TL5CN
LBP/MBP Compressor
R290
220-240V 50Hz
General
Code number 102H4590
Approvals EN 60335-2-34
Compressors on pallet 125
Application
Application LBP/MBP
Frequency Hz 50 60
Evaporating temperature °C -40 to 5 –
Voltage range V 198 - 254 –
Max. condensing temperature continuous (short) °C 55 (65) –
Max. winding temperature continuous (short) °C 125 (135) –
Cooling requirements
Frequency Hz 50 60
Application
32°C F1F1– – – –
38°C F
43°C F
Remarks on application: Run capacitor 4 µF compulsory in 43°C ambient
temperature at MBP conditions.
Motor
Motor type RSIR/RSCR/CSIR
LRA (rated after 4 sec. UL984), HST | LST A 5.7 5.4
Cut in Current, HST | LST A 5.7 9.7
Resistance, main | start winding (25°C) Ω 14.5 14.8
Design
Displacement cm
Oil quantity (type) cm
Maximum refrigerant charge g 150
Free gas volume in compressor cm
Weight without electrical equipment kg 7.5
Dimensions
Height mm A 173
Suction connector location/I.D. mm | angle C 6.2 | 30°
material | comment Cu-plated steel | Al cap
Process connector location/I.D. mm | angle D 6.2 | 31.5°
material | comment Cu-plated steel | Al cap
Discharge connector location/I.D. mm | angle E 5.0 | 28°
material | comment Cu-plated steel | Al cap
Oil cooler connector location/I.D. mm | angle F –
material | comment –
Connector tolerance I.D. mm ±0.09, on 5.0 +0.12/+0.20
Remarks:
LBP MBP HBP LBP MBP HBP
1F1
1F1
3
3
3
B 169
B1 –
B2 –
– – – –
– – – –
5.08
280 (polyolester)
1690
S =Staticcoolingnormallysufcient
O = Oil cooling
F1 = Fan cooling 1.5 m/s
(compressor compartment temperature
equal to ambient temperature)
F2 = Fan cooling 3.0 m/s necessary
SG =Suctiongascoolingnormallysufcent
– = not applicable in this area
Dec 2011 Manufactured by Secop for Danfoss - DEHC.ED.540.G2.02 1/2

EN 12900 Household (CECOMAF)* 220V, 50Hz, 2 W PTC consumption incl., fan cooling F
1
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 81 109 143 183 198 230 283 345 391 416 496 586
Power cons. in W 113 130 146 162 167 178 194 211 222 228 247 266
Current cons. in A 1.00 1.04 1.09 1.14 1.16 1.19 1.25 1.32 1.36 1.39 1.46 1.54
COP in W/W 0.71 0.84 0.98 1.13 1.18 1.29 1.46 1.64 1.76 1.82 2.01 2.21
ASHRAE LBP* 220V, 50Hz, 2 W PTC consumption incl., fan cooling F
1
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 92 124 162 206 223 259 319 389 441 469 560 662
Power cons. in W 114 130 145 161 166 176 192 208 219 225 243 262
Current cons. in A 1.00 1.04 1.09 1.14 1.15 1.19 1.24 1.31 1.35 1.37 1.44 1.52
COP in W/W 0.81 0.96 1.11 1.28 1.35 1.47 1.66 1.87 2.01 2.09 2.31 2.53
Accessories for TL5CN Figure Code number Test conditions
EN 12900/
ASHRAE LBP*
CECOMAF*
PTC starting device 6.3 mm spade connectors a1 103N0011 Condensing temperature 45°C 43.3°C
4.8 mm spade connectors (pos.1) 103N0018 Ambient temperature 32°C 32°C
PTC starting device 6.3 mm spade connectors a1 103N0016 Suction gas temperature 32°C 32°C
4.8 mm spade connectors (pos.2) 103N0021 Liquid temperature no subcooling 32°C
Starting relay 6.3 mm spade connectors a2 117U7000
Start. capacitor 60 µF 6.3 mm spade connectors c 117U5014 Mounting accessories Code number
Cover b 103N2010 Bolt joint for one comp. Ø: 16 m m 118-1917
Cord relief d 103N1010 Bolt joint in quantities Ø: 1 6 mm 118-1918
Run capacitor 4 µF 6.3 mm spade connectors
(optional) 4.8 mm spade connectors 117-7119
e
117-7117 Snap-on in quantities Ø: 1 6 mm 118-1919
Protection screen for PTC g 103N0476
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to
productsalreadyonorderprovidedthatsuchalterationscanbemadewithoutsubsequentialchangesbeingnecessaryinspecicationsalreadyagreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2/2 Manufactured by Secop for Danfoss - DEHC.ED.540.G2.02 Dec 2011