Danfoss Steel Valve Installation guide

Danfoss Steel Valve Installation guide

Installation Guide

Steel Valve with Air-Vent for Convectors

1

Installation in Convector

 

 

Built-in valve, type RA-N, code no. 013G8370

 

Max.

 

70°C

 

<![if ! IE]>

<![endif]>Min. 120 mm

Lubricate valve insert by dipping in water.

Insert the built-in valve into the steel valve housing

30NM

10NM

X 12

Fasten built-in valve with a torque of 30 Nm +/- 10%. 21M spanner.

Fasten air-vent with a torque of 10 Nm +/- 10%. 13M spanner.

5. Fit protection cap. Tighten cap.

Danfoss Heating Solutions

VIFOF102

 

1

Installation Guide

Steel Valve with Air-Vent for Convectors

 

 

2

Replacement of Gland Seal

 

 

2)

1)

10 NM

Replace the gland seal, code no. 013L0669. Can be done without draining the heating system.

1) 17M spanner for fixing the setting dial, 2) 10M spanner.

Test operation of valve spindle, by pushing the pin.

Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss Heating Solutions and the Danfoss Heating Solutions logotype are trademarks of Danfoss A/S. All rights reserved.

013R9570 & VIFOF102

Produced by Danfoss Heating Solutions © 11/2012

Loading...