Danfoss PVED-CX Installation guide

V310115.A
Installation Guide
Cable kit for PVED-CX
110 700 8 3
JN
110 700 8 3
V310190.B
WWARNING Cable is specific designed for use with PVED-CX
WWARNING By cable handling below 0°C [32°F]avoid twisting and rough handling.
WWARNING When changing parameters or replacing cables or modules system safety can be influenced.
© Danfoss A/S, 2014-03 11070083 • Rev EB • Mar 2014 1
Always verify system after changes. Run ASSIST test to verify cable connections.
Wiring J0
Description Color
CAN-L Yellow
CAN-H Orange
Ground Brown
Vbat Red
Vbat2 Green
Voltage and power
Vbat, Vbat2, Ground
Max 36 V
Max 80 W
Ambient temperature
Use -30° +90°C [-22° +19 4° F ]
Storage -40° +100°C [-40° +212 °F ]
Version with AMP JPT connector
Grade of enclosure IP 66
Neighbor Guide
Node connector J1 J2 J3 ... Jn
Neighbor connector Jn J1 J2 ... Jn -1
Example
Node Id 20 21 22 ... 26
Neighbor node Id 26 20 21 ... 25
J0
135
Strip + Wirequard
51418
2x1.5 mm2 + 3x0.75 mm2 Roboslepp
4000±50
J1
J2
Marking Part No, + prod week-year
8x0.75 mm2 Roboslepp
JN
V310192.B
V310191.B
Vbat
Ground
CAN H
CAN L
Sp pos out
Vbat 2 out
Vbat 2 in
Vbat 3
Not connected
Sp pos in
V310 023.A
2 11070083 • Rev EB • Mar 2014 © Danfoss A/S, 2014-03
Loading...