Danfoss PVBZ Data sheet

Data Sheet
Module with Shock Valve
PVBZ
The PVG 32 valve was originally launched on the market in 1988 with a range of high performance electrical actuators.
In the late nineties, the program was extended to also include new features such as low leak ports, special inlet sections and special electrohydraulic actuator options.
The special PVBZ load compensated module was developed for applications, where integrated pilot operated check valves in the work ports are required to limit the port leakage.
The newest of the PVBZ have integrated shock valve for removing any transient pressure spikes generated by the load.
The new PVBZ basic module can be mixed with basic modules PVB (with additional tank line T0) and offers the following features.
Features
Integrated shock/anti-cavitation valve (A- and B- port)
Pilot operated check (POC) valves in A/B ports
Load independent module (build in compensator)
Separated pilot pressure tank line (T0)
Can be combined with standard PVB modules (with T0)
BSP/UNF port thread options
Available spools
Only main spools with check valves can be used
4/3 versions in the flow range from 5– 100 l/min
4/4 versions with float in the flow range from 5–100 l/min
option mounted PVE/PVM not possible
PVBZ with shock valve code numbers
Port Description Code No.
G ½ BSP 11018390 7/8 - 14 UNF 11018391
Comprehensive technical literature online at powersolutions.danfoss.com
©
Danfoss | Jun 2016 L1117892 | AI00000126en-US0202 | 1
Technical Specifications
A B
V310328.B
Max. pressure Port P continuous, Port A/B 350 bar [5076 psi]
Port T static/dynamic 25/40 bar [362/580 psi]
Oil flow, rated Port A/B and P 180 l/min [47 US gal/min]
Port A/B max. recommended 100 l/min [26 US gal/min]
Spool travel Standard ±7 mm [±0.28 in]
Proportional range ±5 mm [±0,22 in]
Float position ±7.5 mm [±0.30 in] Max. internal leakage at 200 bar [2900 psi], 21 mm2/s A/BT / PO check valve and shock valve 6 cm3/min [0.36 in3/min] Oil temperature (inlet) Recommended 30 60°C [86 140°F]
Minimum -30 °C [-22 °F]
Maximum 90 °C [194 °F] Ambient temperature -30 60 °C [-22 140 °F] Oil viscosity Operating range 12 - 75 mm2/s [65 - 347 SUS]
Minimum 4 mm2/s [39 SUS]
Maximum 460 mm2/s [2128 SUS] Filtration, max. contamination (ISO 4406) 18/16/13
Schematic
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2 | © Danfoss | Jun 2016 L1117892 | AI00000126en-US0202
Loading...