Product category: Energy Meters Type designation(s): SonoMeter 40
Covered by this declaration is in conformity with the following directive( s), standard(s) or other normative
document(s), provided that the product is used in accorda
[RED] – Radio Equipment Directive 2014/53/EU
Article 3.1a (LVD)
EN 61010-1:2010+A1:2019
EN 62368-1:2014
EN 62311: 2008
EN 1434-1:2015+A1:2018
EN 1434-2:2015+A1:2018
EN 1434-3:2015
EN 1434-4:2015+A1:2018
EN 1434-5:2015+A1:2019
EN 1434-6:2015+A1:2019
WELMEC 7.2:2015 - Software Guide
Noti�ied Body: Lithuanian Energy Institute, 1621, performed type approval and issued certi�icate LT-1621-MI004-047.
[RoHS] – Restriction of Hazardous Substances Directive 2011/65/EU+A:2015/863
EN IEC 63000:2018
Danfoss Energy Metering
nce with our instructions.
2
1
1, 3
4
1 For variants with Radio Module the declaration for EMC & LVD shall be ignor ed
2 For variants without Radio Module the declaration for RED shall be ignored.
3 For variants without Radio Module and without Mains power supply (24V AC /DC) the declaration for RED and LVD shall be ignored.
4 Not within MID – National Type Approval Certi�icate for cooling energy DE-21- M-PTB-0069 is issued by “Physikalisch-T
Date:
2021.09.22
Place of issue:
8811 Scheifling
Austria
Danfoss only vouches for the correctness of the English version of this declaration. In the event of the declaration being translated into any other
language, the translator concerned shall be liable for the correctness of the translation
Product category: Energy Meters Type designation(s): SonoMeter 40
Covered by this declaration is in conformity with the following directive( s), regulation(s), standard(s) or other
normative document(s), provided that the product
Radio Equipment Regulations 2017
Article 3.1a (LVD)
BS EN 61010-1:2010+A1:2019
BS EN 62368-1:2014
BS EN 62311:2008
Article 3.1b (EMC)
EN 301 489-3 V2.1.1
EN 301 489-1 V1.9.2
Article 3.2 (Radio)
EN 300 220-1 V3.1.1
EN 300 220-2 V3.1.1
Electromagnetic Compatibility Regulations 2016
BS EN 55032:2015+A11:2020
Electrical Equipment (Safety) Regulations 2016
BS EN 61010-1:2010+A1:2019
BS EN 62368-1:2014
BS EN 62311:2008
Danfoss Energy Metering
is used in accordance with our instructions.
2
1
1, 3
The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations 2012
(as amended)
BS EN IEC 63000:2018
Heat Metering and Billing Regulations 2014
Heat meter accuracy cl. 7.9:
Noti�ied Body: Lithuanian Energy Institute, 1621, performed type approval and issued certi�icate LT-1621-MI004-047.
1 For variants with Radio Module the declaration for EMC & LVD shall be ignor ed
2 For variants without Radio Module the declaration for RED shall be ignored.
3 For variants without Radio Module and without Mains power supply (24V AC /DC) the declaration for RED and LVD shal
Date:
2021.09.22
Place of issue:
8811 Scheifling
Austria
Danfoss only vouches for the correctness of the English version of this declaration. In the event of the declaration being translated into any other
language, the translator concerned shall be liable for the correctness of the translation
Niniejsze urządzenie może instalować tylko wykwalifikowany personel, postępując zgodnie z wymaganiami
przedstawionymi w niniejszym dokumencie. Więcej szczegółowych informacji można znaleźć na stronie
www.heating.danfoss.pl.
Uwaga! Ten produkt jest zatwierdzony do pracy w temperaturze otoczenia 5-55°C, jednak aby zapewnić
optymalne warunki pracy baterii, moduł licznika należy zainstalować w miejscu o maks. temperaturze 45°C.
Należy unikać naprężeń montażowych wywoływanych przez rurociągi i złączki. Przepłukać układ.
1.2. Identyfikacja miejsca montażu: montaż na rurociągu powrotnym/zasilającym
ale zalecane jest unikanie położeń mogących
powodować zapowietrzanie.
Obrót względem osi rury: Przetwornik przepływu
należy montować pod kątem od 45 do 315°,
dzięki czemu unikniemy zapowietrzania się
Min. 45°
Min. 45°
przetwornika przepływu.
Warunki dotyczące wlotu/wylotu (tylko dla DN 65-100)
W celu uzyskania maksymalnej sprawności wlot przed czujnikiem i wylot za przetwornikiem przepływu
powinny być proste na długości: 5 × DN na wlocie i 3 × DN na wylocie przetwornika przepływu.
5 x DN3 x DN
przepływ
flow
1.4. Montaż i plombowanie licznika
Przelicznik ciepłomierza można zainstalować w ogrzewanych pomieszczeniach, temperatura otoczenia
podczas pracy nie powinna przekraczać 55°C. Nie może być wystawiony na bezpośrednie działanie
promieni słonecznych.
Przelicznik jest zamontowany na dodatkowym uchwycie (można go ustawić w żądanym kierunku
pod kątem 90°:
Możliwe sposoby montażu przelicznika (dodatkowy uchwyt):
– Bezpośredni montaż na obudowie czujnika przepływu poprzez obrót o 90° (tylko gdy temperatura
zasilania nie przekracza 90°C):