Danfoss RLV-D, RLV-S Data sheet

Data Sheet
Lockshield Valve Type RLV-D & RLV-S
Application
Code Nos. and Technical Data
RLV-D with pushfit
elbow
Type RLV-D
The RLV-D is a lockshield valve designed for use in domestic heating systems and meets the requirements in BS2767-10. Fittings and valve body dimensions are identical to those of the RA­FR valve body used with the RAS-C & RAS-D radiator thermostats, allowing the installer greater freedom in terms of work flow and ease of installation. Adjustment of the lockshield for regulation and isolation is by means of a 6mm Allen key socket in the valve body which is normally covered and protected by a screw-on brass cap. RLV-D can also be used in closed comfort cooling systems, if the piping system is free of oxygen.
The push-fit fitting is suitable for 10mm copper pipes manufactured in accordance to BS 2871 part 1 / BS EN 1057: 1996 and for 10 mm polybuthelene (PB) pipes including Hep2O, Polyplumb, OsmaGold, and 10 mm cross linked
RLV-D
Pattern Type
Angled with pushfit-elbow RLV-D 10 mm pushfit 1/2" 003L020500
Angled with compression fitting
RLV-D with compression
fitting
RLV-D 15 mm 1/2" 003L020300 RLV-D 8/10 mm 1/2" 003L020400
RLV-S Straight RLV-S Angle
Polyethylene (PEX) pipes made in accordance to BS7291 part 1:1990 or part 3:1990. Always use plastic pipe inserts of the same brand as the pipe used.
Type RLV-S
The RLV-S is a lockshield valve designed for use in domestic heating systems and meets the requirements in BS2767-10. Fittings and valve body dimensions are identical to those of the RA­FN valve body used with RA 2000 radiator thermostats, allowing the installer greater freedom in terms of work flow and ease of installation. Adjustment of the lockshield for regulation and isolation is by means of a 6mm Allen key socket in the valve body which is normally covered and protected by a screw-on brass cap. RLV-S can also be used in closed comfort cooling systems, if the piping system is free of oxygen.
Connection sizes Pipe Radiator
Code no.
Danfoss Heating Solutions VD35E302 © Danfoss 11/2011 1
Data Sheet Lockshield Valve Type RLV-D & RLV-S
RLV-S
Pattern Type
RLV-S 10 3/8" 3/8" 003L012100
Angled
Straight RLV-S 10 3/8" 3/8" 003L012200
RLV-S 15 1/2" 1/2" 003L012300 RLV-S 15 15 mm 1/2" 003L012315 RLV-S 20 3/4" 3/4" 003L012500
RLV-S 15 1/2" 1/2" 003L012400 RLV-S 15 15 mm 1/2" 003L012415 RLV-S 20 3/4" 3/4" 003L012600
Connection sizes
Pipe Radiator
Code no.
Features
Accessories
Pipe connection Compression fitting RLV-D push-fit Maximum Working Pressure 10 bar 3 bar Maximum Working Temperature 120°C 92°C Valve Body Finish Nickel Plated Nickel Plated Gland Seal Type 'O' Ring 'O' Ring Supplied with LSV Cap (nickel plated brass Yes Yes Supplied with Wheelhead Cap No No
A white (RAL 9010) plastic Wheel Head and Cover Cap can be retro-fitted to the RLV-D and RLV-S valves. The Wheel Head allows manual operation
Wheel Head & Cover Cap for RLV-D & RLV-S
Description Code no. Wheel Head 003L010600 Cover Cap (50 pcs.) 003L010800
For the RLV-D push-fit version the collet cover or the collet clip provide added security against unintended pipe disconnection. Both collet
Cover and Clip for RLV-D Push-fit
Description Code no. Collect Cover for push-fit connection (10 pcs.) 013G491200 Collect Clip for push-fit connection (10 pcs.) 013G491300
of the lockshield valves. The Cover Cap provides the option of a more conventional lockshiels valve design
covers and clips give added security, but the cover also improves the neatness of the installation.
Drain-off tail piece for RLV-D
Description Code no. Drain-off tail piece 003L010500
Compression fitting for RLV-S
Description Code no. 1/2" x 8 mm copper compression fitting 013G410800 1/2" x 10 mm copper compression fitting 013G411000 1/2" x 15 mm copper compression fitting 013G411500 3/4" x 15 mm x 2.5 mm copper compression fitting for PEX plastic pipe 013G415500 3/4" x 15 mm x 2.5 mm copper compression fitting for Alupex plastic pipe 013G418500
2 VD35E302 © Danfoss 11/2011 Danfoss Heating Solutions