Danfoss SonoMeter 40 Installation guide [hu]

Beépítési útmutató
SonoMeter 40
Ultrahangos hőmennyiségmérő fűtési és hűtési alkalmazásokhoz
www.danfoss.com
This doc. is managed by 500B0577
1
of
2
Beépítési útmutató SonoMeter 40
EU DECLARATION OF CONFORMITY
Danfoss A/S
6430 Nordborg, Denmark | CVR nr.: 20 16 57 15 | Telephone: +45 7488 2222 | Fax: +45 7449 0949
declares under our sole responsibility that the
Product category: Energy Meters Type designation(s): SonoMeter 40
Covered by this declaration is in conformity with the following directive( s), standard(s) or other normative document(s), provided that the product is used in accorda
[RED] – Radio Equipment Directive 2014/53/EU Article 3.1a (LVD)
EN 61010-1:2010+A1:2019 EN 62368-1:2014 EN 62311: 2008
Article 3.1b (EMC)
EN 301 489-3 V2.1.1 EN 301 489-1 V1.9.2
Article 3.2 (Radio)
EN 300 220-1 V3.1.1 EN 300 220-2 V3.1.1
[EMC] – Electromagnetic Compatibility Directive 2014/30/EU
EN 55032:2015+A11:2020
[LVD] – Low Voltage Directive 2014/35/EU
EN 61010-1:2010+A1:2019 EN 62368-1:2014 EN 62311: 2008
[MID] – Measuring Instruments Directive 2014/32/EU
EN 1434-1:2015+A1:2018 EN 1434-2:2015+A1:2018 EN 1434-3:2015 EN 1434-4:2015+A1:2018EN 1434-5:2015+A1:2019 EN 1434-6:2015+A1:2019 WELMEC 7.2:2015 - Software Guide
Notiied Body: Lithuanian Energy Institute, 1621, performed type approval and issued certiicate LT-1621-MI004-047.
[RoHS] – Restriction of Hazardous Substances Directive 2011/65/EU+A:2015/863
EN IEC 63000:2018
Danfoss Energy Metering
nce with our instructions.
2
1
1, 3
4
1 For variants with Radio Module the declaration for EMC & LVD shall be ignor ed 2 For variants without Radio Module the declaration for RED shall be ignored. 3 For variants without Radio Module and without Mains power supply (24V AC /DC) the declaration for RED and LVD shall be ignored. 4 Not within MID – National Type Approval Certiicate for cooling energy DE-21- M-PTB-0069 is issued by “Physikalisch-T
Date:
2021.09.22
Place of issue:
8811 Scheifling Austria
Danfoss only vouches for the correctness of the English version of this declaration. In the event of the declaration being translated into any other language, the translator concerned shall be liable for the correctness of the translation
ID No: 014R2944
Signature:
Name: Norbert Spreitzer
Title: Product Portfolio Manager
Revision No: 01
2021.09.22
Place of issue:
1210 Ljubljana, Slovenia
Approved by
Signature:
Name: Gasper Benedik
Title: Energy Meters Director
echnische Bundesanstalt”.
Page
2 | © Danfoss | Hőmennyiségmérők | 2021.11 AN384648824392hu-000102
This doc. is managed by 500B0577
2
of
2
Beépítési útmutató SonoMeter 40
UK DECLARATION OF CONFORMITY
Danfoss A/S
6430 Nordborg, Denmark | CVR nr.: 20 16 57 15 | Telephone: +45 7488 2222 | Fax: +45 7449 0949
declares under our sole responsibility that the
Product category: Energy Meters Type designation(s): SonoMeter 40
Covered by this declaration is in conformity with the following directive( s), regulation(s), standard(s) or other normative document(s), provided that the product
Radio Equipment Regulations 2017 Article 3.1a (LVD)
BS EN 61010-1:2010+A1:2019 BS EN 62368-1:2014 BS EN 62311:2008
Article 3.1b (EMC)
EN 301 489-3 V2.1.1 EN 301 489-1 V1.9.2
Article 3.2 (Radio)
EN 300 220-1 V3.1.1 EN 300 220-2 V3.1.1
Electromagnetic Compatibility Regulations 2016
BS EN 55032:2015+A11:2020
Electrical Equipment (Safety) Regulations 2016
BS EN 61010-1:2010+A1:2019 BS EN 62368-1:2014 BS EN 62311:2008
Danfoss Energy Metering
is used in accordance with our instructions.
