Data Sheet
Remote Control
R70 ATEX Z1 Receiver
The R70 ATEX Z1 receiver is highly customizable with
many features and mounting kits to ensure reliable
and safe operation in potentially dangerous
applications.
Features
•
Multiband radio
•
Removable EEPROM SIM module
•
STOP: PLd, Category 3 according to EN
ISO 13849-1:2016
•
29 digital outputs
Benefits
•
Highly field-customizable
•
Frequency management against
interferences
•
Easy and fast maintenance
•
Explosion proof
Explosion protection marking:
Applications
•
Explosive environments
Comprehensive technical literature is
online at www.danfoss.com
©
Danfoss | December 2021 AI293277300761en-000301 | 1

Technical data
Specification Value
Stop function (400 - 900 MHz) Cat. 3-PLd
Ingress protection IP65/NEMA4
Frequency band - ERP 433.050 to 434.040 MHz; ERP<1 mW
434.040 to 434.790 MHz; ERP<10mW
869.700 to 870.000 MHz; ERP<5 mW
902.000 to 928.000 MHz; ERP<1mW
Range Line of sight (guaranteed) 100m
AC power supply 48 - 240 Vac
DC power supply N/A
Receiver Current Consumption 700mA
Antenna External
Removable EEPROM Internal
Signaling Internal
STOP Relays 2 (6A)
Start Relay 1 (8A)
Safety Relay 1 (8A)
ON/OFF Outputs 13 (8A)
Proportional Outputs N/A
CAN Bus Protocols N/A
ON/OFF inputs N/A
Proportional inputs N/A
Response Time 100ms
Maximum Total output current 8A
Operating Temperature Range -20° C to +60° C (-4° F to +140° F)
Storage Temperature Range (24h) -25ºC to 65ºC (-13ºF to 149ºF)
Storage Temperature Range (Long Periods) -25ºC to 50ºC (-13ºF to 122ºF)
Relative Humidity max. 95% without condensation
Weight 20 Kg aprox
Dimensions 452 x 350 x 207
Cable connection N/A
Associated transmitters T70 1 ATEX, T70 2 ATEX
Additional Options
ON/OFF Outputs (Maximum) 16 (8A)
ATEX Marking
•
Ex II 2 G D
•
Ex db ia IIB + H2 T5 Gb
•
Ex ia tb IIIC T100°C Db IP65
•
T.amb: -20°C +60°C
•
INERIS 08ATEX0029X
•
IECEx INE16.0028X
•
CML 21UKEX11118X
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products
already on order provided that such alterations can be made without subsequent changes being necessary in specifications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2 | © Danfoss | December 2021 AI293277300761en-000301