Danfoss PSVP10-NCR Technical Information

Proportional Valves Technical Information
30
20
40
80
60
1
2
Flow Control, Non-Compensated, Normally Closed, Poppet
PSVP10-NCR
OPERATION
SPECIFICATIONS
DIMENSIONS
mm [in]
This is a non-compensated, normally-closed, pilot-operated, poppet-type, proportional flow-control. Controlled flow is from port 2 to 1.
THEORETICAL PERFORMANCE
Rated pressure 260 bar [3770 psi] Rated flow at 10 bar [150 psi]
55 l/min [14 US gal/min]
Leakage 6 drops/min @
rated pressure
Weight 0.54 kg [1.19 lb] Hysteresis 8% maximum Threshold current 0.8 A (12 VDC coil)
0.4 A (24 VDC coil)
Maximum control current
1.8 A (12 VDC coil)
0.9 A (24 VDC coil)
Cavity SDC10-2 Standard Coil M19P 22 Watt
US gal/min
30
25
20
15
10
5
0 (24 V) (12 V)
0
l/min
125
100
75
50
25
0
barpsi
26 cSt[121SUS]hyd.oil at 50°C [122 °F]
60
OperatingC
26 cSt[121SUS]hyd.oil@50°C[122°F]
0
00.6 1.8(A)
Pressuredro p
ur
ves
0.
1.2
0.6
.9 (A)
20 bar
SCHEMATIC
40
0
0
20
0
0
0
0
0
40
5
10
8060
15
20
100
25
12020
l/min.
US gal/min
Cross-sectional view
26mm
3-5 Nm [2.2-3.7bf*ft]
COIL NUTKIT P/N 173802188
COIL NOTSHOWN FORCLARITY
107.12 [4.22]
27 45-50Nm[33-37lbf*ft]
2
31.90 [1.26]
1
7/8-14 UNF2A
[Ø1.04]
Ø26.50
ORDERING INFORMATION
BC332375973113en-000101 • February 2020
PV - 31