Danfoss SonoMeter 40 Installation guide [sr]

Vodič za instalaciju
SonoMeter 40
Ultrazvučno merilo energije za aplikacije grejanja i hlađenja
www.danfoss.com
This doc. is managed by 500B0577
1
of
2
Vodič za instalaciju SonoMeter 40
EU DECLARATION OF CONFORMITY
Danfoss A/S
6430 Nordborg, Denmark | CVR nr.: 20 16 57 15 | Telephone: +45 7488 2222 | Fax: +45 7449 0949
declares under our sole responsibility that the
Product category: Energy Meters Type designation(s): SonoMeter 40
Covered by this declaration is in conformity with the following directive( s), standard(s) or other normative document(s), provided that the product is used in accorda
[RED] – Radio Equipment Directive 2014/53/EU Article 3.1a (LVD)
EN 61010-1:2010+A1:2019 EN 62368-1:2014 EN 62311: 2008
Article 3.1b (EMC)
EN 301 489-3 V2.1.1 EN 301 489-1 V1.9.2
Article 3.2 (Radio)
EN 300 220-1 V3.1.1 EN 300 220-2 V3.1.1
[EMC] – Electromagnetic Compatibility Directive 2014/30/EU
EN 55032:2015+A11:2020
[LVD] – Low Voltage Directive 2014/35/EU
EN 61010-1:2010+A1:2019 EN 62368-1:2014 EN 62311: 2008
[MID] – Measuring Instruments Directive 2014/32/EU
EN 1434-1:2015+A1:2018 EN 1434-2:2015+A1:2018 EN 1434-3:2015 EN 1434-4:2015+A1:2018EN 1434-5:2015+A1:2019 EN 1434-6:2015+A1:2019 WELMEC 7.2:2015 - Software Guide
Notiied Body: Lithuanian Energy Institute, 1621, performed type approval and issued certiicate LT-1621-MI004-047.
[RoHS] – Restriction of Hazardous Substances Directive 2011/65/EU+A:2015/863
EN IEC 63000:2018
Danfoss Energy Metering
nce with our instructions.
2
1
1, 3
4
1 For variants with Radio Module the declaration for EMC & LVD shall be ignor ed 2 For variants without Radio Module the declaration for RED shall be ignored. 3 For variants without Radio Module and without Mains power supply (24V AC /DC) the declaration for RED and LVD shall be ignored. 4 Not within MID – National Type Approval Certiicate for cooling energy DE-21- M-PTB-0069 is issued by “Physikalisch-T
Date:
2021.09.22
Place of issue:
8811 Scheifling Austria
Danfoss only vouches for the correctness of the English version of this declaration. In the event of the declaration being translated into any other language, the translator concerned shall be liable for the correctness of the translation
ID No: 014R2944
Signature:
Name: Norbert Spreitzer
Title: Product Portfolio Manager
Revision No: 01
2021.09.22
Place of issue:
1210 Ljubljana, Slovenia
Approved by
Signature:
Name: Gasper Benedik
Title: Energy Meters Director
echnische Bundesanstalt”.
Page
2 | © Danfoss | Merila energije | 2021.12 AN384648824392sr-000102
This doc. is managed by 500B0577
2
of
2
Vodič za instalaciju SonoMeter 40
UK DECLARATION OF CONFORMITY
Danfoss A/S
6430 Nordborg, Denmark | CVR nr.: 20 16 57 15 | Telephone: +45 7488 2222 | Fax: +45 7449 0949
declares under our sole responsibility that the
Product category: Energy Meters Type designation(s): SonoMeter 40
Covered by this declaration is in conformity with the following directive( s), regulation(s), standard(s) or other normative document(s), provided that the product
Radio Equipment Regulations 2017 Article 3.1a (LVD)
BS EN 61010-1:2010+A1:2019 BS EN 62368-1:2014 BS EN 62311:2008
Article 3.1b (EMC)
EN 301 489-3 V2.1.1 EN 301 489-1 V1.9.2
Article 3.2 (Radio)
EN 300 220-1 V3.1.1 EN 300 220-2 V3.1.1
Electromagnetic Compatibility Regulations 2016
BS EN 55032:2015+A11:2020
Electrical Equipment (Safety) Regulations 2016
BS EN 61010-1:2010+A1:2019 BS EN 62368-1:2014 BS EN 62311:2008
Danfoss Energy Metering
is used in accordance with our instructions.
