Danfoss TL3F Data sheet

TL3F Standard Compressor R134a 115V 60Hz
General
Code number 102G3300
Approvals UL984
Application
Application LBP/MBP
Frequency Hz 50 60
Evaporating temperature °F -13 to 23
Voltage range V 103 - 127
Max. condensing temperature continuous (short) °F 140 (158)
Max. winding temperature continuous (short) °F 257 (257)
Cooling requirements
Frequency Hz 50 60
Application
90°F S S
100°F S S
110°F S S
Remarks on application:
Motor
Motor type RSIR
LRA (rated after 4 sec. UL984), HST | LST A 6.0
Cut in Current, HST | LST A 15.0
Resistance, main | start winding (77°F) 6.3 4.8
Design
Displacement cu.in 0.19
Oil quantity (type) .oz. 6.1 (polyolester)
Maximum refrigerant charge oz. 14.0
Free gas volume in compressor .oz. 54.3
Weight without electrical equipment lbs. 14.7
Dimensions
Height inch A 6.42
Suction connector location, I.D. in. | angle C 0.378-0.385 | 30°
material | comment Cu-plated steel | Al cap
Process connector location, I.D. in. | angle D 0.252-0.259 | 31.5°
material | comment Cu-plated steel | Al cap
Discharge connector location, I.D. in. | angle E 0.252-0.259 | 28°
material | comment Cu-plated steel | Al cap
Oil cooler connector location, I.D. in. | angle F
material | comment
Remarks:
LBP MBP HBP LBP MBP HBP
B 6.30
B1
B2
S = Static cooling normally sufcient O = Oil cooling F
= Fan cooling 1.5 m/s
1
(compressor compartment temperature equal to ambient temperature) F2 = Fan cooling 3.0 m/s necessary SG = Suction gas cooling normally sufcent – = not applicable in this area
June 2012 Manufactured by Secop for Danfoss - DEHC.ED.401.C2.22 / 520N1358 1/2
ASHRAE LBP 115V, 60Hz, static cooling
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 40 41 45 50 59 68
Capacity in BTU/h 229 253 352 479 539 639
Power cons. in W 72.3 76.9 92.4 108 115 125
Current cons. in A 1.09 1.12 1.21 1.32 1.38 1.47
EER in BTU/Wh 3.16 3.30 3.81 4.43 4.70 5.13
EN 12900 Household (CECOMAF) 115V, 60Hz, static cooling
Evap. temp. in °F -49 -40 -30 -20 -13 -10 0 10 14 20 30 40 41 45 50 59 68
Capacity in W 184 204 283 385 433 514
Power cons. in W 72.0 76.7 92.2 108 115 125
Current cons. in A 1.09 1.11 1.21 1.32 1.38 1.47
COP in W/W 2.56 2.66 3.07 3.56 3.77 4.11
Accessories for TL3F Figure Code number Test conditions
PTC starting device 1/4 in. spade connect.
3/16 in. spade connect. 103N0023 Ambient temp. 90°F 90°F
Cover b 103N2011 Suction gas temp. 90°F 90°F
Cord relief d 103N1010 Liquid temperature 90°F no subcooling
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2/2 Manufactured by Secop for Danfoss - DEHC.ED.401.C2.22 / 520N1358 June 2012
103N0003 Condensing temp. 130°F 131°F
a1
Mounting accessories Code number
Bolt joint for one comp. Ø: 5 /8 i n. 118-1917
Bolt joint in quantities Ø: 5/8 in. 118-1918
Snap-on in quantities Ø: 5/8 in. 118-1919
ASHRAE
LBP
EN 12900/
CECOMAF
Loading...