EU DECLARATION OF CONFORMITY
Danfoss A/S
6430 Nordborg, Denmark | CVR nr.: 20 16 57 15 | Telephone: +45 7488 2222 | Fax: +45 7449 0949
declares under our sole responsibility that the
Product category: Energy Meters Type designation(s): SonoMeter 40
Covered by this declaration is in conformity with the following directive( s), standard(s) or other normative document(s), provided that the product is used in accorda
[RED] – Radio Equipment Directive 2014/53/EU Article 3.1a (LVD)
EN 61010-1:2010+A1:2019 EN 62368-1:2014 EN 62311: 2008
Article 3.1b (EMC)
EN 301 489-3 V2.1.1 EN 301 489-1 V1.9.2
Article 3.2 (Radio)
EN 300 220-1 V3.1.1 EN 300 220-2 V3.1.1
[EMC] – Electromagnetic Compatibility Directive 2014/30/EU
EN 55032:2015+A11:2020
[LVD] – Low Voltage Directive 2014/35/EU
EN 61010-1:2010+A1:2019 EN 62368-1:2014 EN 62311: 2008
[MID] – Measuring Instruments Directive 2014/32/EU
EN 1434-1:2015+A1:2018 EN 1434-2:2015+A1:2018 EN 1434-3:2015 EN 1434-4:2015+A1:2018EN 1434-5:2015+A1:2019 EN 1434-6:2015+A1:2019 WELMEC 7.2:2015 - Software Guide
Notiied Body: Lithuanian Energy Institute, 1621, performed type approval and issued certiicate LT-1621-MI004-047.
[RoHS] – Restriction of Hazardous Substances Directive 2011/65/EU+A:2015/863
EN IEC 63000:2018
Danfoss Energy Metering
nce with our instructions.
2
1
1, 3
4
1 For variants with Radio Module the declaration for EMC & LVD shall be ignor ed 2 For variants without Radio Module the declaration for RED shall be ignored. 3 For variants without Radio Module and without Mains power supply (24V AC /DC) the declaration for RED and LVD shall be ignored. 4 Not within MID – National Type Approval Certiicate for cooling energy DE-21- M-PTB-0069 is issued by “Physikalisch-T
Date:
2021.09.22
Place of issue:
8811 Scheifling Austria
Danfoss only vouches for the correctness of the English version of this declaration. In the event of the declaration being translated into any other language, the translator concerned shall be liable for the correctness of the translation
ID No: 014R2944
Signature:
Name: Norbert Spreitzer
Title: Product Portfolio Manager
Revision No: 01
2021.09.22
Place of issue:
1210 Ljubljana, Slovenia
Approved by
Signature:
Name: Gasper Benedik
Title: Energy Meters Director
echnische Bundesanstalt”.
Page
2 | © Danfoss | Merače energií | 2021.11 AN384648824392sk-000102
This doc. is managed by 500B0577
2
of
2
Sprievodca inštaláciou SonoMeter 40
UK DECLARATION OF CONFORMITY
Danfoss A/S
6430 Nordborg, Denmark | CVR nr.: 20 16 57 15 | Telephone: +45 7488 2222 | Fax: +45 7449 0949
declares under our sole responsibility that the
Product category: Energy Meters Type designation(s): SonoMeter 40
Covered by this declaration is in conformity with the following directive( s), regulation(s), standard(s) or other normative document(s), provided that the product
Radio Equipment Regulations 2017 Article 3.1a (LVD)
BS EN 61010-1:2010+A1:2019 BS EN 62368-1:2014 BS EN 62311:2008
Article 3.1b (EMC)
EN 301 489-3 V2.1.1 EN 301 489-1 V1.9.2
Article 3.2 (Radio)
EN 300 220-1 V3.1.1 EN 300 220-2 V3.1.1
Electromagnetic Compatibility Regulations 2016
BS EN 55032:2015+A11:2020
Electrical Equipment (Safety) Regulations 2016
BS EN 61010-1:2010+A1:2019 BS EN 62368-1:2014 BS EN 62311:2008
Danfoss Energy Metering
is used in accordance with our instructions.
