Danfoss PL35G Data sheet

PL35G Universal Compressor R134a 220-240V 50/60Hz
General
Code number 101G0251
Approvals UL984, EN 60335-2-34
Application
Application MBP/HBP
Frequency Hz 50 60
Evaporating temperature °C -25 to 15 -25 to 0
Voltage range V 198 - 254 198 - 254
Max. condensing temperature continuous (short) °C 60 (70) 60 (70)
Max. winding temperature continuous (short) °C 125 (135) 125 (135)
Cooling requirements
Frequency Hz 50 60
Application
32°C F2F2– F2–
38°C F
43°C
Remarks on application:
Motor
Motor type RSCR/CSIR
LRA (rated after 4 sec. UL984), HST | LST A 4.2 2.1
Cut in Current, HST | LST A 4.2 6.6
Resistance, main | start winding (25°C) 38.0 14.0
Design
Displacement cm
Oil quantity (type) cm
Maximum refrigerant charge g 300
Free gas volume in compressor cm
Weight without electrical equipment kg 4.3
Dimensions
Height mm A 137
Suction connector location/I.D. mm | angle C 6.5 | 41.5°
material | comment Cu-plated steel | Al cap
Process connector location/I.D. mm | angle D 6.5 | 45°
material | comment Cu-plated steel | Al cap
Discharge connector location/I.D. mm | angle E 5.0 | 21°
material | comment Cu-plated steel | Al cap
Oil cooler connector location/I.D. mm | angle F
material | comment
Connector tolerance I.D. mm ±0.09, on 5.0 +0.12/+0.20
Remarks:
LBP MBP HBP LBP MBP HBP
2F2
3
3
3
150 (polyolester)
B 135
B1 128
B2 73
F2–
2.00
850
S = Static cooling normally sufcient O = Oil cooling F1 = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) F2 = Fan cooling 3.0 m/s necessary SG = Suction gas cooling normally sufcent – = not applicable in this area
June 2012 Manufactured by Secop for Danfoss - DEHC.ED.401.K5.02 / 520N1347 1/2
EN 12900 Household (CECOMAF) 220V, 50Hz, fan cooling F
2
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 28.0 31.6 39.3 53.0 69.4 82.0 89.0 112 140 153 172 209
Power cons. in W 48.0 49.6 53.2 59.5 66.6 72.0 74.3 82.2 90.0 93.4 97.5 104
Current cons. in A 0.46 0.47 0.48 0.50 0.52 0.53 0.54 0.57 0.59 0.61 0.63 0.66
COP in W/W 0.58 0.64 0.74 0.89 1.04 1.14 1.20 1.37 1.55 1.64 1.76 2.00
ASHRAE LBP 220V, 50Hz, fan cooling F
2
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 34.5 39.0 48.5 65.4 85.8 102 110 139 173 190 213 260
Power cons. in W 48.0 49.6 53.2 59.5 66.6 72 74.3 82.2 90.0 93.4 97.5 104
Current cons. in A 0.46 0.47 0.48 0.50 0.52 0.53 0.54 0.57 0.59 0.61 0.63 0.66
COP in W/W 0.72 0.79 0.91 1.10 1.29 1.42 1.48 1.69 1.93 2.04 2.19 2.49
EN 12900 Household (CECOMAF) 220V, 60Hz, fan cooling F
2
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 34.0 38.5 47.9 63.8 82.3 96.0 104 129
Power cons. in W 51.5 54.8 61.0 70.2 79.1 88.0 87.8 96.4
Current cons. in A 0.43 0.43 0.44 0.45 0.47 0.48 0.49 0.51
COP in W/W 0.66 0.70 0.78 0.91 1.04 1.13 1.18 1.33
ASHRAE LBP 220V, 60Hz, fan cooling F
2
Evap. temp. in °C -45 -40 -35 -30 -25 -23.3 -20 -15 -10 -6.7 -5 0 5 7.2 10 15 20
Capacity in W 42.0 47.5 59.1 78.8 102 119 128 159
Power cons. in W 51.5 54.8 61.0 70.2 79.1 85.0 87.8 96.4
Current cons. in A 0.43 0.43 0.44 0.45 0.47 0.48 0.49 0.51
COP in W/W 0.82 0.87 0.97 1.12 1.29 1.41 1.46 1.65
Accessories for PL35G Figure Code number Test conditions EN 12900/
ASHRAE
CECOMAF
PTC starting device 6.3 mm spade connectors
4.8 mm spade connectors 103N0018 Ambient temperature 32°C 32°C
a1
103N0011 Condensing temperature 55°C 54.4°C
Starting relay 6.3 mm spade connectors a2 117U6021 Suction gas temperature 32°C 32°C
Start. capacitor 60 µF 6.3 mm spade connectors c 117U5014 Liquid temperature no subcooling 32°C
Cover b 103N0492
Cord relief d 103N1010 Mounting accessories Code number
Protection screen PTC g 103N0476 Bolt joint for one comp. Ø: 16 mm 118-1917
Bolt joint in quantities Ø: 1 6 mm 118-1918
Snap-on in quantities Ø : 16 mm 118-1919
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
2/2 Manufactured by Secop for Danfoss - DEHC.ED.401.K5.02 / 520N1347 June 2012
Loading...