Danfoss RET 24, RET 24NSB, RET 24VF Installation guide

RET 24
Electronic thermostat
RET 24
RET 24NSB
RET 24VF
Certification Mark
2
6 GB - Specifi cation 7 F - Spécifi cations 8 D - Tecnishe Daten 9 ES - Especifi caciones 10 DK - Specifi cations 11 NL - Technische Specifi caties 12 GR - РспдйбгсбцЮ 13 PL - Specyfi kacja 14 LT - Specifi kacija 15 I - Specifi cazioni 16-17 GB - Mounting / F - Montage / D - Befestigung / ES - Montaje / DK - Montering / NL - Montage / GR - ЕгкбфЬуфбуз / PL - Montaż / LT - Montavimas / I - Montaggio 18-21 GB - Wiring / F- Câblage / D - Verkabelung / ES - Cableado / DK - Ledningsføring / NL - Aansluitingen / GR - УхсмЬфщуз / PL - Podłączanie przewodów / LT - Laidai / I - Cablaggio 22 GB - Mounting / F
- Montage / D - Befestigung / ES - Montaje /
DK - Montering / NL - Montage / GR - ЕгкбфЬуфбуз / PL - Montaż / LT - Montavimas / I - Montaggio 23 GB - Locking & limiting / F - Verrouillage & Limitation / D - Sperren & Begrenzen / ES - Bloquear y Limitar / DK - Lasning og begaensning / NL - Blokkeren & Begrenzen GR - БуцЬлйуз кбй ресйпсйумьт / PL - Zamknięcie i ograniczenie / LT - Blokavimas ir ribojimas / I - Bloccaggio e esclusioni
3
What is a room thermostat?
... an explanation for householders A room thermostat simply switches the heating system on and off as necessary. It works by sensing the air temperature, switching on the heating when the air temperature falls below the thermostat setting, and switching it off once this set temperature has been reached. Turning a room thermostat to a higher setting will not make the room heat up any faster. How quickly the room heats up depends on the design of the heating system, for example, the size of boiler and radiators. Neither does the setting affect how quickly the room cools down. Turning a room thermostat to a lower setting will result in the room being controlled at a lower temperature, and saves energy.
4
The heating system will not work if a timeswitch or programmer has switched it off. The way to set and use your room thermostat is to fi nd the lowest temperature setting that you are comfortable with, and then leave it alone to do its job. The best way to do this is to set the room thermostat to a low temperature – say 18°C – and then turn it up by one degree each day until you are comfortable with the temperature. You won’t have to adjust the thermostat further. Any adjustment above this setting will waste energy and cost you more money. If your heating system is a boiler with radiators, there will usually be only one room thermostat to control the whole house. But you can have different temperatures in individual rooms by installing thermostatic radiator valves (TRVs) on individual radiators. If you don’t have TRVs, you should choose a temperature that is reasonable for the whole house. If you do have TRVs, you can choose a slightly higher setting to make sure that even the coldest room is comfortable, then prevent any overheating in other rooms by adjusting the TRVs. Room thermostats need a free fl ow of air to sense the temperature, so they must not be covered by curtains or blocked by furniture. Nearby electric fi res, televisions, wall or table lamps may prevent the thermostat from working properly.
5
GB
GB
GB
Speci cation
Speci cations
Temperature range 5-30°C
Construction BS EN60730-2-9
Speci cation
Speci cation
Speci cation
Maximum Ambient Temperature 45°C
IP Rating IP20
Supply Voltage 24Vac, 50/60Hz
Switch Rating 3(1)A
Switch Type 1B
Control Pollution Situation Degree 2
Rated Impulse Voltage
Ball Pressure Test 75°C
6
2.5kV
Spéci cations
Spéci cations
Plage de températures 5-30°C
Normes de fabrication BS EN60730-2-9
Température ambiante maximale 45°C
Indice de protection IP20
Tension d’alimentation 24Vac, 50/60Hz
Caractéristique de commutateur 3(1)A
Type de commutateur 1B
F
F
F
Spéci cations
Spéci cations
Spéci cations
Etat du contrôle de pollution Degré 2
Essai à la bille
Tension assignée de tenue au choc
7
2.5kV
75°C
D
Tecnishe Daten
Technische Daten
Temperaturbereich 5-30°C
Bauart BS EN60730-2-9
Maximale Umgebungstemeratur 45°C
Schutzart IP20
Tecnishe Daten
Betriebsspannung 24Vac, 50/60Hz
Nominaler Kontaktstrom 3(1)A
Schalterart 1B
Emissionswerte Grad 2
Nennimpulsspannung
Kugeldruckprüfung 75°C
8
2.5kV