Data Sheet
RET2001OT & TPOne-OT
Electronic Room Thermostats
Application
RET2001OT
RET & TP room thermostats are used typically in
gas boiler and wall hung radiator heating systems. The RET2001OT & TPOne-OT are sophisticated room thermostat which provide modulating control of OpenTherm compatible gas boilers.
These thermostats exchange data with the boiler
they control as opposed to on/o commands. This
type of control, in addition to providing closer,
more accurate room temperature control, also
ensures that the ow temperature from the boiler
is modulated down to as low a level as prevailing
load permits. Compared to simple on/o
thermostats RET2001OT & TPOne-OT signicantly
increasing the proportion of the boiler operating
time that is spent in economic condensing mode.
These thermostats are fully compliant with the
OpenTherm communications protocol including
low load regulation.
Functions
Room Thermostat, RET2001OT
Temperature selection is digital from the setting
ring that circles the large easy to read backlit
display. RET2001OT includes a frost protection
feature as well as holiday mode with setback temperature for energy saving while you are away.
Additional features:
• Max. and min. temperature limit settings
• User selectable frost and holiday temperatures
TPOne-OT
Programmable Room Thermostat, TPOne-OT
TPOne delivers new levels of user friendly
interaction. The exible dot matrix display
uses easy read icons and text information to
provide feedback on status and settings to the
installer and user. When the display is activated
the backlight illuminates and guides are given
on what buttons will adjust temperatures or
navigate the setting menus.
The schedule setup is exible and users can
choose 24hr, 5-2day or full 7day programming
with optional 1, 2 or 3 heating periods.
Additional TPOne features include:
• Seperate user & installer setting menus
• Holiday scheduler
• Upper and lower temperature limits
• Capacitive touch button control
• Push button lock
• °C or °F Selectable display
• Audible button click (selectable)
• Frost protect temperature setting
• Clear text display (9 Languages)
• Bolier service timer
The RET & TPOne room thermostats combine
modern design with ecient heating control,
ease of operation and high quality construction
to help provide reliable home comfort.
TPOne Comfort Modes
VDSUM102
TPOne Programmable Room Thermostat
introduces the quick access Scenario interface.
To the left of the display are 4 dedicated user
buttons. As a programmable device heating is
controlled by a preset schedule but sometimes
our schedules change intermittently so we have
made it easy for the user to adapt their heating
to suit.
The Home, Away & Asleep buttons allow the user
to quickly change the current setting to either
save energy or deliver comfort when needed.
These manual overrides stay until the next
scheduled heating change so no need to
remember to switch back to automatic control.
The additional standby button also gives the
control to stop the heating completely, this
will save energy when airing the home or can
be used to switch o during Summer months
without having to change the schedule. Standby
remains until the user chooses to switch back on.
© Danfoss | ERC | 2019.05
Data Sheet RET & TP Electronic Room Thermostats
A
B
1
2
OpenTherm
connections
in boiler
External volt
free contactor
/ switch
Wires can
be crossed
OpenTherm
connections
in RET2001OT
Set-back
connections
in RET2001OT
A
B
OpenTherm
connections
in boiler
Wires can
be crossed
OpenTherm
connections
in TPOne-OT
Ordering
Technical specications
Product Typ e
Supply
voltage
Output Code no.
RET2001OT Room Thermostat 24 V DC BUS Data 087N6475
TPOne-OT
Programmable Room
Thermostat
3 V DC Data 087N7859
Feature RET2001-OT TPOne-OT
Dot Matrix LCD Display
with text menu
and capacitive touch buttons
Type
LCD backlit display
with push buttons
Setting temperature range 5 - 35°C
Operating temperature range 0 - 45°C
Fault indication Yes
LCD Backlight Yes
Output Data 24 V DC BUS
Battery Life - Min 2 years
Power Suppy 24 V DC power line from boiler
3 V DC Battery
2 x alkaline
Wiring non-polarised 2 wire bus
ErP class Class V (eciency gain 3%)
IP rating IP30 (installed)
OpenTherm software version v4.0
Low load control Yes
Approval CE marking, EN60730
Control pollution situation Degree 2
Rated impulse voltage 2.5kV
Ball hardness test 75°C
Software classication A
ErP Class
ERP Class
The products represented within this document are classied according to, and allow completion of, the Energy
Related Product (ErP) Directive System Package che and the ErP system data label. ErP Labelling obligation is
applicable from 26th September 2015.
ErP Class Product Function and ErP Description
Modulating Room Thermostat, for use with modulating heaters
An electronic room thermostat that varies the ow temperature
of the water leaving the heater dependent upon measured room
temperature deviation from room thermostat set point. Control is
achieved by modulating the output of the heater.
RE T2 001O T TPOne-OT
Wiring connections
Product
Class
V
Important - To avoid damage to Boiler and Thermostat, connect only to OpenTherm connections on
boiler, do not connect to any other power source.
Danfoss Limited
Heating Segment • heating.danfoss.co.uk • +44 (0)330 808 6888
Danfoss c an accept no respons ibility for pos sible errors in ca talogues, bro chures and other pr inted material. Da nfoss reserve s the right to alter its p roducts with out notice. This als o applies to
produc ts already on ord er provided that su ch alterations ca n be made without su bsequential cha nges being neces sary in speci cations alread y agreed.
All trade marks in this mate rial are proper ty of the respec tive companies . Danfoss and all Danf oss logotyp es are trademark s of Danfoss A/S. A ll rights reser ved.
© Danfoss | ERC | 2019.05
• E-mail: customerservice.uk@danfoss.com
AI306945861300EN-000101 | VDSUM102
Additional eciency
gain
3%