Danfoss Reverse Displacement Motor Data sheet

0 (0)

Data Sheet

Open Circuit Piston Motors

Reverse Displacement Motor (RDM)

For more than 40 years, Danfoss has been developing state-of-the-art components and systems for mobile machinery used in off -highway operations around the world. We have become a preferred supplier by offering the best of what really matters: the hardware inside your vehicle application.

The Reverse Displacement Motor (RDM) is designed for use in mobile open circuit applications. It offers reverse functionality without external valves, and provides system robustness with available anticavitation and shock valves. The RDM uses the existing and proven technology of the Danfoss L/K motor. These motors have been optimized with regard to options, life, package size and installed cost.

The RDM is a two-position reversing motor, with smooth, shift-on-the-go capability. The integrated proportional shifting valve uses system pressure. It allows reversing functionality without external valves and external pressure supply.

Features

 

 

 

 

Designed for Durability and Flexibility

Wide Range of Options

 

Metric O-Ring boss

Especially designed for open circuit

Fail Safe: Without control signal, the

 

SAE O-Ring boss

 

applications with a need for reverse

 

motor is biased to maximum forward

Split flange

 

functionality

 

speed

A speed sensor is available

 

 

Five displacements allow the optimum

Damped shifting from reverse to

Applications

 

selection of a hydraulic motor to fit your

forward

application

Shaft options with dust seal protector

Fan Drives with reverse functionality

Reliability - uses existing and proven

Integrated system protection - anti-

Conveyers

 

technology of Danfoss L&K motors

cavitation and shock valve

Etc.

 

 

High capacity bearings to withstand

 

 

Installation and Packaging benefits

axial fan forces

 

 

Short and compact

Complimentary to Danfoss Series 45

Comprehensive technical literature online

 

open circuit pumps with electronic

High efficiency - nine piston rotating

 

at powersolutions.danfoss.com

 

proportional control

 

groups with an 18 degree maximum

 

 

 

PLUS+1® micro controller with fan drive

 

 

 

angle

 

 

 

software available

 

 

Uses system pressure for shifting – no

 

 

This motor has the capability to be held

 

 

 

external pressure supply needed

 

 

 

at or near neutral for potential added

 

 

Integrated shifting valve enables

 

 

 

 

system power savings or faster heating

 

 

 

reversing – no external valves needed -

 

 

 

 

 

of the engine at start-up

 

 

 

less hoses - less losses - simple and

 

 

 

Variety of porting options allow for

 

 

 

clean installation

 

 

 

easier system configurations system

 

 

12 VDC and 24 VDC valves

 

 

 

 

configurations

 

 

 

 

 

 

 

 

 

 

 

 

© Danfoss | April 2016

 

 

 

L1410616 | AI00000188en-US0202 | 1

Danfoss Reverse Displacement Motor Data sheet

Data Sheet

Reverse Displacement Motor (RDM)

Technical Specifications

Parameter

 

Unit

LM25

LM30

LM35

KM38

KM45

Displacement (maximum)

cm3

25

30

35

38

45

 

 

[in3]

[1.50]

[1.83]

[2.14]

[2.32]

[2.75]

Weight

 

kg [lb]

 

 

17.5 [38.6]

 

 

 

 

 

 

 

 

 

 

Theoretical torque

 

N·m/bar

0.40 [244]

0.48 [293]

0.56 [347]

0.60 [366]

0.72 [439]

 

 

[lbf·in/1000 psi]

 

 

 

 

 

Output speed

Rated

min-1 (rpm)

3400

3500

3600

3600

3500

 

Max.

 

3950

4150

4300

4000

3900

 

 

 

 

 

 

 

 

System pressure(1)

Max.

bar [psi]

350 [5075]

350 [5075]

325 [4715]

350 [5075]

350 [5075]

Case pressure

Rated

bar [psi]

 

0.5 [7] above outlet pressure, 2 [29] absolute pressure

 

 

 

 

 

 

 

 

Max.

 

 

2 [29] above outlet pressure, 6 [87] absolute pressure

 

 

 

 

 

 

 

 

 

Voltage

 

VDC

 

 

12, 24

 

 

Current

12 VDC

mA

 

 

1500

 

 

 

24 VDC

 

 

 

750

 

 

Connector

 

-

 

DEUTSCH connector DT04-2P

 

 

 

 

 

 

 

 

 

(1) Refer to L and K Frame Variable Motors Technical Information 520L0627 for pressure definitions

Fan Drive Circuit

Microcontroller

(PLUS+1TM)

Reservoir

Filter

 

 

Temperature

Engine Control

Sensors

T1

 

 

Module (ECM)

Diesel Engine

 

 

 

T2

 

Variable Pump

 

 

(Series 45)

 

 

Reverse

T3

 

Displacement

 

 

 

Motor (RDM)

 

 

 

P108732

2 | © Danfoss | April 2016

L1410616 | AI00000188en-US0202

Loading...
+ 2 hidden pages