Danfoss TL4.8CNX.2 LBP, TL4.8CNX.2MBP Data sheet

Danfoss TL4.8CNX.2 LBP, TL4.8CNX.2MBP Data sheet

TL4.8CNX.2 LBP/MBP Compressor R290

115V 60Hz

General

Code number

 

 

 

 

 

102H3590

 

 

Approvals

 

 

 

 

 

UL984

 

 

Compressors on pallet

 

 

 

 

 

125

 

 

Application

 

 

 

 

 

 

 

 

 

 

Application

 

 

 

 

 

LBP/MBP

 

 

Frequency

 

Hz

 

50

 

 

 

60

 

Evaporating temperature

 

°F

 

 

 

 

-40 to 45

Voltage range

 

V

 

 

 

 

95 - 135

Max. condensing temperature continuous (short)

°F

 

 

 

 

131 (149)

Max. winding temperature continuous (short)

°F

 

 

 

 

257 (275)

Cooling requirements

 

 

 

 

 

 

 

 

 

 

Frequency

 

Hz

 

50

 

 

 

60

 

Application

 

 

LBP

 

MBP

HBP

 

LBP

MBP

HBP

90°F

 

 

 

 

F2

F2

100°F

 

 

 

 

F2

F2

110°F

 

 

 

 

F2

F2

Remarks on application:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Motor

 

 

 

 

 

 

 

 

 

 

Motor type

 

 

 

 

 

CSIR

 

 

LRA (rated after 4 sec. UL984), HST | LST

A

 

18.5

 

 

 

 

Cut in Current, HST | LST

 

A

 

18.5

 

 

 

 

Resistance, main | start winding (77°F)

 

2.7

 

 

 

6.1

 

Design

 

 

 

 

 

 

 

 

 

 

Displacement

 

cu.in

 

 

 

0.292

 

 

Oil quantity (type)

 

fl.oz.

 

 

9.5 (polyolester)

 

Maximum refrigerant charge

 

oz.

 

 

 

5.3

 

 

Free gas volume in compressor

 

fl.oz.

 

 

 

54.1

 

 

Weight without electrical equipment

lbs.

 

 

 

16.5

 

 

Dimensions

 

 

 

 

 

 

 

 

 

 

Height

 

inch

A

 

 

6.81

 

 

 

 

 

B

 

 

6.65

 

 

 

 

 

B1

 

 

 

 

 

 

 

 

B2

 

 

 

 

 

Suction connector

location, I.D. in. | angle

C

0.252-0.259 | 30°

 

 

material | comment

 

Cu-plated steel | Al cap

Process connector

location, I.D. in. | angle

D

0.252-0.259 | 31.5°

 

 

material | comment

 

Cu-plated steel | Al cap

Discharge connector

location, I.D. in. | angle

E

0.189-0.193 | 28°

 

 

material | comment

 

Cu-plated steel | Al cap

Oil cooler connector

location, I.D. in. | angle

F

 

 

 

 

 

 

material | comment

 

 

 

 

 

 

Remarks:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S = Static cooling normally sufficient

O= Oil cooling

F1

= Fan cooling 1.5 m/s

 

(compressor compartment temperature

 

equal to ambient temperature)

F2

= Fan cooling 3.0 m/s necessary

SG

= Suction gas cooling normally sufficent

= not applicable in this area

August 2013

Manufactured by Secop for Danfoss - DEHC.ED.540.D2.22 / 520N1497

1/2

ASHRAE LBP

 

 

115V, 60Hz, static cooling

 

 

 

 

 

 

 

 

 

 

 

 

 

Evap. temp. in °F

-49

-40

-30

-20

-13

-10

0

10

14

20

 

30

32

40

41

45

50

59

Capacity in BTU/h

 

323

485

674

825

895

1152

1450

1582

1794

 

2189

2275

2641

2689

2889

 

 

Power cons. in W

 

136

155

175

190

196

218

240

249

262

 

283

287

302

304

311

 

 

Current cons. in A

 

2.16

2.26

2.37

2.47

2.51

2.66

2.82

2.89

2.99

 

3.15

3.18

3.31

3.32

3.38

 

 

EER in BTU/Wh

 

2.37

3.13

3.86

4.35

4.56

5.28

6.04

6.36

6.85

 

7.75

7.94

8.74

8.85

9.28

 

 

ASHRAE MBP/HBP

 

 

115V, 60Hz, static cooling

 

 

 

 

 

 

 

 

 

 

 

 

 

Evap. temp. in °F

-49

-40

-30

-20

-13

 

-10

0

10

14

20

 

30

32

40

41

45

50

59

Capacity in BTU/h

 

292

438

608

744

807

1039

1308

1426

1617

 

1973

2050

2378

2421

2601

 

 

Power cons. in W

 

136

155

175

190

196

218

240

249

262

 

283

287

302

304

311

 

 

Current cons. in A

 

2.16

2.26

2.37

2.47

2.51

2.66

2.82

2.89

2.99

 

3.15

3.18

3.31

3.32

3.38

 

 

EER in BTU/Wh

 

2.14

2.83

3.48

3.93

4.12

4.77

5.45

5.73

6.18

 

6.98

7.15

7.87

7.97

8.36

 

 

EN 12900 Household (CECOMAF)* 115V. 60Hz. static cooling

 

 

 

 

 

 

 

 

 

 

 

 

 

Evap. temp. in °F

-49

-40

-30

-20

-13

 

-10

0

10

14

20

 

30

32

40

41

45

50

59

Capacity in W

 

106

144

190

229

247

314

394

429

486

 

592

615

714

727

780

 

 

Power cons. in W

 

136

153

171

183

189

207

225

232

242

 

258

261

271

272

277

 

 

Current cons. in A

 

2.16

2.24

2.34

2.42

2.46

2.58

2.71

2.76

2.83

 

2.95

2.98

3.06

3.07

3.11

 

 

COP in W/W

 

0.78

0.94

1.12

1.25

1.31

1.52

1.75

1.85

2.01

 

2.3

2.36

2.63

2.67

2.82

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Accessories for

TL4.8CNX.2

Figure

Code number

 

 

 

 

PTC starting device

1/4 in. spade connect.

a1

 

3/16 in. spade connect.

 

 

Starting relay

1/4 in. spade connect.

a2

117U7005

Cover

 

b

103N2011

Start. capacitor 240 µF

1/4 in. spade connect.

c

117U5023

Cord relief

 

d

103N1010

Test conditions

ASHRAE

ASHRAE

EN 12900/

 

LBP

MBP/HBP

CECOMAF*

 

 

 

 

Condensing temp.

130°F

130°F

113°F

Ambient temp.

90°F

90°F

90°F

Suction gas temp.

90°F

95°F

90°F

Liquid temperature

90°F

115°F

no subcooling

Mounting accessories

 

Code number

Bolt joint for one comp.

Ø: 5/8 in.

118-1917

Bolt joint in quantities

Ø: 5/8 in.

118-1918

Snap-on in quantities

Ø: 5/8 in.

118-1919

Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed.

All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.

2/2

Manufactured by Secop for Danfoss - DEHC.ED.540.D2.22 / 520N1497

August 2013

Loading...