2
1
1, 3
The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations 2012 (as amended)
BS EN IEC 63000:2018
Heat Metering and Billing Regulations 2014
Heat meter accuracy cl. 7.9:
Notiied Body: Lithuanian Energy Institute, 1621, performed type approval and issued certiicate LT-1621-MI004-047.
1 For variants with Radio Module the declaration for EMC & LVD shall be ignor ed 2 For variants without Radio Module the declaration for RED shall be ignored. 3 For variants without Radio Module and without Mains power supply (24V AC /DC) the declaration for RED and LVD shal
Date:
2021.09.22
Place of issue:
8811 Scheifling Austria
Danfoss only vouches for the correctness of the English version of this declaration. In the event of the declaration being translated into any other language, the translator concerned shall be liable for the correctness of the translation
ID No: 014R2944
Issued by Date:
Signature:
Name: Norbert Spreitzer
Title: Product Portfolio Manager
Revision No: 01
2021.09.22
Place of issue:
1210 Ljubljana, Slovenia
Approved by
Signature:
Name: Gasper Benedik
Title: Energy Meters Director
l be ignored.
Page
AN384648824392hu-000102 © Danfoss | Hőmennyiségmérők | 2021.11 | 3
Beépítési útmutató SonoMeter 40
1. Beépítés
1.1. Előkészületek
A berendezést csak szakképzett személyzet építheti be, betartva a jelen dokumentumban ismertetet követelményeket. Részletes utasítások a www.heating.danfoss.com honlapon találhatók.
Fontos! Bár a terméket 5–55° C-os környezeti hőmérséklet-tartományban történő használatra hagyták jóvá, az elem optimális állapotának biztosítása érdekében javasoljuk, hogy ne telepítse a kalkulátort 45° C-nál melegebb környezetbe. A beépítés során küszöbölje ki a csővezetékek és szerelvények által átadott mechanikai terhelést. Öblítse át a rendszert.
1.2. A beépítés azonosítása: beépítés előremenő/visszatérő csővezetékbe és folyásirány
Folyásirány
Flow direction
Beépítés visszatérő csővezetékbe
Flow direction
Folyásirány
Beépítés előremenő csővezetékbe
AN384648824392hu-000102 © Danfoss | Hőmennyiségmérők | 2021.11 | 4
Beépítési útmutató SonoMeter 40
1.3. Az áramlásérzékelő beépítése
Elhelyezés a csővezetékben:
Az egyetlen megkötés az, hogy kerülni kell az olyan helyeket, ahol levegő gyűlhet össze.
Elforgatás a csőtengelyben:
Az áramlásérzékelőnek 45–315°-os szögben kell állnia, hogy ne gyűlhessen össze levegő.
Min. 45°
Min. 45°
Bemeneti/kimeneti feltételek (csak DN 65–100 esetén)
A maximális teljesítmény érdekében egyenes be- és kimeneti feltételek szükségesek az áramlásérzékelő előtt és után: 5 × DN az áramlásérzékelő előtt és 3 × DN az áramlásérzékelő után.
5 x DN 3 x DN
flow
folyik
1.4. A kalkulátor beépítése és tömítése
A hőmennyiségmérő kalkulátor fűtött helyiségbe is beépíthető, de az üzemi környezeti hőmérséklet nem lépheti túl az 55 °C-ot. Közvetlen napfény nem érheti. A kalkulátort egy segédtartóra kell felszerelni, amely 90°-os lépésekben a kívánt szögbe állítható:
A kalkulátor felszerelésének lehetséges módjai (segédtartó): – Közvetlenül az áramlásérzékelőre, 90°-onkénti elforgatási lehetőséggel (csak ha a vízátfolyás hőmérséklete nem haladja meg a 90 °C-ot):
5 | © Danfoss | Hőmennyiségmérők | 2021.11 AN384648824392hu-000102