Danfoss PSV10-34-05 Technical Information

0 (0)
Danfoss PSV10-34-05 Technical Information

Proportional Valves Technical Information

Proportional Directional

PSV10-34-05

OPERATION

This is a proportional, non-compensated, 3 position 4 way, directional flow control solenoid valve, with float-center spool.

APPLICATION NOTES

These cartridge valves are typically applied to provide bi-directional, proportional control of hydraulic cylinders and motors. In applications requiring load-holding, PO checks or counterbalance valves can be added to provide a low leakage solution. For load-independent flow control, apply with a pressure compensator, such as CP700-4 (see Example Circuit). Port 1 should be used as the tank port, with a maximum backpressure of 150 bar. For applications with unequal flows, the highest flow should be connected to Port 2.

Note: For optimal performance install with the solenoid valve below the tank oil level in the horizontal position, reducing the chance for trapped air in the valve.

Shown with DIN connector,

Shown with Robust Coil

standard coil

 

SCHEMATIC

4

2

S1

S2

3

1

SPECIFICATIONS

Rated Pressure*

250 bar [3600 psi]

Maximum Rated Flow at 10 bar

22 l/min

[145 psi]

[6 US gal/min]

Weight including coil

0.77 kg [1.7 lbs]

Hysteresis

4% maximum

Threshold current

0.5 A (12 VDC coil)

 

0.25 A (24 VDC coil)

Maximum control current

1.5 A (12 VDC coil)

DIMENSIONS

0.8 A (24 VDC coil)

 

Cavity

SDC10-4

 

 

Standard Coil

M16 26 Watt

Robust Coil

R16 20 Watt

 

Robust Nut P/N 173804910

 

(no coil O-rings needed)

 

 

THEORETICAL PERFORMANCE

Operating curves with M16 coil and plastic nut

* Rated Pressure based on NFPA fatigue test standards (at 1 Million Cycles).

Operating curves with R16 coil and steel nut

BC332375973113en-000101 • February 2020