User Guide
What is a thermostatic radiator valve (TRV)?
TRVs sense the air temperature around them and regulate the ow
of water through the radiator which they are tted to.
They should be set at a level that gives you the room temperature
you want. These settings may have to be dierent in each room,
and you should set the TRVs to suit each room and then leave them
to do their job. As guide to the temperatures is shown on the right.
Turning a TRV to a higher setting will not make the room heat up
any faster. How quickly the room heats up depends on the boiler
size and setting, and the radiator size. Turning a TRV to a lower setting will result in the room being controlled at a lower temperature,
and saves energy.
Set and Forget
The thermostat maintains a constant temperature in your room, set
your preferred room temperature according to the thermometer
below and that’s it. The thermostat will open and close depending
on the heat demand thereby utilizing the free heat from sunlight,
appliances and people.
RTW-RA, RLV-S & RA-FN
* Frost Protection
If you leave your home for a longer period of time, you can safely
turn the thermostat to *. At this setting, the temperature will keep
the room temperature at about 7-8 0C.
Night Setback
To save energy, simply lower the room temperature at night or at
times when nobody is at home.
Cleaning
The radiator thermostat can be cleaned with mild detergents such
as dish washing liquid. Do not use scourers, alcohol, solvents or
bleaching agents as they can damage the radiator thermostat.
5
4
28°
24°
MAX.
Additional heat saves energy
Sunlight, kitchen appliances and electric light give o additional
heat. The thermostat registers such additional heat by automatically closing down. When there no longer is enough additional heat
available, the thermostat automatically opens again.
Please do not cover the thermostat!
The thermostat must be able to register the temperature of the
room. If it is covered by e.g. thick curtains or furniture, use a thermostat with remote sensor.
3
2
1
20°
16°
12°
8°
MIN.

Installation Guide
C
A
A
B
Easy Installation
Scan for video guide
Fitting valve:
(Straight or Angled) Radiators with side connection.
1 2
Separate the valve and the tail piece.
Apply the PTFE tape to the valve and
pipe
Fit the tail piece to the radiator and
tighten with a 10mm Allen key
3
Fit the valve to the pipe; tighten the
union nut with a spanner.
Now, t the valve to the tail piece and
tighten the union nuts.
4
Fit the valve position as shown, ready
to mount the sensor.

B
Fitting the lock shield
(Straight or Angled)
1 2
Separate the lock shield and the tail
piece. Apply the PTFE tape to the lock
shield and pipe
3
Fit the lock shield to the pipe; tighten
the union nut with a spanner. Next,
t the lock shield to the tail piece and
tighten the union nuts.
Fit the tail piece to the radiator and
tighten with a 10mm Allen key
4
Once installed take o the lock shield
cover.
Ensure the RLV is open using a 8mm
Allen key, then put the cover back on.

Fitting the radiator thermostat (TRV)
C
1
2
Remove cap from valve and turn sensor to
5. Make sure union nut is turned loosely
up towards the sensor body until it is only
slightly free of the lower part of the sensor
body.
3 4
Press the sensor rmly onto the valve, ensuring that the scale pointer is at top.
Whilst holding the sensor rmly on the
Set desired room temperature.
valve secure connection by turning the
union nut clock-wise by hand. Whilst still
holding the sensor rmly on the valve fully
tighten the metal union.
Removing the Sensor:
Turn the sensor to max. position 5. Turn
union nut anti-clockwise to release locking
mechanism.
HOME thermostat sets:
Danfoss A/S
Haarupvaenget 11
DK-8600 Silkeborg
Denmark
homeretail.danfoss.com
Danfoss can a ccept no respons ibility for po ssible errors i n catalogues , brochures and ot her printed mate rial. Danfoss re serves the rig ht to alter its pro ducts withou t notice. This als o applies to produ cts already o n order provide d that such altera tions
can be made w ithout subsequent ial changes being ne cessary in speci cations already a greed. All tradem arks in this material a re property of t he respective comp anies. Danfoss and th e Danfoss logoty pe are trademark s of Danfoss A/S. All ri ghts
reserved.
Radiator
Sensor (TRV)
RTW- RA
Lock Shield Valve
RLV-S Angle RA-FN Angle
RLV-S Straight RA-FN Straight
Product
Code
013G6506 3/8” (DN 10) DE Building Regulation
013G5607 3/8” (DN 10) FR Building Regulation
013G6508 1/2” ( DN 15) DE Building Regulation
013G6509 1/2” (DN 15) FR Building Regulation
013G6514 3/8” (DN 10) SE Building Regulation
013G6515 1/2” (DN 15) SE Building Regulation
013G6510 3/8” (DN 10) DE Building Regulation
013G6 511 3/8” (DN 10) FR Building Regulation
013G6512 1/2” (DN 15) DE Building Regulation
013G6513 1/2” (DN 15) FR Building Regulation
013G6516 3/8” (DN 10) SE Building Regulation
013G6517 1/2 ” (DN 15) SE Building Regulation
Pipe
size
Building Regulation
Danfoss Heating Segment VI JPM102 06/2015