Status Logic........................................................................................................................................................................................ 7
Configure Communication for the Function Block..............................................................................................................8
Configure Primary Communication for Function Block................................................................................................8
Configure Redundant Communication for Function Block.........................................................................................8
Pre-Made Service Screen............................................................................................................................................................... 9
IEC 61508-3 Annex D Supplemental Information.............................................................................................................. 10
Before reading this manual, read and understand the safety manual of the entire library (Safety Manual
and Programmer Guide - General, document number AQ00000254).
Warning
Do not change parameters while the machine is driving. Before changing parameters bring the machine
into a safe state to prevent harm for the operator and bystanders.
Warning
Fault detection and diagnostics must be tested with the final application which is assembled from the
function blocks.
This function block configures the PVED_CLS_Str_Fdbk for use with the PVED-CLS.
The inputs of the block are formatted to generate the message identifier that the PVED-CLS transmits.
This block receives the message and reformats the data for use in PLUS+1® GUIDE. For more information,
refer to PVED-CLS communication protocol.
Inputs
Enter the PVED_CLS_Str_Fdbk function block for an overview of its signals.
To avoid compiler errors, use only the data types specified in this table.
ParameterTypeRangeUnitDescription
ParaBus————This bus contains configuration values. You can replace these values with signals
routed from the application if desired.
CAN.PortPort————Determines which CAN port to transmit data from. This variable can be found in
the CAN sub-bus if using the Main Template.
ChkptBOOLT/F——Enables advanced checkpoints with namespace for each Diag signal.
T: Include checkpoints when compiled.
F: Do not include checkpoints when compiled.
Parameters
Learn how the function block uses parameters to customize the function.
To avoid compiler errors, use only the data types specified in this table.
Bus————This bus provides diagnostic values for troubleshooting. In addition, all
U160, 0x8008——
0.01%
10000
0.01%
10000
inputs, parameters, and output signals are contained inside of the bus.
This signal indicates if a parameter fault is declared. It is a bitwise code, so
multiple items can be reported at a time. The following status codes are
provided:
0x0000: No fault.
0x8008: At least one parameter is out of range.
Estimated electro-hydraulic flow. Negative values represent flow to the left.
Zero represents neutral. Positive values represent flow to the right.
Lock_to_Lock_NABOOLT/F——Lock to lock not available.
Lock_to_Lock_RsvdBOOLT/F——Lock to lock value is in the reserved range.
MsgTimedOut
NoMsgReceived
CRC_FailBOOLT/F——
InvalidSeqNumBOOLT/F——
UpdatedBOOLT/F——
CAN_RawDataARRAY[8}U8T/F——Data passed directly from the CAN receiver.
BOOLT/F——
BOOLT/F——
BOOLT/F——
BOOLT/F——
Estimated electro-hydraulic flow not available.
Estimated wheel angle not available.
True if the time since the last status message has exceeded the value determined
by Timeout.
T: The message has timed out, block outputs set to zero/false. NA signals set true.
F: No error.
No message has been received yet from the device.
T: No message received since power on.
F: A message has been received since power on.
Detects if the CRC in a message does not match the calculated CRC that is
performed on the data.
T: CRC mismatch.
F: No error.
On a failure, data is switched to safe values.
Detects an invalid sequence number.
T: The CAN counter value does not match the running value.
F: No error.
On a failure, data is switched to safe values.
Pulses TRUE for one loop when new data is available.
T: Received new data.
F: Did not receive new data.
Status Logic
This topic describes how status logic is indicated for the function block.
The status code indicates whether the parameters used in the function are within their valid range.
Position of set bit in a 16 bit fault or status code. Bit 1 is the least significant bit. Bit 16 set to 1 indicates a standard Danfoss status code or fault code.
Configure Communication for the Function Block
0x8008
*
1000At least one parameter is out
of range.
Status code reported.Correct the out of range
parameters.
The following sequence demonstrates how to setup the function block for primary or redundant
communication.
Note that you must route the Src_Addr parameter out from the Parameters page.
Configure Primary Communication for Function Block
For primary communication, set the parameter Src_Addr to 19.
Configure Redundant Communication for Function Block
For redundant communication, set the parameter Src_Addr to 90.
Est Whl Ang%
Lock to LockRevNumber of desired steering wheel revolutions lock to lock.
IEC 61508-3 Annex D Supplemental Information
——PGN offset used for the message.
——Source address used by the message.
msMaximum time in ms between messages before a timeout fault is triggered.
This signal indicates if a parameter fault is declared. It’s a bitwise code, so multiple items can be reported at a time.
The following status codes are provided:
0x0000: No fault.
0x8008: At least one parameter is out of range.
%Estimated Electro-Hydraulic Flow. Negative values represent flow to the left. Zero represents neutral. Positive values
represent flow to the right
Estimated Wheel Angle. Negative values represent left. Zero represents center. Positive values represent right.
The following table provides IEC 61508-3 Annex D supplemental information.
2800 East 13th Street
Ames, IA 50010, USA
Phone: +1 515 239 6000
Danfoss
Power Solutions Trading
(Shanghai) Co., Ltd.
Building #22, No. 1000 Jin Hai Rd
Jin Qiao, Pudong New District
Shanghai, China 201206
Phone: +86 21 3418 5200
Products we offer:
Comatrol
www.comatrol.com
Turolla
www.turollaocg.com
Hydro-Gear
www.hydro-gear.com
Daikin-Sauer-Danfoss
www.daikin-sauer-danfoss.com
DCV directional control
•
valves
Electric converters
•
Electric machines
•
Electric motors
•
Hydrostatic motors
•
Hydrostatic pumps
•
Orbital motors
•
PLUS+1® controllers
•
PLUS+1® displays
•
PLUS+1® joysticks and
•
pedals
PLUS+1® operator
•
interfaces
PLUS+1® sensors
•
PLUS+1® software
•
PLUS+1® software services,
•
support and training
Position controls and
•
sensors
PVG proportional valves
•
Steering components and
•
systems
Telematics
•
Danfoss Power Solutions is a global manufacturer and supplier of high-quality hydraulic and
electric components. We specialize in providing state-of-the-art technology and solutions
that excel in the harsh operating conditions of the mobile off-highway market as well as the
marine sector. Building on our extensive applications expertise, we work closely with you to
ensure exceptional performance for a broad range of applications. We help you and other
customers around the world speed up system development, reduce costs and bring vehicles
and vessels to market faster.
Danfoss Power Solutions – your strongest partner in mobile hydraulics and mobile
electrification.
Go to www.danfoss.com for further product information.
We offer you expert worldwide support for ensuring the best possible solutions for
outstanding performance. And with an extensive network of Global Service Partners, we also
provide you with comprehensive global service for all of our components.
Local address:
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products
already on order provided that such alterations can be made without subsequent changes being necessary in specifications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.