Danfoss PSV10-NC Technical Information

Proportional Valves Technical Information
2
1
Flow Control, Non-Compensated, Normally Closed
PSV10-NC
OPERATION
SPECIFICATIONS
This is a normally-closed, direct-acting, spool-type, non-compensated, proportional flow-control. Controlled flow is from port 1 to 2.
Rated pressure 260 bar [3770 psi] Maximum flow at 10 bar [145 psi pressure drop]
Leakage 420 cm³/min [25.6 in³/min] @
Weight 0.51 kg [1.12 lb] Hysteresis 5% maximum Threshold current 0.5 A (12 VDC coil)
Maximum control current
Cavity SDC10-2 Standard Coil M19P 22 Watt
PSV10-NC-10: 10 l/min [2.64 US gal/min] PSV10-NC-25: 25 l/min [6.6 US gal/min] PSV10-NC-40: 40 l/min [10.6 US gal/min]
rated pressure
0.25 A (24 VDC coil)
1.8 A (12 VDC coil)
0.9 A (24 VDC coil)
THEORETICAL PERFORMANCE
SCHEMATIC
DIMENSIONS
mm [in]
ORDERING INFORMATION
Cross-sectional view
26mm
3-5 Nm [2.2-3.7bf•ft]
COIL NUTKIT P/N 173802188
COIL NOTSHOWN FORCLARITY
27 45-50Nm[33-37lbf•ft]
2
32.00 [1.26]
1
354004019
354003419
7/8-14 UNF2A
[Ø1.04]
Ø26.50
BC332375973113en-000101 • February 2020
* PB (Push-Button) available upon request