PVSK module with integrated diverter valve and P-disconnect function
Contents
Introduction
Specification and code number for PVSK modules............................................................................................................. 4
Specification and code numbers for PVSK spools................................................................................................................5
Danfoss | March 2017520L0556 | BC00000104en-US0204 | 3
Technical Information
PVSK module with integrated diverter valve and P-disconnect function
Introduction
Danfoss introduces PVSK-modules with integrated diverter valve and P-disconnect function.
The module is intended for cranes, telescope lifts and other applications that have special demands on
functionality and safety.
The PVSK-module can be integrated in PVG 32 valve groups for open- as well as closed-center systems.
PVSKPVSK spool
Functions of the PVSK-module:
When the diverter valve is in neutral position, there is no pressure (only tank pressure) in the P-
•
channel of the valve group.
When the diverter valve spool is actuated in A-direction, it enables the basic modules in the PVG-
•
group to receive pump flow supply.
When the diverter valve spool is actuated in B-direction, it enables the (High Pressure Carry Over)
•
HPCO-port in the PVSK module and the P-cannel in the valve group to receive pump flow supply.
Specification and code number for PVSK modules
Specification and code number for PVSK modules
SymbolDescriptionCode no.
Open and closed center inlet with pilot supply for electrical
actuation
Max. pump pressure 350 bar [5076 psi]
Max. pump flow 120 l/min [31.7 US gal/min]
P = ¾”; HPCO = ¾”
Danfoss | March 2017520L0556 | BC00000104en-US0204 | 5
V310135.A
PT
HPCOP
PPVB
PHPCO
HPCOP
PPVBHPCO
T
T
P
T
T
P
T
T
P
Technical Information
PVSK module with integrated diverter valve and P-disconnect function
PVSK function
PVSK sectional view
As the PVSK-module is provided with pump (P) and HPCO (High Pressure Carry Over) connections, the
standard pump connection in PVP, PVPV or PVPM must be sealed with a steel plug (see example on page
6). Note that the steel plug is not included upon delivery. In neutral position, the spool in the PVSKmodule interrupts the connection from the pump to the P-channel in the valve group. This not only
ensures a low pressure (tank pressure) in the P-channel, but also a low pressure-drop in flow circulating
between pump and tank (see PVSK characteristics on page 7).
As the PVSK-module replaces endplate PVS/PVSI, the code number field (field 11) in the specification
sheet must be left open. In general, the diverter function must be specified as a working function PVB,
which means that PVE, PVSK spool and PVM must be specified separately (see PVG 32 specification sheet
Specifications on page 10).
To ensure an adequate supply to the PVE pilot reduction valve, the tank channel of PVSK includes a
backpressure valve. In open-centre systems, the pump flow must be min. 40 l/min (10.57 US gal/min) to
maintain a sufficient pressure-drop across the backpressure valve.
2800 East 13th Street
Ames, IA 50010, USA
Phone: +1 515 239 6000
Danfoss
Power Solutions Trading
(Shanghai) Co., Ltd.
Building #22, No. 1000 Jin Hai Rd
Jin Qiao, Pudong New District
Shanghai, China 201206
Phone: +86 21 3418 5200
Comatrol
www.comatrol.com
Turolla
www.turollaocg.com
Hydro-Gear
www.hydro-gear.com
Daikin-Sauer-Danfoss
www.daikin-sauer-danfoss.com
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products
already on order provided that such alterations can be made without changes being necessary in specifications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.