Danfoss TL5G Data sheet

TL5G Universal Compressor R134a 220-240V 50/60Hz
General
Code number 102G4550
Approvals EN 60335-2-34
Application
Application LBP/HBP
Frequency Hz 50 60
Evaporating temperature °C -30 to 15 -30 to -10
Voltage range V 187 - 254 198 - 254
Max. condensing temperature continuous (short) °C 60 (70) 60 (70)
Max. winding temperature continuous (short) °C 125 (135) 125 (135)
Cooling requirements
Frequency Hz 50 60
Application
32°C S S F2S S
38°C S S F
43°C S S F
Remarks on application: HBP at 198 - 254V 50Hz only.
Motor
Motor type RSIR/CSIR
LRA (rated after 4 sec. UL984), HST | LST A 5.7 5.4
Cut in Current, HST | LST A 5.7 9.7
Resistance, main | start winding (25°C) 14.5 14.8
Design
Displacement cm
Oil quantity (type) cm
Maximum refrigerant charge g 400
Free gas volume in compressor cm
Weight without electrical equipment kg 7.5
Dimensions
Height mm A 173
Suction connector location/I.D. mm | angle C 6.2 | 30°
material | comment Cu-plated steel | Al cap
Process connector location/I.D. mm | angle D 6.2 | 31.5°
material | comment Cu-plated steel | Al cap
Discharge connector location/I.D. mm | angle E 5.0 | 28°
material | comment Cu-plated steel | Al cap
Oil cooler connector location/I.D. mm | angle F
material | comment
Connector tolerance I.D. mm ±0.09, on 5.0 +0.12/+0.20
Remarks:
LBP MBP HBP LBP MBP HBP
S S
2
S S
2
3
3
3
B 169
B1
B2
5.08
280 (polyolester)
1690
S =Staticcoolingnormallysufcient
O = Oil cooling F1 = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) F2 = Fan cooling 3.0 m/s necessary
SG =Suctiongascoolingnormallysufcent
= not applicable in this area
Dec 2011 Manufactured by Secop for Danfoss - DEHC.ED.400.C2.02 / 520N1221 1/2
EN 12900 Household (CECOMAF) 220V, 50Hz, static cooling
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 55.6 79.0 87.9 107 139 178 208 224 278 341 372 414 497
Power cons. in W 84.8 100 105 116 132 149 161 167 186 205 213 224 245
Current cons. in A 0.95 0.98 0.99 1.01 1.05 1.09 113 1.15 1.21 1.28 1.32 1.36 1.45
COP in W/W 0.66 0.79 0.83 0.92 1.05 1.19 1.29 1.34 1.50 1.67 1.74 1.84 2.03
EN 12900 Household (CECOMAF) 220V, 60Hz, static cooling
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 64.7 91.5 102 123 162 207
Power cons. in W 88.7 105.7 112.1 125 147 170
Current cons. in A 0.83 0.88 0.90 0.94 1.01 1.08
COP in W/W 0.73 0.87 0.91 0.99 1.10 1.22
ASHRAE HBP 220V, 50Hz, static cooling
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 68.6 97.5 108 132 172 220 257 277 345 423 461 514 619
Power cons. in W 84.8 100 105 116 132 149 161 167 186 205 213 224 245
Current cons. in A 0.95 0.98 0.99 1.01 1.05 1.09 113 1.15 1.21 1.28 1.32 1.36 1.45
COP in W/W 0.81 0.97 1.03 1.14 1.30 1.47 1.59 1.66 1.86 2.07 2.16 2.29 2.53
ASHRAE HBP 220V, 60Hz, static cooling
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 79.8 113 125 152 200 256
Power cons. in W 88.7 105.7 112.1 125 147 170
Current cons. in A 0.83 0.88 0.90 0.94 1.01 1.08
COP in W/W 0.90 1.07 1.12 1.22 1.36 1.51
Accessories for TL5G Figure Code number Test conditions
PTC starting device 6.3 mm spade connectors
4.8 mm spade connectors 103N0018 Ambient temperature 32°C 32°C
a1
103N0011 Condensing temperature 55°C 55°C
EN 12900/
CECOMAF
ASHRAE
HBP
Starting relay 6.3 mm spade connectors a2 117U6000 Suction gas temperature 32°C 32°C
Start. capacitor 60 µF 6.3 mm spade connectors c 117U5014 Liquid temperature 55°C 32°C
Cover b 103N2010
Cord relief d 103N1010 Mounting accessories Code number
Protection screen for PTC g 103N0476 Bolt joint for one comp. Ø: 1 6 mm 118-1917
Bolt joint in quantities Ø: 16 mm 118-1918
Snap-on in quantities Ø: 16 mm 118-1919
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to
productsalreadyonorderprovidedthatsuchalterationscanbemadewithoutsubsequentialchangesbeingnecessaryinspecicationsalreadyagreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2/2 Manufactured by Secop for Danfoss -DEHC.ED.400.C2.02 / 520N1221 Dec 2011