Danfoss Radiator Thermostat RA 2510 and RA 2512
Installation Guide
Fitting the snap-lock sensor
1. Prise the green protective cap off the valve.
2.Offer sensor onto valve
ensuring that scale
pointer is at top.
Removing the snap-lock sensor
2. Turn sensor to max.
1. Prise out antitheft lock
with Danfoss tool or a
small screwdriver.
setting.
3.Press the sensor firmly
onto valve until snaplock "clicks"
3. Hold outer ring whilst
turning inner ring anticlockwise to release
snap-lock mechanism.
The sensor can now be
separated from the
valve.
4. If required firmly press
anti-theft lock into inner
ring to prevent unauthorised removal
Resetting the snap-lock
4. Having removed sensor
from valve, ensure sensor is set to max.
5. Hold outer ring whilst
turning arrow mark on
inner ring towards scale
pointer until stop.
Adjusting temperature control range
T 12••3••4 5l
7,5 14 17 20 23 26 °C
Setting the upper limit:
e.g. 4 as the highest possible
temperature selection:
1. Turn the head
to position 4.
2. Pull out one limiter
tab from lower side
of head and place
in front of the
red arrow.
✳✳
✳ 12••3••4 5l
✳✳
7,5 14 17 20 23 26 °C
Setting the lower limit:
e.g. 2 as the lowest possible
temperature selection:
1. Turn the head to
position 2.
2. Pull out the other limiter
tab from lower side
of head and place
it in front of the
black arrow.