Danfoss SD 117N0001 Installation guide

Danfoss SD 117N0001 Installation guide

Technical Info

Time Delay Relay for SC-Twin

SD 117N0001, 220-240V, 50 & 60Hz

Introduction

The time delay relay type SD is designed for staggered start of two compressors in the Twinversion as the one-phase mains cannot normally be loaded with the total starting current of both compressors.

When the time delay relay is used, first one compressor is started, and about 10 seconds later the second compressor is started. This ensures the best possible characteristics and the least load on the mains.

The time delay relay has the following specification:

Technical data

Code number

117N0001

 

 

Voltage

220 - 240 V

Min. supply voltage

187 V

Max. supply voltage

255 V

Mains frequency

50 to 60 Hz

Max. operating current

7 (7) A

Max. starting current

25 A for 4 seconds

Temperature range, operation

-10 to 55°C

Temperature range, storage

-40 to 70°C

Time delay at 25°C, 220 V

10 to 25 seconds

Mounting orientation

to suit installation

Life time

500.000 cycles, 50.000 hours

Enclosure

IP 20

Connection cable / spade connectors

3 x 0,75 mm2 / 6.3 mm

 

 

 

ø 3.8

 

 

 

 

SD

117N0001

 

 

 

 

 

 

<![if ! IE]>

<![endif]>35

 

<![if ! IE]>

<![endif]>73

 

220 / 240 V 50 / 60 Hz

7(7) A

 

 

 

t

10 - 25 sec.

 

 

 

<![if ! IE]>

<![endif]>550

 

Black

t

 

 

 

L

Brown

<![if ! IE]>

<![endif]>14

 

 

N

Blue

 

 

 

 

 

 

 

 

 

 

12

 

60

 

 

 

 

 

 

108

28

<![if ! IE]>

<![endif]>1903

 

 

 

 

REFRIGERATION AND AIR CONDITIONING

Wiring diagrams

 

 

 

 

 

CSIR

 

Starting relay

 

Starting capacitor

 

 

N

 

 

 

 

 

Start winding

10

11

 

10 11

 

 

 

 

Main winding

12

13

12

13

 

 

 

Blue

 

 

 

14

14

 

Winding protector

 

 

 

 

 

 

 

L

 

 

Black

 

 

 

Brown

 

 

 

Thermostat

Time delay relay

<![if ! IE]>

<![endif]>1969

 

 

 

 

 

 

 

 

Winding protector

 

Starting capacitor

CSR

 

Main winding

 

Run capacitor

 

 

Start winding

 

 

N

Starting relay

Bleeder resistance

 

 

 

 

 

 

 

 

5

2

5

2

 

 

4

1

4

1

 

 

 

 

Black

 

L

 

Brown

 

Blue

 

 

 

 

 

Thermostat

Time delay relay

 

<![if ! IE]>

<![endif]>1970

 

 

 

 

Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed.

All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.

Danfoss Compressors GmbH

Mads-Clausen-Str. 7

D-24939 Flensburg / Germany compressors.danfoss.com

DEHC.EI.200.J1.02/520N0557 Produced by Danfoss Compressors, DEHC6093, 12.2007