Data Sheet
Electrohydraulic Actuator
PVED-CX
The extensive PVG 32 product line now includes a
PVED-CX digital actuator to ensure entrance into the
SIL 2 and CANopen world.
The PVED-CX helps OEM to reach a high performance
level while facilitating compliance with the safety
demands of Machinery Directive 2006/42/EC.
Target applications are cranes, man lifts, telehandlers
and special purpose vehicles.
The CANopen protocol is designed for proportional
valve controls and can be used in any application.
Features
•
SIL 2 certified according to IEC 61508 by
TÜV Süd
•
CANopen protocol (CiA 3.01 and CiA
4.08)
•
ASSIST (Automatic System Safety
Integrity Self Test) feature for
Autonomous self-verifying safety
system
•
High precision valve control
•
Low energy consumption
Comprehensive technical literature online
at powersolutions.danfoss.com
©
Danfoss | Jul 2016 L1022909 | AI00000109en-US0202 | 1
The PVED-CX: a cornerstone in the Danfoss Safety Concept
Safety
switch
Controller
Analogue
Control
Solenoid
Valves
Main Spool
Position
sensor
Cable harness
CAN
Spool Set-point
Closed loop
feed back
LVDT out to neighbor B
LVDT in
from
neighbor A
Spool position
Solenoid valve
control
Vbat3
Vbat2 in
Vbat2 out
Pilot oil
pressure
build up
Mech linkage.
Solenoid valve
enable
V310 207.A
All our know-how is channeled into the electronic, software, and
mechanics of the PVED-CX. The PVED-CX is designed for optimum
reliability and safety – the result of an innovative and very
thorough development process.
The PVED-CX is SIL 2 certified according to IEC 61508 by TÜV Süd.
Control and safety principles for PVED-CX
The safety approach of the PVED-CX is based on self- and
neighbor-monitoring combined with the ability to shut down all
neighbor modules. Spool movement, internal electronics, and
software processes are redundantly monitored.
Our complete valve safety concept includes PVG with PVSK.
When using PVED-CX in combination with PVG with PVSK, oil flow
is controlled locally by the PVSK. Oil flow to the application can be
shut down by both PVSK and valve without influencing other
functionality on the vehicle.
PVED-CX – supporting OEMs to meet the required Performance
Level.
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products
already on order provided that such alterations can be made without changes being necessary in specifications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2 | © Danfoss | Jul 2016 L1022909 | AI00000109en-US0202