Danfoss SV04 Technical Information

Danfoss SV04 Technical Information

Shuttle Valves Technical Information

Load Shuttle Valve - Normal Direction

SV04

OPERATION

This valve senses the higher of two input

 

pressures at 1 and 3, and routes it to the

 

output 2.

 

 

 

SPECIFICATIONS

Theoretical performance

 

 

 

 

 

Pressure drop

 

 

psi

Bar

26 cSt [121 SUS] hyd.oil at 50ƱC [122 ƱF]

 

 

 

 

 

 

150

10

 

 

 

 

 

100

8

 

 

3-2

 

 

 

 

 

 

 

6

 

 

 

 

 

 

 

 

 

 

 

50

4

 

 

1-2

 

 

2

 

 

 

 

 

 

 

 

 

 

0

0

5

10

15 20

25 l/min

 

 

 

 

 

 

0

2

4

6 gal/min

DIMENSIONS

Cross-sectional view

 

 

mm [in]

 

 

 

 

 

 

22 mm

34-40 Nm [25-30 lbf*ft]

Schematic

2

1

3

Specifications

Rated pressure*

315 bar [4570 psi]

Rated flow at 7 bar

15 l/min

[100 psi]

[4 US gal/min]

Leakage

6 drops/min @

 

Rated pressure

Weight

0.07 kg [0.15 lb]

Cavity

NCS04/3

*Rated pressure based on NFPA fatigue test standard (at 1 million cycles)

M18 x 1.5

3

2

1.5

 

[0.06]

 

6.1

42.4

[0.24]

[1.67]

ORDERING

INFORMATION

1

<![if ! IE]>

<![endif]>Ø 15.0 [Ø 0.59]

<![if ! IE]>

<![endif]>Ø 21.7 [Ø 0.85]

<![if ! IE]>

<![endif]>Ø14.0 [Ø0.55]

SV04-00-V

 

 

 

 

 

 

 

 

 

 

 

 

 

Load Shuttle Valve

 

 

 

 

 

 

 

 

Seal Option

Seal Kit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Omit = Buna-N

230000160

Normal Direction

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

V = Viton

230000450

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Code

Ports & Material

Body Nomenclature

00

00 = Cartridge only

No Body

SE1/4

AL, 1/4 BSP

NCS04/3-SE-1/4

SE4S

AL, #4 SAE

NCS04/3-SE-4S

SE6S

AL, #6 SAE

NCS04/3-SE-6S

**Aluminum bodies are to be used for pressures less than 210 bar (3000 psi).

***Other housings available

BC332375309103en-000101 • February 2020