2
1
1, 3
The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations 2012 (as amended)
BS EN IEC 63000:2018
Heat Metering and Billing Regulations 2014
Heat meter accuracy cl. 7.9:
Notiied Body: Lithuanian Energy Institute, 1621, performed type approval and issued certiicate LT-1621-MI004-047.
1 For variants with Radio Module the declaration for EMC & LVD shall be ignor ed 2 For variants without Radio Module the declaration for RED shall be ignored. 3 For variants without Radio Module and without Mains power supply (24V AC /DC) the declaration for RED and LVD shal
Date:
2021.09.22
Place of issue:
8811 Scheifling Austria
Danfoss only vouches for the correctness of the English version of this declaration. In the event of the declaration being translated into any other language, the translator concerned shall be liable for the correctness of the translation
ID No: 014R2944
Issued by Date:
Signature:
Name: Norbert Spreitzer
Title: Product Portfolio Manager
Revision No: 01
2021.09.22
Place of issue:
1210 Ljubljana, Slovenia
Approved by
Signature:
Name: Gasper Benedik
Title: Energy Meters Director
l be ignored.
Page
AN384648824392sr-000102 © Danfoss | Merila energije | 2021.12 | 3
Vodič za instalaciju SonoMeter 40
1. Instalacija
1.1. Priprema
Samo kvalifikovano osoblje može da instalira opremu, u skladu sa zahtevima navedenim u ovom dokumentu. Detaljnija uputstva se mogu naći na adresi www.heating.danfoss.com.
Napomena! Ovaj proizvod je odobren za temperaturu okoline između 5–55 °C, ali da bi se obezbedili idealni uslovi za bateriju preporučuje se da se instalira Računska jedinica na maks. 45 °C. Izbegavajte opterećenje iz cevi i opreme prilikom instalacije. Ispustite vazduh iz sistema.
1.2. Identifikacija instalacije: Instalacija cevi za povrat/dovod i smer protoka
Flow direction
Smer protoka
Instalacija cevi za povrat
Flow direction
Smer protoka
Instalacija cevi za dovod
AN384648824392sr-000102 © Danfoss | Merila energije | 2021.12 | 4
Vodič za instalaciju SonoMeter 40
1.3. Montaža senzora protoka
Položaj cevi: Bez ograničenja, ali izbegavajte
položaje u kojima se može nakupiti vazduh.
Rotacija u osi cevi: Senzor protoka treba da bude podešen pod uglom od 45 to 315° da bi se izbeglo
Min. 45º
Min. 45º
sakupljanje vazduha u senzoru protoka.
Uslovi na ulazu/izlazu (samo za DN65 – DN100) Da bi se povećao učinak neophodno je da uslovi za ulazni i izlazni protok budu pravilni pre i posle senzora protoka: 5 × DN na ulazu i 3 × DN na izlazu senzora protoka.
5 x DN 3 x DN
flow
protok
1.4. Montaža i plombiranje računske jedinice
Računska jedinica kalorimetra može se ugraditi u prostorijama koje se zagrevaju, radna temperatura okoline ne sme biti viša od 55 °C. Ne sme se izlagati direktnom sunčevom svetlu. Računska jedinica je montirana na pomoćni držač (može se usmeriti u željenom pravcu pod uglovima od po 90°:
Mogući načini montaže računske jedinice (pomoćni držač): – Direktna montaža na kućište senzora protoka, okretanjem za svakih 90°
(samo kada temperatura protoka ne prelazi 90 °C):
5 | © Danfoss | Merila energije | 2021.12 AN384648824392sr-000102