Danfoss SONO 3500CT Data sheet

Data sheet

SONO 3500CT

Ultrasonic flow meter

Description/Application

 

The SONO3500CT is an ultrasonic flow meter

 

especially designed for heating, cooling or

 

combined heating/cooling application in local

 

and district energy systems. In combination with

MID examination certificate no. :

INFOCAL 9 it becomes energy meter for heating

DK-0200-MI004-032

or cooling.

The SONO 3500CT has been approved according to MID class 2. The approved flow meter consists of a flow sensor pipe, 4 transducers with cables and a transmitter with LCD display.

Features

Ultrasonic 2-path flow sensor secures measurement and optimum accuracy

Galvanically isolated digital output for easy connection to energy calculator INFOCAL 9

115 / 230 V mains-powered with back-up battery as standard version in case of mains power failure

Optional battery-powered version (up to 6 years lifetime)

Fast measuring frequency 15 Hz / 0.5 Hz (230 V AC / Battery)

Compact (standard) or remote mounting

No pressure drop

Long-term stability

Easy one-button straight forward display

Ordering

The above codes are PN16 type of compact flow meters. The power supply is mains unit (115/230 V AC) with a 3.6 V back-up battery.

Two pulse output function included. More standard codes are available regarding nominal diameter up to DN 1200, remote version and PN25.

The standard codes are used for ordering.

Compact flow meter SONO3500CT standard codes:

DN

Qp

Qs

Pulse values

Operating

Build up code

SONO3500 Code no.

(l/p)

pressure (bar)

 

 

 

 

 

100

120

180

2.5

16

7ME3411-1RC02-3ER2

187F3530

125

200

280

2.5

16

7ME3411-1VC02-3ER2

187F3531

150

300

420

2.5

16

7ME3411-2DC02-3ER2

187F3532

200

500

700

10

16

7ME3411-2HC02-4ER2

187F3533

250

800

1120

10

16

7ME3411-2MC02-4ER2

187F3534

300

1120

1560

10

16

7ME3411-2RC02-4ER2

187F3535

350

1500

2100

10

16

7ME3411-2VC02-4ER2

187F3536

400

1900

2660

50

16

7ME3411-3DC02-5ER2

187F3537

500

2950

4130

50

16

7ME3411-3MC02-5ER2

187F3538

600

4300

6020

100

16

7ME3411-3VC02-6ER2

187F3539

700

5800

8120

100

16

7ME3411-4HC02-6ER2

187F3540

800

7600

10640

100

16

7ME3411-4RC02-6ER2

187F3541

900

10000

14000

100

16

7ME3411-5DC02-6ER2

187F3542

1000

10000

14000

100

16

7ME3411-5MC02-6ER2

187F3543

1200

10000

14000

100

16

7ME3411-5VC02-6ER2

187F3544

100

120

240

2.5

40

7ME3411-1RE02-3ER2

187F4500

125

200

400

2.5

40

7ME3411-1VE02-3ER2

187F4501

150

300

420

2.5

40

7ME3411-2DE02-3ER2

187F4502

200

500

700

10

40

7ME3411-2HE02-4ER2

187F4503

200

500

700

10

25

7ME3411-2HD02-4ER2

187F4504

250

800

1120

10

25

7ME3411-2MD02-4ER2

187F4505

300

1120

1560

10

25

7ME3411-2RD02-4ER2

187F4506

350

1500

2100

50

25

7ME3411-2VD02-4ER2

187F4507

400

1900

2660

50

25

7ME3411-3DD02-5ER2

187F4508

500

2950

4130

100

25

7ME3411-3MD02-5ER2

187F4509

600

4300

6020

100

25

7ME3411-3VD02-6ER2

187F4510

700

5800

8120

100

25

7ME3411-4HD02-6ER2

187F4511

800

7600

10640

100

25

7ME3411-4RD02-6ER2

187F4512

© Danfoss | 2021.04

AI192786473757en-000505 | 1

Danfoss SONO 3500CT Data sheet

Data sheet

SONO 3500CT

 

 

Design and function

Compact / remote version

 

The unit is available in a compact or a remote

 

version with up to 30 meter distance from flow

 

meter to transmitter. When ordering a compact

 

(standard) version the transducer cables are

 

premounted and ready for installation. Compact

 

mounting is only possible up to 120 °C. The flow

 

sensor must be isolated to protect transmitter

 

from heat. The transmitter is available in an IP67

 

enclosure.

Power supply

The standard version contains a 115 / 230 V AC mains unit including 3.6 V single battery backup in case of mains power failure. It can be retrofitted to a battery version with a dual battery pack (6 year lifetime).

