TL4.0CNX.2
LBP/MBP Compressor
R290
115V 60Hz
General
Code number 102H3490
Approvals UL984
Compressors on pallet 125
Application
Application LBP/MBP
Frequency Hz 50 60
Evaporating temperature °F – -40 to 45
Voltage range V – 95 - 135
Max. condensing temperature continuous (short) °F – 131 (149)
Max. winding temperature continuous (short) °F – 257 (275)
Cooling requirements
Frequency Hz 50 60
Application
90°F – – – F2F2–
100°F – – – F
110°F – – – F
Remarks on application:
Motor
Motor type CSIR
LRA (rated after 4 sec. UL984), HST | LST A 18.5 –
Cut in Current, HST | LST A 18.5 –
Resistance, main | start winding (77°F) Ω 2.7 6.1
Design
Displacement cu.in 0.29
Oil quantity (type) .oz. 9.5 (polyolester)
Maximum refrigerant charge oz. 5.3
Free gas volume in compressor .oz. 54.1
Weight without electrical equipment lbs. 16.5
Dimensions
Height inch A 6.81
Suction connector location, I.D. in. | angle C 0.252-0.259 | 30°
material | comment Cu-plated steel | Al cap
Process connector location, I.D. in. | angle D 0.252-0.259 | 31.5°
material | comment Cu-plated steel | Al cap
Discharge connector location, I.D. in. | angle E 0.189-0.193 | 28°
material | comment Cu-plated steel | Al cap
Oil cooler connector location, I.D. in. | angle F –
material | comment –
Remarks:
LBP MBP HBP LBP MBP HBP
2F2
2F2
B 6.65
B1 –
B2 –
S = Static cooling normally sufcient
O = Oil cooling
F
= Fan cooling 1.5 m/s
1
(compressor compartment temperature
equal to ambient temperature)
–
F2 = Fan cooling 3.0 m/s necessary
SG = Suction gas cooling normally sufcent
–
– = not applicable in this area
August 2013 Manufactured by Secop for Danfoss - DEHC.ED.540.C2.22 / 520N1496 1/2
ASHRAE LBP 115V, 60Hz, static cooling
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 32 40 41 45 50 59
Capacity in BTU/h 237 380 539 664 722 936 1190 1305 1492 1850 1928 2271 2086 2509
Power cons. in W 114 132 150 162 168 185 202 209 218 233 236 247 248 253
Current cons. in A 2.06 2.13 2.22 2.29 2.32 2.43 2.55 2.59 2.66 2.77 2.79 2.87 2.88 2.92
EER in BTU/Wh 2.07 2.88 3.60 4.09 4.31 5.05 5.89 6.25 6.83 7.93 8.17 9.21 8.42 9.93
ASHRAE MBP/HBP 115V, 60Hz, static cooling
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 32 40 41 45 50 59
Capacity in BTU/h 214 343 486 599 651 845 1074 1177 1345 1666 1737 2045 2086 2258
Power cons. in W 114 132 150 162 168 185 202 209 218 233 236 247 248 253
Current cons. in A 2.06 2.13 2.22 2.29 2.32 2.43 2.55 2.59 2.66 2.77 2.79 2.87 2.88 2.92
EER in BTU/Wh 1.87 2.60 3.25 3.69 3.89 4.56 5.31 5.63 6.16 7.14 7.36 8.29 8.42 8.94
EN 12900 Household (CECOMAF)* 115V, 60Hz, static cooling
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 32 40 41 45 50 59
Capacity in W 82 114 153 185 200 257 325 356 407 504 526 618 631 682
Power cons. in W 118 132 147 157 161 175 189 194 201 213 215 223 223 227
Current cons. in A 2.08 2.14 2.20 2.26 2.28 2.37 2.46 2.49 2.54 2.63 2.64 2.70 2.71 2.73
COP in W/W 0.69 0.87 1.05 1.18 1.24 1.47 1.72 1.84 2.02 2.37 2.45 2.78 2.82 3.01
Accessories for TL4.0CNX.2 Figure Code number Test conditions
PTC starting device 1/4 in. spade connect.
3/16 in. spade connect. – Ambient temp.
a1
– Condensing temp.
Starting relay 1/4 in. spade connect. a2 117U7005 Suction gas temp.
Cover b 103N2011 Liquid temperature
ASHRAE
LBP
ASHRAE
MBP/HBP
130°F 130°F
90°F 90°F
90°F 95°F
90°F 115°F
EN 12900/
CECOMAF*
113°F
90°F
90°F
no subcooling
Start. capacitor 240 µF 1/4 in. spade connect. c 117U5023
Cord relief d 103N1010 Mounting accessories Code number
Bolt joint for one comp. Ø : 5/ 8 in . 118-1917
Bolt joint in quantities Ø: 5 /8 i n. 118-1918
Snap-on in quantities Ø : 5/ 8 in . 118-1919
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products
already on order provided that such alterations can be made without subsequential changes being necessary in specications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2/2 Manufactured by Secop for Danfoss - DEHC.ED.540.C2.22 / 520N1496 August 2013