Product category: Energy Meters Type designation(s): SonoMeter 40
Covered by this declaration is in conformity with the following directive( s), standard(s) or other normative
document(s), provided that the product is used in accorda
[RED] – Radio Equipment Directive 2014/53/EU
Article 3.1a (LVD)
EN 61010-1:2010+A1:2019
EN 62368-1:2014
EN 62311: 2008
EN 1434-1:2015+A1:2018
EN 1434-2:2015+A1:2018
EN 1434-3:2015
EN 1434-4:2015+A1:2018
EN 1434-5:2015+A1:2019
EN 1434-6:2015+A1:2019
WELMEC 7.2:2015 - Software Guide
Noti�ied Body: Lithuanian Energy Institute, 1621, performed type approval and issued certi�icate LT-1621-MI004-047.
[RoHS] – Restriction of Hazardous Substances Directive 2011/65/EU+A:2015/863
EN IEC 63000:2018
Danfoss Energy Metering
nce with our instructions.
2
1
1, 3
4
1 For variants with Radio Module the declaration for EMC & LVD shall be ignor ed
2 For variants without Radio Module the declaration for RED shall be ignored.
3 For variants without Radio Module and without Mains power supply (24V AC /DC) the declaration for RED and LVD shall be ignored.
4 Not within MID – National Type Approval Certi�icate for cooling energy DE-21- M-PTB-0069 is issued by “Physikalisch-T
Date:
2021.09.22
Place of issue:
8811 Scheifling
Austria
Danfoss only vouches for the correctness of the English version of this declaration. In the event of the declaration being translated into any other
language, the translator concerned shall be liable for the correctness of the translation
Product category: Energy Meters Type designation(s): SonoMeter 40
Covered by this declaration is in conformity with the following directive( s), regulation(s), standard(s) or other
normative document(s), provided that the product
Radio Equipment Regulations 2017
Article 3.1a (LVD)
BS EN 61010-1:2010+A1:2019
BS EN 62368-1:2014
BS EN 62311:2008
Article 3.1b (EMC)
EN 301 489-3 V2.1.1
EN 301 489-1 V1.9.2
Article 3.2 (Radio)
EN 300 220-1 V3.1.1
EN 300 220-2 V3.1.1
Electromagnetic Compatibility Regulations 2016
BS EN 55032:2015+A11:2020
Electrical Equipment (Safety) Regulations 2016
BS EN 61010-1:2010+A1:2019
BS EN 62368-1:2014
BS EN 62311:2008
Danfoss Energy Metering
is used in accordance with our instructions.
2
1
1, 3
The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations 2012
(as amended)
BS EN IEC 63000:2018
Heat Metering and Billing Regulations 2014
Heat meter accuracy cl. 7.9:
Noti�ied Body: Lithuanian Energy Institute, 1621, performed type approval and issued certi�icate LT-1621-MI004-047.
1 For variants with Radio Module the declaration for EMC & LVD shall be ignor ed
2 For variants without Radio Module the declaration for RED shall be ignored.
3 For variants without Radio Module and without Mains power supply (24V AC /DC) the declaration for RED and LVD shal
Date:
2021.09.22
Place of issue:
8811 Scheifling
Austria
Danfoss only vouches for the correctness of the English version of this declaration. In the event of the declaration being translated into any other
language, the translator concerned shall be liable for the correctness of the translation
Samo kvalifikovano osoblje može da instalira opremu, u skladu sa zahtevima navedenim
u ovom dokumentu. Detaljnija uputstva se mogu naći na adresi www.heating.danfoss.com.
Napomena! Ovaj proizvod je odobren za temperaturu okoline između 5–55 °C, ali da bi se obezbedili
idealni uslovi za bateriju preporučuje se da se instalira Računska jedinica na maks. 45 °C. Izbegavajte
opterećenje iz cevi i opreme prilikom instalacije. Ispustite vazduh iz sistema.
1.2. Identifikacija instalacije: Instalacija cevi za povrat/dovod i smer protoka
Rotacija u osi cevi: Senzor protoka treba da bude
podešen pod uglom od 45 to 315° da bi se izbeglo
Min. 45º
Min. 45º
sakupljanje vazduha u senzoru protoka.
Uslovi na ulazu/izlazu (samo za DN65 – DN100)
Da bi se povećao učinak neophodno je da uslovi za ulazni i izlazni protok budu pravilni
pre i posle senzora protoka: 5 × DN na ulazu i 3 × DN na izlazu senzora protoka.
5 x DN3 x DN
flow
protok
1.4. Montaža i plombiranje računske jedinice
Računska jedinica kalorimetra može se ugraditi u prostorijama koje se zagrevaju, radna temperatura
okoline ne sme biti viša od 55 °C. Ne sme se izlagati direktnom sunčevom svetlu.
Računska jedinica je montirana na pomoćni držač (može se usmeriti u željenom pravcu pod uglovima
od po 90°:
Mogući načini montaže računske jedinice (pomoćni držač):
– Direktna montaža na kućište senzora protoka, okretanjem za svakih 90°