Danfoss Steel valve for convectors Data sheet

Data sheet

Steel valve for convectors

 

in one-pipe heating systems

Application

 

The steel valve is designed for welding into con-

 

 

 

vectors by the manufacturer. The complete valve

 

 

consists of a steel valve body and a large capacity

 

 

valve insert with fixed flow through the radiator.

 

 

The insert has connection for all Danfoss RA 2000

 

 

thermostatic sensors.

 

 

The flow capacity of this valve is designed for

 

 

one-pipe heating systems.

 

 

 

 

 

 

Ordering

and technical data

Part

 

 

 

 

 

 

 

 

Code no.

 

 

 

 

 

 

 

Valve insert with RA 2000 sensor connection

 

 

 

 

 

013G8680

 

 

 

 

 

 

Steel valve body, straight pattern, welding connections

 

 

 

 

013L1965

 

 

 

 

 

 

Spare part: Gland seal for valve insert, 10 pcs/pack

 

 

 

 

013L0669

 

 

 

 

 

 

 

 

Spare part: Cover cap, green

 

 

 

 

 

 

013G8469

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Type

Sensor con-

Differerential pressure 1)

Test

Work.

Max. water

 

Code no.

nection

Recomm.

Technical

pressure

pressure

temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RA-G

RA 2000

0.05 - 0.1 bar

0.15 bar

16 bar

10 bar

120˚ C

 

013G8680

 

 

 

 

 

 

 

 

 

 

1) The maximum differential pressure specified is the maximum pressure at which the valves give satisfactory regulation. As with any device which imposes a pressure drop in the system, noise may occur under certain flow/pressure conditions. To ensure quiet operation, maximum pressure drop should not exceed 0.3 to 0.35 bar. The differential pressure can be reduced by the use of the Danfoss differential pressure regulators.

 

 

 

P-band (K)

 

 

kvs

RA-G BIV 013G8680, kv-value2)

 

 

 

 

 

0.5

1.0

1.5

2.0

3.0

(m3/h at ∆p =1 bar)

 

 

0.55

1.11

1.63

2.14

3.07

4.56

 

 

 

 

 

 

 

2) The kv-value indicates the flow volume (Q) in m3/h at a given lift and a pressure drop (p) across the valve at 1 bar.

kv = Q / √∆p. The kvs-value states the flow Q at a maximum lift, i.e. at fully open valve. If a remote temperature adjuster is used, the P-band is increased by a factor of 1.1.

DKCD

VDTVR202

© Danfoss 07/2009

1

Danfoss Steel valve for convectors Data sheet

Data Sheet

Steel valve for convectors in one-pipe heating systems

 

 

Dimensions

Materials in contact with water

Valve body

Steel

 

 

Valve top

Ms 58

 

 

Valve seat

PPS

 

 

O-rings

NBR / EPDM

 

 

Valve spindle

PPS

 

 

Valve cone

NBR

 

 

Pressure pin and valve spring

Chrome steel

 

 

To avoid calcification and corrosion, it is important for the composition of the circulating water to comply with the VDI 2035 guidelines.

2

VDTVR202

© Danfoss 07/2009