Data Sheet
Remote Control
R13 ATEX Z2 Receiver
The R13 ATEX Z2 receiver is highly customizable with
many features and mounting kits to ensure reliable
and safe operation in potentially dangerous
applications.
Features
•
Multiband radio
•
Removable EEPROM SIM module
•
STOP: PLd, Category 3 according to EN
ISO 13849-1:2016
•
13 digital outputs
Benefits
•
High field customizable
•
Frequency management against
interferences
•
Easy and fast maintenance
•
Low mechanical risk
•
Low electrostatic build-up risk
Applications
•
Explosive environments
Comprehensive technical literature is
online at www.danfoss.com
©
Danfoss | December 2021 AI293279431762en-000302 | 1
Technical data
Specification Value
Stop function (400-900 MHz) Cat. 3-PLd
Ingress protection Rating IP65/NEMA4
Frequency band - ERP 433.050 to 434.040 MHz; ERP<1 mW
434.040 to 434.790 MHz; ERP<10mW
869.700 to 870.000 MHz; ERP<5 mW
902.000 to 928.000 MHz; ERP<1mW
Range Line of Sight (guaranteed) 100m
AC power supply 48-240 Vac ± 25% (80mA)
DC power supply N/A
Receiver current consumption 700mA
Antenna External/internal
Removable EEPROM Internal
Signaling Internal
STOP Output (400-900MHz) 1 (6A)
Start Output 1 (8A)
Safety Relay 1 (8A)
ON/OFF outputs 13 (8A)
Proportional outputs N/A
CAN Bus Protocols N/A
ON/OFF inputs N/A
Proportional inputs N/A
Response Time 100ms
Maximum Total output current 8A
Operating Temperature Range -20° C to +50° C (-4° F to +122° F)
Storage Temperature Range (24h) -25ºC to 55ºC (-13ºF to 167ºF)
Storage Temperature Range (Long Periods) -25ºC to 50ºC (-13ºF to 131ºF)
Relative Humidity max. 95% without condensation
Weight 1350g
Dimensions 245 x 160 x 80
Cable connection N/A
Associated transmitters T70 1 ATEX, T70 2 ATEX
ATEX Marking
•
Ex II 3 G D
•
Ex ic nA nC IIC T4 Gc
•
Ex ic tc IIIC T135°C Dc
•
T.amb: -20°C +50°C
•
INERIS 14ATEX3013X
•
IECEx INE16.0005X
•
CML 21UKEX21117X
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products
already on order provided that such alterations can be made without subsequent changes being necessary in specifications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2 | © Danfoss | December 2021 AI293279431762en-000302