Pulse output

SONO3500CT has digital output functions. Output A is MID approved and used as input for energy meter INFOCAL 9, or as input for digital systems for remote reading. Output B is preset by the factory as alarm and can’t be configured.

Items supplied

The device can be delivered as either a

 

compact or a remote system.

Compact system

Sensor

Transmitter

Operating Instruction

Calibration report

Remote system

Sensor

Transmitter

Operating Instruction

Calibration report

Wall/pipe mounting kit with bracket and terminal box

4 Transducer coaxial cables

Overview of display menu sequence

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Menu

 

 

Description

 

 

1

 

 

 

Flow volume totalizer 1 - forward

 

 

 

 

 

 

2

 

 

 

Flow volume totalizer 2 - reverse (not MID certified)

 

 

 

 

 

 

3

 

 

 

Current flow rate

 

 

 

 

 

 

4

 

 

 

Failure code F1 ... F9

 

 

 

 

 

 

5

 

 

 

Display test

 

 

 

 

 

2 | AI192786473757en-000505

© Danfoss | 2021.04

Data sheet

 

SONO 3500CT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Technical data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Diameter

Nominal

DN (mm)

 

100

125

 

150

200

250

 

300

350

 

400

 

500

600

 

700

800

900

 

1000

1200

 

Nominal

qp (m3/h)

 

120

200

 

300

500

800

 

1120

1500

 

1900

 

2950

4300

 

5800

7600

10000

 

10000

10000

 

Highest

qs (m3/h)

 

180

280

 

420

700

1120

 

1560

2100

 

2660

 

4130

6020

 

8120

10640

14000

 

14000

14000

Flow rate

operatable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ranges

Maximum

qmax (m3/h)

 

189

294

 

441

735

1176

 

1638

2205

 

2793

 

4336.5

6321

 

8526

11172

14700

 

14700

14700

 

Minimum

qi (m3/h)

 

1.2

2

 

3

5

8

 

11.2

15

 

19

 

29.5

43

 

58

76

100

 

100

200

 

Cut−off

m3/h

 

0.3

0.5

 

0.75

1.25

2

 

2.8

3.75

 

4.75

 

7.375

10.75

 

14.5

19

25

 

30

45

Operating

Maximum

PN (bar)

 

 

16/40

 

 

16/25/40

 

 

 

 

 

 

 

16/25

 

 

 

 

 

 

16

pressure

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dynamic range

qi : qp

 

 

 

 

 

 

 

 

 

1:100

 

 

 

 

 

 

 

 

 

1:50

Pulse output value

l/p

 

2.5

2.5

 

2.5

10

10

 

10

10

 

50

 

50

100

 

100

100

100

 

100

100

Pulse width

 

ms

 

 

 

 

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

 

 

Flow velocity

 

m/s

 

 

 

 

 

 

 

 

 

 

0.02 … 9

 

 

 

 

 

 

 

 

 

Measuring frequency

Hz

 

 

 

 

 

 

15 Hz (mains supply - standard) / 0.5 Hz (battery supply)

 

 

 

 

 

 

 

Mains supply

 

 

 

 

 

115 / 230 V AC, including 3.6 V single battery backup

 

 

 

 

 

 

 

(standard)

 

 

 

 

 

 

 

 

 

 

 

Power supply

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Battery

 

 

 

 

 

 

 

3.6 V battery version, incl. dual battery pack

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

supply

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Medium

 

 

 

 

 

Heating water, according to VDI-2035 (pH 8.2 - 10.5), industrial VdTÜV 1466 and AGFW FW510

 

 

Media/

Compact

°C

 

 

 

 

 

 

 

 

 

 

 

5 … 120

 

 

 

 

 

 

 

 

 

surface

(standard)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

temperature

Remote

°C

 

 

 

 

 

 

 

 

 

 

5 … 200

 

 

 

 

 

 

 

 

 

 

Environmental class

 

 

 

 

 

 

 

 

 

MID class E2 + M1

 

 

 

 

 

 

 

 

 

Protection class

 

 

 

 

 

 

IP 67 according to EN 60529 and DIN 40050 (NEMA 4X/6)

 

 

 

 

 

Basic

Storage

°C

 

 

 

 

 

 

 

 

 

 

− 40 … 85

 

 

 

 

 

 

 

 

 

features

temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ambient

°C

 

 

 

 

 

 

 

 

 

 

−10 … 55

 

 

 

 

 

 

 

 

 

 

temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pipe material

 

 

 

 

 

 

 

 

Carbon Steel EN 1.0345 / P235 GH, painted in light-gray

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Remote version cable length

 

 

 

 

 

 

5 m / 10 m / 20 m / Max. 30 m between transmitter and flow sensor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Measuring accuracy MID Class 2

© Danfoss | 2021.04

AI192786473757en-000505 | 3

Loading...