TL3G
Universal Compressor
R134a
220-240V 50/60Hz
General
Code number 102G4352
Approvals UL984
Compressors on pallet 125
Application
Application LBP/HBP
Frequency Hz 50 60
Evaporating temperature °C -30 to 15 -30 to -10
Voltage range V 187 - 254 198 - 254
Max. condensing temperature continuous (short) °C 60 (70) 60 (70)
Max. winding temperature continuous (short) °C 125 (135) 125 (135)
Cooling requirements
Frequency Hz 50 60
Application
32°C S S F2S S F
38°C S S F2S S F
43°C S S F2S S F
Remarks on application:
Motor
Motor type RSIR/CSIR
LRA (rated after 4 sec. UL984), HST | LST A 4.9 3.5
Cut in Current, HST | LST A 4.9 8.0
Resistance, main | start winding (25°C) Ω 24.3 15.5
Design
Displacement cm
Oil quantity (type) cm
Maximum refrigerant charge g 400
Free gas volume in compressor cm
Weight without electrical equipment kg 6.8
Dimensions
Height mm A 163
Suction connector location/I.D. mm | angle C 6.5 | 30°
material | comment Copper | Rubber Plug
Process connector location/I.D. mm | angle D 6.5 | 31.5°
material | comment Copper | Rubber Plug
Discharge connector location/I.D. mm | angle E 5.0 | 28°
material | comment Copper | Rubber Plug
Oil cooler connector location/I.D. mm | angle F –
material | comment –
Connector tolerance I.D. mm ±0.09, on 5.0 +0.12/+0.20
Remarks:
LBP MBP HBP LBP MBP HBP
3
3
3
B 159
B1 –
B2 –
3.13
280 (polyolester)
1500
S =Staticcoolingnormallysufcient
O = Oil cooling
F1 = Fan cooling 1.5 m/s
(compressor compartment temperature
2
equal to ambient temperature)
2
F2 = Fan cooling 3.0 m/s necessary
2
SG =Suctiongascoolingnormallysufcent
– = not applicable in this area
Dec 2011 Manufactured by Secop for Danfoss - DEHC.ED.400.J7.02 / 520N1217 1/2
EN 12900 Household (CECOMAF) 220V, 50Hz, static cooling
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 25.3 40.9 46.7 59.1 80.5 106 125 136 170 211 231 258 312
Power cons. in W 57.7 65.8 68.8 75.0 85.2 96.2 104 108 120 133 139 146 159
Current cons. in A 0.68 0.70 0.70 0.72 0.74 0.77 0.79 0.80 0.84 0.88 0.89 0.92 0.97
COP in W/W 0.44 0.62 0.68 0.79 0.95 1.10 1.20 1.26 1.42 1.59 1.67 1.77 1.96
EN 12900 Household (CECOMAF) 220V, 60Hz, static cooling
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 29.5 47.4 54.3 68.9 94.6 125
Power cons. in W 60.0 69.7 73.5 81.0 95.0 111
Current cons. in A 0.60 0.63 0.64 0.66 0.70 0.74
COP in W/W 0.49 0.68 0.74 0.85 0.99 1.13
ASHRAE LBP 220V, 50Hz, static cooling
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 31.2 50.4 57.7 72.9 99.4 131 154 168 211 262 287 321 388
Power cons. in W 57.7 65.8 68.8 75.0 85.2 96.2 104 108 120 133 139 146 159
Current cons. in A 0.68 0.70 0.70 0.72 0.74 0.77 0.79 0.80 0.84 0.88 0.89 0.92 0.97
COP in W/W 0.54 0.77 0.84 0.97 1.17 1.36 1.49 1.56 1.76 1.97 2.07 2.20 2.44
ASHRAE LBP 220V, 60Hz, static cooling
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 36.3 58.4 66.9 85.0 117 155
Power cons. in W 60.0 69.7 73.5 81.0 95.0 111
Current cons. in A 0.60 0.63 0.64 0.66 0.70 0.74
COP in W/W 0.61 0.84 0.91 1.04 1.23 1.39
Accessories for TL3G Figure Code number Test conditions
EN 12900/
ASHRAE
CECOMAF
PTC starting device 6.3 mm spade connectors
4.8 mm spade connectors 103N0018 Ambient temperature 32°C 32°C
a1
103N0011 Condensing temperature 55°C 55°C
Starting relay 6.3 mm spade connectors a2 117U6009 Suction gas temperature 32°C 32°C
Start. capacitor 60 µF 6.3 mm spade connectors c 117U5014 Liquid temperature 55°C 32°C
Cover b 103N2011
Cord relief d 103N1010 Mounting accessories Code number
Protection screen for PTC g 103N0476 Bolt joint for one comp. Ø: 1 6 mm 118-1917
Bolt joint in quantities Ø: 16 mm 118-1918
Snap-on in quantities Ø: 16 mm 118-1919
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to
productsalreadyonorderprovidedthatsuchalterationscanbemadewithoutsubsequentialchangesbeingnecessaryinspecicationsalreadyagreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2/2 Manufactured by Secop for Danfoss - DEHC.ED.400.J7.02 / 520N1217 Dec 2011