TD 1 / TDE 1 is a thermostatic expansion valve
designed to regulate refrigerant injection into
evaporators. The injection depends on the
refrigerant superheat at the evaporator outlet,
where the bulb must be placed.
TD 1 / TDE 1 is constructed for hermetic sealed
systems and supplied as angleway and
straightway version.
OEM Applications:
• GDM (Glass Door Merchandiser)
• Commercial fridge and freezer
• Heat Pump
AI218286432213en-000801
Thermostatic expansion valve, Type TD 1 / TDE 1
Features
• Refrigerants: R134a, R1234yf, R22, R290, R404A, R407C, R452A, R454C, R455A, R513A. Other refrigerants are on
request.
• Rated capacity from 0.87 to 6.86kW / 0.25 to 1.95TR for R290.
• Stainless steel bulb and Danfoss patented bulb strap:
1.
Fast and easy to install
2.
Good temperature transfer from pipe to bulb.
• Supplied with xed superheat setting as well as adjustable straightway version for setting customization.
• Permanent lter at inlet.
• Optional bleed function.
• Compact and hermetic construction.
• Stainless steel capillary tube
1.
Flexible lightweight capillary tube, tolerates more bending for trouble-free installation and longer life.
2.
Greater resistance to vibration during operation because of low weight
• Laser welded stainless steel power element, capillary tube and bulb:
1.
optimum regulation properties
2.
long life of diaphragm
3.
high pressure strength
• MOP (Max. Operating Pressure) function is available.
TD 1 / TDE 1 valves have a xedorice assembly. Both straight way and angle way conguration are available and
the angle way version is designed with xed superheat setting only.
The valves are available with internal or external pressure equalization. External pressure equalization should always
be used on systems with liquid distributors.
The stainless steel capillary tube and bulb with Danfoss patent bulb strap give reliable connection. It gives fast and
precise reaction to temperature changes in the evaporator.
Max. bulb temperature: 120 °C / 248 °F
Max. valve housing temperature: 150 °C / 302 °F
Max. working pressure: PS/MWP = 34 bar / 500 psig
Max. test pressure: 37.5 bar / 540 psig
Capillary tube length: 0.75 m / 30 inch
Bleed: 15% or 30%
NOTE:
This product is approved for R290,R455A, R454C, R1234yf by ignition source assessment in accordance to standard
EN ISO80079-36
(1)
The rated capacity is based on
Evaporating temprature te = 5 °C/41 °F
Condensing temperature tc = 32 °C/90 °F
Liquid temperature tl = 28 °C/82 °F
Table 1: Max. operating pressure
For R455A, R454C, R1234yf, contact Danfoss for more information.
To avoid charge migration when MOP valves are used, the bulb temperature must be lower than the thermostatic
element temperature.
Valve selection based on capacity calculation
As for extended capacity calculations and valve selection based on capacities and refrigerants, please refer to
Coolselector®2. Rated and extended capacities are calculated with the Coolselector®2 calculation engine to ARI
standards with the ASEREP equations based on laboratory measurements of selected valves.
Open the Coolselector tool and select thermostatic expansion valve.
Coolselector can be downloaded from https://www.danfoss.com/en/service-and-support/downloads/dcs/
coolselector-2/
or used online on http://coolselectoronline.danfoss.com
The valve is tted with a product label (on top of the diaphragm) which holds information as follows: valve type,
rated capacity,refrigerant, evaporating temperature range, MOP point, BP(bleed port %), max. working pressure
PS/MWP and production date code.
TD 1 = internal equalization
R290 = Refrigerant
BP15=bleed port 15% (blank stand for no bleed)
–40 / +10 °C / –40 / +50 °F = Evaporating temperature range
068N5617 = Code number
PS 34 bar/MWP 500 psig = Max. Working Pressure in bar and psig
BE3921B = Production date code (BE = China, 39 = Production week, 21 = Year 2021, B = Tuesday)
As the TD 1 / TDE 1 valve is typically an OEM valve, limited code number programme has been set up.
Other code numbers are available on demand.
The valves including bulb strap are supplied in multi pack or industrial pack.
Multi pack: 20 pcs pr. full pack, min. order quantity = 1 pcs.
Industrial pack: 32 pcs pr. pack (min. ordering quantity). Please contact Danfoss.
Table 3: Range N: -40 – +10 °C / -40 – +50 °F and Range AC: -25 – +15 °C / -15 – +60 °F with MOP 20 °C / 68 °F
The rated capacity is based on: Evaporating temprature te = 5 °C / 41 °F,
Condensing temperature tc = 32 °C / 90 °F,
Refrigerant temperature ahead of valve tl = 28 °C / 82 °F
Table 4: The bulb strap can also be sold separately
The list contains all certicates, declarations, and approvals for this product type. Individual code number may have
some or all of these approvals, and certain local approvals may not appear on the list.
Some approvals may change over time. You can check the most current status at danfoss.com or contact your local
Danfoss representative if you have any questions.
Danfoss oers a wide range of support along with our products, including digital product information, software,
mobile apps, and expert guidance. See the possibilities below.
The Danfoss Product Store
The Danfoss Product Store is your one-stop shop for everything product related—no matter where
you are in the world or what area of the cooling industry you work in. Get quick access to essential
information like product specs, code numbers, technical documentation, certications, accessories,
and more.
Start browsing at store.danfoss.com.
Find technical documentation
Find the technical documentation you need to get your project up and running. Get direct access to
our ocial collection of data sheets, certicates and declarations, manuals and guides, 3D models
and drawings, case stories, brochures, and much more.
Start searching now at www.danfoss.com/en/service-and-support/documentation.
Danfoss Learning
Danfoss Learning is a free online learning platform. It features courses and materials specically
designed to help engineers, installers, service technicians, and wholesalers better understand the
products, applications, industry topics, and trends that will help you do your job better.
Create your Danfoss Learning account for free at www.danfoss.com/en/service-and-support/learning.
Get local information and support
Local Danfoss websites are the main sources for help and information about our company and
products. Find product availability, get the latest regional news, or connect with a nearby expert—all
in your own language.
Find your local Danfoss website here: www.danfoss.com/en/choose-region.
Coolselector®2 - nd the best components for you HVAC/R system
Coolselector®2 makes it easy for engineers, consultants, and designers to nd and order the best
components for refrigeration and air conditioning systems. Run calculations based on your operating
conditions and then choose the best setup for your system design.
Download Coolselector®2 for free at coolselector.danfoss.com.
Any information, including, but not limited to information on selection of product, its application or use, product design, weight, dimensions, capacity or any other
technical data in product manuals, catalogues descriptions, advertisements, etc. and whether made available in writing, orally, electronically, online or via download,
shall be considered informative, and is only binding if and to the extent, explicit reference is made in a quotation or order conrmation. Danfoss cannot accept any
responsibility for possible errors in catalogues, brochures, videos and other material. Danfoss reserves the right to alter its products without notice. This also applies to
products ordered but not delivered provided that such alterations can be made without changes to form, t or function of the product. All trademarks in this material
are property of Danfoss A/S or Danfoss group companies. Danfoss and the Danfoss logo are trademarks of Danfoss A/S. All rights reserved.