. mm ±0.09, on 5.0 +0.12/+0.20
Remarks:
March 2010 DEHC.ED.404.Y1.02 1/2
8223
N
N
L
C
S
b
d
a1
e
a1
Winding protector
Start winding
Main winding
e
g
pos.2
RSCR
8217
N
N
L
C
b
d
a1
a1
Winding protector
Start winding
Main winding
g
pos.1
RSIR
8219
10
11
1312
14
b
d
a2
c
Main winding
Start winding
Winding protector
c
CSIR
EN 12900 Household (CECOMAF) 220V, 50Hz, 2W PTC consumption incl., static cooling
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 71.6 99.5 134 147 176 228 290
Power cons. in W 107 125 142 148 160 179 200
Current cons. in A 1.07 1.11 1.17 1.19 1.23 1.31 1.39
COP in W/W 0.67 0.80 0.94 0.99 1.10 1.27 1.45
EN 12900 Household (CECOMAF) 220V, 50Hz, RC 4µF, 2W PTC consumption incl., static cooling
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 71.6 99.5 134 147 176 228 290
Power cons. in W 99.5 116 133 138 149 166 186
Current cons. in A 0.69 0.74 0.80 0.82 0.87 0.94 1.03
COP in W/W 0.72 0.85 1.01 1.07 1.19 1.37 1.56
ASHRAE LBP 220V, 50Hz, 2W PTC consumption incl., static cooling
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 88.7 123 166 183 218 282 359
Power cons. in W 107 125 142 148 160 178 199
Current cons. in A 1.07 1.11 1.17 1.19 1.23 1.30 1.38
COP in W/W 0.83 0.98 1.17 1.23 1.37 1.58 1.80
EN 12900 Household (CECOMAF) 220V, 60Hz, RC 4µF, 2W PTC consumption incl., static cooling
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 84.0 117 157 173 207 267 340
Power cons. in W 113 133 151 157 170 190 212
Current cons. in A 0.58 0.65 0.73 0.76 0.82 0.93 1.05
COP in W/W 0.74 0.88 1.04 1.10 1.22 1.41 1.60
Accessories for TLES6.5FT.3 Figure Code number Test conditions EN 12900/CECOMAF ASHRAE
PTC starting device 6.3 mm spade connectors a1 103N0011 Condensing temperature 55°C 54.4°C
PTC starting device 6.3 mm spade connectors a1 103N0016 Suction gas temperature 32°C 32°C
Starting relay 6.3 mm spade connectors a2 117U6016
Start. capacitor 60 µF 6.3 mm spade connectors c 117U5014
Cover b 103N2010
Cord relief d 103N1010 Mounting accessories Code number
Run capacitor 4 µF (compulsory at 60Hz)
Protection screen for PTC g 103N0476 Snap-on in quantities Ø: 16 mm 118-1919
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2/2 DEHC.ED.404.Y1.02 March 2010
4.8 mm spade connectors (pos.1) 103N0018 Ambient temperature 32°C 32°C
4.8 mm spade connectors (pos.2) 103N0021 Liquid temperature no subcooling 32°C
6.3 mm spade connectors
4.8 mm spade connectors 117-7119 Bolt joint in quantities Ø: 16 mm 118-1918
e
117-7117 Bolt joint for one compressor Ø: 16 mm 118-1917
Loading...