Product category: Energy Meters Type designation(s): SonoMeter 40
Covered by this declaration is in conformity with the following directive( s), standard(s) or other normative
document(s), provided that the product is used in accorda
[RED] – Radio Equipment Directive 2014/53/EU
Article 3.1a (LVD)
EN 61010-1:2010+A1:2019
EN 62368-1:2014
EN 62311: 2008
EN 1434-1:2015+A1:2018
EN 1434-2:2015+A1:2018
EN 1434-3:2015
EN 1434-4:2015+A1:2018
EN 1434-5:2015+A1:2019
EN 1434-6:2015+A1:2019
WELMEC 7.2:2015 - Software Guide
Noti�ied Body: Lithuanian Energy Institute, 1621, performed type approval and issued certi�icate LT-1621-MI004-047.
[RoHS] – Restriction of Hazardous Substances Directive 2011/65/EU+A:2015/863
EN IEC 63000:2018
Danfoss Energy Metering
nce with our instructions.
2
1
1, 3
4
1 For variants with Radio Module the declaration for EMC & LVD shall be ignor ed
2 For variants without Radio Module the declaration for RED shall be ignored.
3 For variants without Radio Module and without Mains power supply (24V AC /DC) the declaration for RED and LVD shall be ignored.
4 Not within MID – National Type Approval Certi�icate for cooling energy DE-21- M-PTB-0069 is issued by “Physikalisch-T
Date:
2021.09.22
Place of issue:
8811 Scheifling
Austria
Danfoss only vouches for the correctness of the English version of this declaration. In the event of the declaration being translated into any other
language, the translator concerned shall be liable for the correctness of the translation
Product category: Energy Meters Type designation(s): SonoMeter 40
Covered by this declaration is in conformity with the following directive( s), regulation(s), standard(s) or other
normative document(s), provided that the product
Radio Equipment Regulations 2017
Article 3.1a (LVD)
BS EN 61010-1:2010+A1:2019
BS EN 62368-1:2014
BS EN 62311:2008
Article 3.1b (EMC)
EN 301 489-3 V2.1.1
EN 301 489-1 V1.9.2
Article 3.2 (Radio)
EN 300 220-1 V3.1.1
EN 300 220-2 V3.1.1
Electromagnetic Compatibility Regulations 2016
BS EN 55032:2015+A11:2020
Electrical Equipment (Safety) Regulations 2016
BS EN 61010-1:2010+A1:2019
BS EN 62368-1:2014
BS EN 62311:2008
Danfoss Energy Metering
is used in accordance with our instructions.
2
1
1, 3
The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations 2012
(as amended)
BS EN IEC 63000:2018
Heat Metering and Billing Regulations 2014
Heat meter accuracy cl. 7.9:
Noti�ied Body: Lithuanian Energy Institute, 1621, performed type approval and issued certi�icate LT-1621-MI004-047.
1 For variants with Radio Module the declaration for EMC & LVD shall be ignor ed
2 For variants without Radio Module the declaration for RED shall be ignored.
3 For variants without Radio Module and without Mains power supply (24V AC /DC) the declaration for RED and LVD shal
Date:
2021.09.22
Place of issue:
8811 Scheifling
Austria
Danfoss only vouches for the correctness of the English version of this declaration. In the event of the declaration being translated into any other
language, the translator concerned shall be liable for the correctness of the translation
A berendezést csak szakképzett személyzet építheti be, betartva a jelen dokumentumban ismertetet
követelményeket. Részletes utasítások a www.heating.danfoss.com honlapon találhatók.
Fontos! Bár a terméket 5–55° C-os környezeti hőmérséklet-tartományban történő használatra hagyták
jóvá, az elem optimális állapotának biztosítása érdekében javasoljuk, hogy ne telepítse a kalkulátort
45° C-nál melegebb környezetbe. A beépítés során küszöbölje ki a csővezetékek és szerelvények által
átadott mechanikai terhelést. Öblítse át a rendszert.
1.2. A beépítés azonosítása: beépítés előremenő/visszatérő csővezetékbe és folyásirány
A maximális teljesítmény érdekében egyenes be- és kimeneti feltételek szükségesek az áramlásérzékelő
előtt és után: 5 × DN az áramlásérzékelő előtt és 3 × DN az áramlásérzékelő után.
5 x DN3 x DN
flow
folyik
1.4. A kalkulátor beépítése és tömítése
A hőmennyiségmérő kalkulátor fűtött helyiségbe is beépíthető, de az üzemi környezeti hőmérséklet
nem lépheti túl az 55 °C-ot. Közvetlen napfény nem érheti.
A kalkulátort egy segédtartóra kell felszerelni, amely 90°-os lépésekben a kívánt szögbe állítható:
A kalkulátor felszerelésének lehetséges módjai (segédtartó):
– Közvetlenül az áramlásérzékelőre, 90°-onkénti elforgatási lehetőséggel