Status Logic........................................................................................................................................................................................ 7
Configure Communication for the Function Block..............................................................................................................8
Configure Primary Communication for Function Block................................................................................................8
Configure Redundant Communication for Function Block.........................................................................................8
Pre-Made Service Screen.............................................................................................................................................................10
IEC 61508-3 Annex D Supplemental Information.............................................................................................................. 10
Before reading this manual, read and understand the safety manual of the entire library (Safety Manual
and Programmer Guide - General, document number AQ00000254).
Warning
Do not change parameters while the machine is driving. Before changing parameters bring the machine
into a safe state to prevent harm for the operator and bystanders.
Warning
Fault detection and diagnostics must be tested with the final application which is assembled from the
function blocks.
This function block configures the PVED_CLS_WAS for use with the PVED-CLS.
The inputs of the function block are formatted to a form that the PVED-CLS expects. For more
information, refer to PVED-CLS communication protocol.
Inputs
Enter the PVED_CLS_WAS function block for an overview of its signals.
To avoid compiler errors, use only the data types specified in this table.
ParameterTypeRangeUnitDescription
ParaBus————This bus contains configuration values. You can replace these values with signals
routed from the application if desired.
Loop_TmU160 to 65535msProcessing time of one program loop.
CAN.PortPort————Determines which CAN port to transmit data from. This variable can be found in
the CAN sub-bus if using the Main Template.
EnableBOOLT/F——Digital (Boolean) input signal. Used to enable or disable CAN transmission for the
block.
T: Function enabled.
F: Function disabled.
WhlAngU160 to 5000mVWheel angle sensor signal in millivolts. This voltage signal is passed along
unmodified to the PVED-CLS. The PVED-CLS performs the scaling based on the
parameters. (P3185, P3187, P3189).
0 - 99: Error condition.
100 - 4900: Valid wheel angle signal for the PVED-CLS to scale.
4901 - 5000: Error condition.
ChkptBOOLT/F——Enables advanced checkpoints with namespace for each Diag signal.
T: Include checkpoints when compiled.
F: Do not include checkpoints when compiled.
Parameters
Learn how the function block uses parameters to customize the function.
To avoid compiler errors, use only the data types specified in this table.
Bus————This bus provides diagnostic values for troubleshooting. In addition, all inputs,
U160, 0x8008——
Source address used by the message.
Default: 250
How often the message is sent.
Default: 50
T: A new request to send a message is made before the last one is sent.
F: No overrun condition.
T: The last message requested is waiting to be transmitted on the bus.
F: No message is waiting to be sent.
parameters, and output signals are contained inside of the bus.
This signal indicates if a parameter fault is declared. It is a bitwise code, so
multiple items can be reported at a time. The following status codes are provided:
0x0000: No fault.
0x8008: At least one parameter is out of range.
This signal indicates if an input fault is declared. It is a bitwise code, so multiple
items can be reported at a time. The following fault codes are provided:
0x0000: No fault.
0x8002: An input value is too high.
Diagnostic Signals
Enter the Checkpoints page on the second level of the PVED_CLS_WAS function block to access the
function block’s signals.
The page contains checkpoints on input, parameter, and output signals. Other topics in this book
describe input, parameter, and output signals.
Status Logic
This topic describes how status logic is indicated for the function block.
The status code indicates whether the parameters used in the function are within their valid range.
ConditionHexBinaryCauseResponseCorrection
*
Invalid setup.0x8008
*
Position of set bit in a 16 bit fault or status code. Bit 1 is the least significant bit. Bit 16 set to 1 indicates a standard Danfoss status code or fault code.
1000
At least one parameter is out
of range.
Message transmission is
disabled.
Correct the out of range
parameters.
Fault Logic
Fault logic can indicate problems, causes of problems, and solutions.
ConditionHex
Input value is too
high.
*
Position of set bit in a 16 bit fault or status code. Bit 1 is the least significant bit. Bit 16 set to 1 indicates a standard Danfoss status code or fault code.