2
1
1, 3
The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations 2012 (as amended)
BS EN IEC 63000:2018
Heat Metering and Billing Regulations 2014
Heat meter accuracy cl. 7.9:
Notiied Body: Lithuanian Energy Institute, 1621, performed type approval and issued certiicate LT-1621-MI004-047.
1 For variants with Radio Module the declaration for EMC & LVD shall be ignor ed 2 For variants without Radio Module the declaration for RED shall be ignored. 3 For variants without Radio Module and without Mains power supply (24V AC /DC) the declaration for RED and LVD shal
Date:
2021.09.22
Place of issue:
8811 Scheifling Austria
Danfoss only vouches for the correctness of the English version of this declaration. In the event of the declaration being translated into any other language, the translator concerned shall be liable for the correctness of the translation
ID No: 014R2944
Issued by Date:
Signature:
Name: Norbert Spreitzer
Title: Product Portfolio Manager
Revision No: 01
2021.09.22
Place of issue:
1210 Ljubljana, Slovenia
Approved by
Signature:
Name: Gasper Benedik
Title: Energy Meters Director
l be ignored.
Page
AN384648824392sk-000102 © Danfoss | Merače energií | 2021.11 | 3
Sprievodca inštaláciou SonoMeter 40
1. Inštalácia
1.1. Príprava
Inštaláciu zariadenia môže vykonávať iba kvalifikovaný personál, a to v súlade s požiadavkami uvedenými v tomto dokumente. Podrobnejší návod možno nájsť na webovej lokalite www.heating.danfoss.com.
Poznámka! Tento výrobok je schválený na prevádzku pri teplote okolia medzi 5 – 55 °C, avšak na dosiahnutie optimálnych podmienok pre batériu sa odporúča montovať počítadlo pri max. teplote 45 °C. Vyhnite sa montážnemu tlaku v potrubiach a spojkách. Systém prepláchnite.
1.2. Identifikácia inštalácie: Inštalácia vratného/prívodného potrubia a smer toku
Smer prúdenia
Flow direction
Inštalácia vratného potrubia
Flow direction
Smer prúdenia
Inštalácia prívodného potrubia
AN384648824392sk-000102 © Danfoss | Merače energií | 2021.11 | 4
Sprievodca inštaláciou SonoMeter 40
1.3. Montáž snímača prietoku
Poloha potrubia: Neexistujú obmedzenia,
ale vyhýbajte sa polohám, pri ktorých môže dôjsť k zavzdušneniu.
Rotácia na osi potrubia: Snímač prietoku by mal byť pod uhlom 45 až 315°, aby sa zabránilo zavzdušneniu snímača prietoku.
Min. 45°
Min. 45°
Vstupné/výstupné podmienky (iba pri DN 65 − 100)
Za účelom maximalizácie výkonu je potrebné, aby sa pred a za snímačom prietoku zaistili podmienky priameho prietoku na vstupe aj na výstupe: 5 × DN na vstupe a 3 × DN na výstupe snímača prietoku.
5 x DN 3 x DN
prietok
flow
1.4. Montáž a zaplombovanie počítadla
Počítadlo merača tepla možno inštalovať vo vykurovaných priestoroch, pracovná teplota okolia nesmie prekročiť 55 °C. Nesmie sa vystavovať priamemu slnečnému svetlu. Počítadlo sa montuje na pomocný držiak (môže byť orientované v požadovanom smere v uhle každých 90 °:
Možné spôsoby montáže počítadla (pomocný držiak): – Priama montáž na kryt snímača prietoku, otočenie každých 90° (len keď teplota prietoku neprekračuje 90 °C):
5 | © Danfoss | Merače energií | 2021.11 AN384648824392sk-000102
Loading...
+ 11 hidden pages