The following sequence demonstrates how to setup the function block for primary or redundant
communication.
Note that you must route the Src_Addr parameter out from the Parameters page.
Configure Primary Communication for Function Block
For primary communication, set the parameter PGN_Offset to 18.
Enabling Checkpoints
Configure Redundant Communication for Function Block
For redundant communication, set the parameter PGN_Offset to 19.
Chkpt enables the checkpoints for each Diag Bus Signal.
It is pre-connected to a constant True.
Set Chkpt to False if you do not want to use the checkpoints or if you need to free up some memory. Be
aware that Fault and Status signals disappear from the service screen by setting to False.
Warning
The programmer must implement sufficient fault management and is responsible to reach the safe state
according to the safety concept for the application.
Identical Function Blocks Need Different Namespace Values to Successfully Compile
If you use the same function block more than once in an application, you must change each function
block’s namespace value to avoid compiler errors.
All function blocks contain Advanced Checkpoint with Namespace components that enable the PLUS+1
Service Tool to read block input and output values.
Some function blocks contain non-volatile memory components that store function block operating
parameters.
——Digital (Boolean) input signal. Used to enable or disable CAN transmission for the function block.
——Source address used by the message.
——PGN offset used for the message.
msHow often the message is sent out.
——This signal indicates if an input fault is declared. It’s a bitwise code, so multiple items can be reported at a time.
Wheel angle sensor signal in millivolts. This voltage signal is passed along unmodified to the PVED-CLS. The PVEDCLS performs the scaling based on the parameters. (P3185, P3187, P3189)
0 - 99: Error condition.
100 - 4900: Valid wheel angle signal for the PVED-CLS to scale.
4901 - 5000: Error condition.
This signal indicates if a parameter fault is declared. It’s a bitwise code, so multiple items can be reported at a time.
The following status codes are provided:
0x0000: No fault.
0x8008: At least one parameter is out of range.
The following fault codes are provided:
0x0000: No fault.
0x8002: An input value is too high.
IEC 61508-3 Annex D Supplemental Information
The following table provides IEC 61508-3 Annex D supplemental information.
2800 East 13th Street
Ames, IA 50010, USA
Phone: +1 515 239 6000
Danfoss
Power Solutions Trading
(Shanghai) Co., Ltd.
Building #22, No. 1000 Jin Hai Rd
Jin Qiao, Pudong New District
Shanghai, China 201206
Phone: +86 21 3418 5200
Products we offer:
Comatrol
www.comatrol.com
Turolla
www.turollaocg.com
Hydro-Gear
www.hydro-gear.com
Daikin-Sauer-Danfoss
www.daikin-sauer-danfoss.com
DCV directional control
•
valves
Electric converters
•
Electric machines
•
Electric motors
•
Hydrostatic motors
•
Hydrostatic pumps
•
Orbital motors
•
PLUS+1® controllers
•
PLUS+1® displays
•
PLUS+1® joysticks and
•
pedals
PLUS+1® operator
•
interfaces
PLUS+1® sensors
•
PLUS+1® software
•
PLUS+1® software services,
•
support and training
Position controls and
•
sensors
PVG proportional valves
•
Steering components and
•
systems
Telematics
•
Danfoss Power Solutions is a global manufacturer and supplier of high-quality hydraulic and
electric components. We specialize in providing state-of-the-art technology and solutions
that excel in the harsh operating conditions of the mobile off-highway market as well as the
marine sector. Building on our extensive applications expertise, we work closely with you to
ensure exceptional performance for a broad range of applications. We help you and other
customers around the world speed up system development, reduce costs and bring vehicles
and vessels to market faster.
Danfoss Power Solutions – your strongest partner in mobile hydraulics and mobile
electrification.
Go to www.danfoss.com for further product information.
We offer you expert worldwide support for ensuring the best possible solutions for
outstanding performance. And with an extensive network of Global Service Partners, we also
provide you with comprehensive global service for all of our components.
Local address:
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products
already on order provided that such alterations can be made without subsequent changes being necessary in specifications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.